Comparative analysis of experimental torque behavior and physicochemical properties of commercial and in‑house orthodontic aligners
Journal of the World Federation of Orthodontists · 2026
DOI: 10.1016/j.ejwf.2026.08.004 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Journal of the World Federation of Orthodontists, 2026. Verfasst von Gustavo Holderbaum und 3 weiteren Autor:innen. Beteiligte Einrichtung: Graduate in Biotechnology Program, National Institute of Metrology, Technology and Quality, Duque de Caxias, Rio de Janeiro, Brazil. Hauptthemen laut MEDLINE: Orthodontic Appliances, Removable, Orthodontic Appliance Design. Die Arbeit nennt 17 Literaturangaben.
Abstract (Originalsprache)
OBJECTIVES: Clear aligner performance depends on the magnitude and time-dependent behavior of experimentally generated moments. This study compared polymer identity, local post-thermoforming thickness, and experimental torque behavior of a commercial multilayer aligner (Invisalign) and two in-house thermoformed PETG aligners. METHODS: Ethical approval and consent were obtained. A digital scan from one patient was used to fabricate a standardized 3D-printed maxillary model. Three systems were evaluated: Invisalign (thermoplastic polyurethane [TPU]-based) and two vacuum-formed PETG systems (BioArt and Forestadent). Polymer identity was determined by ATR-FTIR. SEM assessed local thickness and morphology after thermoforming. Experimental torque, defined as mechanical moment (N·mm), was quantified using a setup programmed to produce a 0.3 mm displacement of the maxillary right central incisor. Short-term torque was recorded from 0 to 3 minutes (n = 5 per group) and analyzed using two-way repeated-measures ANOVA. Seven-day torque decay was monitored under dry, room-temperature conditions (n = 2 per group) and interpreted descriptively. RESULTS: ATR-FTIR confirmed PETG signatures for BioArt and Forestadent and TPU signatures for Invisalign. Thermoforming reduced local PETG thickness at tooth 11 by 58.6% for BioArt and 45.8% for Forestadent. At baseline and 3 minutes, Invisalign and Forestadent generated higher experimental torque than BioArt. Significant short-term torque reduction occurred for Invisalign and Forestadent, but not for BioArt. In the exploratory 7-day assessment, torque loss was 12.3%, 13.6%, and 20.2%, respectively. CONCLUSIONS: Material chemistry and local geometry influenced experimental torque magnitude and relaxation under in vitro conditions. Long-term findings were exploratory and require confirmation under clinically relevant conditions.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Graduate in Biotechnology Program, National Institute of Metrology, Technology and Quality, Duque de Caxias, Rio de Janeiro, Brazil.
- Mechanical Metrology Division, National Institute of Metrology, Technology and Quality, Duque de Caxias, Rio de Janeiro, Brazil.
- Regenerative Medicine Laboratory, UNIFASE, Petrópolis, Rio de Janeiro, Brazil. Electronic address: esthertakamori@prof.unifase-rj.edu.br.
- Graduate in Biotechnology Program, National Institute of Metrology, Technology and Quality, Duque de Caxias, Rio de Janeiro, Brazil; Metrology in Biology Division, National Institute of Metrology, Technology and Quality…
Zitieren
APA
Holderbaum, G., Beatrici, A., Takamori, E. R., & Granjeiro, J. M. (2026). Comparative analysis of experimental torque behavior and physicochemical properties of commercial and in‑house orthodontic aligners. Journal of the World Federation of Orthodontists. https://doi.org/10.1016/j.ejwf.2026.08.004
Vancouver
Holderbaum G, Beatrici A, Takamori ER, Granjeiro JM. Comparative analysis of experimental torque behavior and physicochemical properties of commercial and in‑house orthodontic aligners. Journal of the World Federation of Orthodontists. 2026. doi:10.1016/j.ejwf.2026.08.004
BibTeX
@article{Holderbaum2026,
author = {Holderbaum, Gustavo and Beatrici, Anderson and Takamori, Esther Rieko and Granjeiro, José Mauro},
title = {Comparative analysis of experimental torque behavior and physicochemical properties of commercial and in‑house orthodontic aligners},
journal = {Journal of the World Federation of Orthodontists},
year = {2026},
doi = {10.1016/j.ejwf.2026.08.004}
}