EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Incorporating functional soft tissue deformations in AI model training for spatially accurate prostate cancer detection

Balint Kovacs, Kevin Sun Zhang, Michael Baumgartner, Thomas Hielscher, Dimitrios Bounias, Nils Netzer, Ralf Floca, Carolin Eith, Paul F Jäger, Clara Meinzer, Fabian Isensee, Regula Gnirs und 7 weitere

Magnetic Resonance Imaging · 2026-09 · 131 · 110698

DOI: 10.1016/j.mri.2026.110698 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance Imaging, 2026-09. Verfasst von Balint Kovacs und 18 weiteren Autor:innen. Beteiligte Einrichtung: German Cancer Research Center (DKFZ) Heidelberg, Division of Medical Image Computing, Heidelberg, Germany; DKFZ Heidelberg, Division of Radiology, He…. Hauptthemen laut MEDLINE: Image Interpretation, Computer-Assisted, Prostatic Neoplasms, Artificial Intelligence. Die Arbeit nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: DFG, DKFZ, BMWK.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: To increase performance and generalization ability of artificial intelligence prostate cancer detection systems by simulating physiological size changes of the bladder and rectum and, thereby, associated deformations of the prostate and its lesions. MATERIALS AND METHODS: This retrospective study included 1028 bi-parametric MRI examinations of men (age range: 40-90 years) performed between 2014 and 2019, divided into training/test sets (771/257). We integrated an 'anatomy-informed' transformation into the training of nnU-Net, by simulating soft-tissue deformations of the prostate resulting from size changes of the rectum and bladder. The effects of these strategies were evaluated using free-response receiver operating characteristic (FROC) to assess lesion-level performance, along with a variant: weighted alternative FROC (wAFROC), which prioritizes patient-level effects with localization criteria. Change in sensitivity was tested using a clustered McNemar test. Patient-level performance was assessed with standard and localized receiver operating characteristics (ROC/LROC) analysis. RESULTS: On the independent test set, the anatomy-informed model simulating changes of both rectum and bladder significantly increased lesion-level detection of true positive lesions by 18.8% (from 48 to 57, p = 0.01) and demonstrated significantly higher performance in the wAFROC analysis (from 0.597 to 0.639, p < 0.01). Patient-level ROC increased slightly (from 0.779 to 0.782, p = 0.89), while LROC analysis demonstrated increased performance (from 0.471 to 0.546). CONCLUSION: Simulation of rectum and bladder size variations during model training led to significant improvement in lesion detection performance, which may be crucial for diagnostics and therapeutic measures depending on correct lesion localization, e.g. MRI-guided biopsies or focal therapy regimes.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Image Interpretation, Computer-AssistedProstatic NeoplasmsArtificial IntelligenceComputer SimulationMagnetic Resonance ImagingRectumROC CurveUrinary BladderSensitivity and SpecificityRetrospective StudiesHumansMaleFemale

Autor:innen und Institutionen

  • German Cancer Research Center (DKFZ) Heidelberg, Division of Medical Image Computing, Heidelberg, Germany; DKFZ Heidelberg, Division of Radiology, Heidelberg, Germany; Medical Faculty Heidelberg, Heidelberg University,…
  • DKFZ Heidelberg, Division of Radiology, Heidelberg, Germany.
  • German Cancer Research Center (DKFZ) Heidelberg, Division of Medical Image Computing, Heidelberg, Germany; Faculty of Mathematics and Computer Science, Heidelberg University, Heidelberg, Germany; DKFZ Heidelberg, Helmho…
  • DKFZ Heidelberg, Division of Statistics, Heidelberg, Germany.
  • German Cancer Research Center (DKFZ) Heidelberg, Division of Medical Image Computing, Heidelberg, Germany; Medical Faculty Heidelberg, Heidelberg University, Heidelberg, Germany.
  • DKFZ Heidelberg, Division of Radiology, Heidelberg, Germany; Medical Faculty Heidelberg, Heidelberg University, Heidelberg, Germany.

Förderung

  • DFG
  • DKFZ
  • BMWK

Zitieren

APA

Kovacs, B., Zhang, K. S., Baumgartner, M., Hielscher, T., Bounias, D., Netzer, N., Floca, R., Eith, C., Jäger, P. F., Meinzer, C., Isensee, F., Gnirs, R., Görtz, M., Hohenfellner, M., Stenzinger, A., Schlemmer, H. P., Wolf, I., Maier-Hein, K. H., & Bonekamp, D. (2026). Incorporating functional soft tissue deformations in AI model training for spatially accurate prostate cancer detection. Magnetic Resonance Imaging, 131, 110698. https://doi.org/10.1016/j.mri.2026.110698

Vancouver

Kovacs B, Zhang KS, Baumgartner M, Hielscher T, Bounias D, Netzer N, et al. Incorporating functional soft tissue deformations in AI model training for spatially accurate prostate cancer detection. Magnetic Resonance Imaging. 2026;131:110698. doi:10.1016/j.mri.2026.110698

BibTeX
@article{Kovacs2026,
  author = {Kovacs, Balint and Zhang, Kevin Sun and Baumgartner, Michael and Hielscher, Thomas and Bounias, Dimitrios and Netzer, Nils and Floca, Ralf and Eith, Carolin and Jäger, Paul F and Meinzer, Clara and Isensee, Fabian and Gnirs, Regula and Görtz, Magdalena and Hohenfellner, Markus and Stenzinger, Albrecht and Schlemmer, Heinz-Peter and Wolf, Ivo and Maier-Hein, Klaus H and Bonekamp, David},
  title = {Incorporating functional soft tissue deformations in AI model training for spatially accurate prostate cancer detection},
  journal = {Magnetic Resonance Imaging},
  year = {2026},
  volume = {131},
  pages = {110698},
  doi = {10.1016/j.mri.2026.110698}
}
Kostenlos starten →