EUVIMEDEUVIMED entdecken
Übersichtsarbeit

Magnetic susceptibility source separation (χ-separation) in quantitative susceptibility mapping

Sadegh Ghaderi, Sana Mohammadi, Seyed-Mohammad Fereshtehnejad

Magnetic Resonance Imaging · 2026-10 · 132 · 110708

DOI: 10.1016/j.mri.2026.110708 ↗

Kurz gefasst

Übersichtsarbeit in der Zeitschrift Magnetic Resonance Imaging, 2026-10. Verfasst von Sadegh Ghaderi und 2 weiteren Autor:innen. Beteiligte Einrichtung: Neuromuscular Research Center, Department of Neurology, Shariati Hospital, Tehran University of Medical Sciences, Tehran, Iran; Department of Neurosc…. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Image Processing, Computer-Assisted, Brain, Brain Mapping. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 123 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Conventional quantitative susceptibility mapping (QSM) outputs a voxel-averaged value, frequently obscuring co-localized paramagnetic iron and diamagnetic myelin through phase cancellation. χ-separation resolves this ambiguity by disentangling sub-voxel magnetic sources to quantify specific biomarkers. This review categorizes separation methodologies into multi-sequence approaches utilizing R2 or R2' (e.g., SEMI-TWInS, APART-QSM) and clinically expedient gradient-recalled echo (GRE)-only techniques (e.g., DECOMPOSE-QSM, QSM-ARCS). We further evaluate deep learning frameworks, such as χ-sepnet, designed to synthesize missing relaxation parameters for direct source mapping. Analysis reveals a trajectory toward simplified acquisition protocols, yet accurate determination of relaxometric constants and adherence to static dephasing regime assumptions remain significant biophysical hurdles. While specificity for iron and myelin quantification is improved, the absence of a definitive in vivo gold standard complicates absolute accuracy assessment. Future implementation must prioritize anisotropy-aware modeling and robust ground-truth validation to ensure clinical viability.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Magnetic Resonance ImagingImage Processing, Computer-AssistedBrainBrain MappingHumansDeep LearningIronMyelin SheathAlgorithmsAnisotropy

Stichwörter der Autor:innen

Deep learningDiamagnetic susceptibilityNeurodegenerative diseasesParamagnetic susceptibilityQuantitative susceptibility mappingΧ-Separation

Substanzen

Iron

Autor:innen und Institutionen

  • Neuromuscular Research Center, Department of Neurology, Shariati Hospital, Tehran University of Medical Sciences, Tehran, Iran; Department of Neuroscience and Addiction Studies, School of Advanced Technologies in Medici…
  • Neuromuscular Research Center, Department of Neurology, Shariati Hospital, Tehran University of Medical Sciences, Tehran, Iran; Department of Medical Sciences, School of Medicine, Iran University of Medical Sciences, Te…
  • Pacific Parkinson's Research Centre (PPRC), Djavad Mowafaghian Centre for Brain Health, University of British Columbia, Vancouver, BC, Canada; Division of Neurology, Faculty of Medicine, University of British Columbia,…

Zitieren

APA

Ghaderi, S., Mohammadi, S., & Fereshtehnejad, S. M. (2026). Magnetic susceptibility source separation (χ-separation) in quantitative susceptibility mapping. Magnetic Resonance Imaging, 132, 110708. https://doi.org/10.1016/j.mri.2026.110708

Vancouver

Ghaderi S, Mohammadi S, Fereshtehnejad SM. Magnetic susceptibility source separation (χ-separation) in quantitative susceptibility mapping. Magnetic Resonance Imaging. 2026;132:110708. doi:10.1016/j.mri.2026.110708

BibTeX
@article{Ghaderi2026,
  author = {Ghaderi, Sadegh and Mohammadi, Sana and Fereshtehnejad, Seyed-Mohammad},
  title = {Magnetic susceptibility source separation (χ-separation) in quantitative susceptibility mapping},
  journal = {Magnetic Resonance Imaging},
  year = {2026},
  volume = {132},
  pages = {110708},
  doi = {10.1016/j.mri.2026.110708}
}
Kostenlos starten →