Development And Validation Of A Sensitive Bioanalytical LC-MS/MS Method For Simultaneous Estimation Of Bisoprolol Fumarate And Cilnidipine In Human Plasma
International Journal of Drug Delivery Technology · 13.05.2026 · 16 (27s)
DOI: 10.25258/ijddt.16.27s.111 ↗Kurz gefasst
Fachartikel in der Zeitschrift International Journal of Drug Delivery Technology, online erschienen am 13.05.2026. Verfasst von Hitesh Raval und 6 weiteren Autor:innen.
Abstract (Originalsprache)
A highly sensitive, selective and robust LC-MS/MS bioanalytical technique was designed and tested to simultaneously determine Bisoprolol Fumarate (BISO) and Cilnidipine (CIL) in K2EDTA human plasma. Chromatographic separation was achieved using a Sapphirus C18 HP Classic column (150 × 4.6 mm, 5 µm) with a mobile phase consisting of 10 mM ammonium acetate and methanol (10:90, v/v). The detection of each analyte was performed using turbo ion spray (TIS) in positive ion mode with Multiple Reaction Monitoring (MRM). Benidipine hydrochloride was taken as an internal standard (ISTD). Preparation of the sample was performed through liquid-liquid extraction (LLE). The method was validated according to ICH M10 guidelines over the concentration range of 0.2–40 ng/mL for Bisoprolol fumarate (correlation coefficients (R2 ): 0.9993) and 0.1–20 ng/mL for Cilnidipine (correlation coefficients (R2 ): 0.9999). The method met all regulatory acceptance criteria for precision, accuracy, recovery, matrix effect, dilution integrity, and stability. The validated method is suitable for application in pharmacokinetic studies, as well as bioavailability and bioequivalence assessments.
Zitieren
APA
Raval, H., Kundu, V., Patel, D., Patel, S., Parmar, R., Thakkar, V., & Patel, G. (2026). Development And Validation Of A Sensitive Bioanalytical LC-MS/MS Method For Simultaneous Estimation Of Bisoprolol Fumarate And Cilnidipine In Human Plasma. International Journal of Drug Delivery Technology, 16(27s). https://doi.org/10.25258/ijddt.16.27s.111
Vancouver
Raval H, Kundu V, Patel D, Patel S, Parmar R, Thakkar V, et al. Development And Validation Of A Sensitive Bioanalytical LC-MS/MS Method For Simultaneous Estimation Of Bisoprolol Fumarate And Cilnidipine In Human Plasma. International Journal of Drug Delivery Technology. 2026;16(27s). doi:10.25258/ijddt.16.27s.111
BibTeX
@article{Raval2026,
author = {Raval, Hitesh and Kundu, Vijaylaxmi and Patel, Devanshi and Patel, Shreyaskumar and Parmar, Rajesh and Thakkar, Vedika and Patel, Gopi},
title = {Development And Validation Of A Sensitive Bioanalytical LC-MS/MS Method For Simultaneous Estimation Of Bisoprolol Fumarate And Cilnidipine In Human Plasma},
journal = {International Journal of Drug Delivery Technology},
year = {2026},
volume = {16},
number = {27s},
doi = {10.25258/ijddt.16.27s.111}
}
EUVIMED