EUVIMEDEUVIMED entdecken
Crossref

Artificial Intelligence Quantification of Enhanced Synovium Throughout the Entire Hand in Rheumatoid Arthritis on Dynamic Contrast‐Enhanced MRI

Yijun Mao, Kiko Imahori, Wanxuan Fang, Hiroyuki Sugimori, Shinji Kiuch, Kenneth Sutherland, Tamotsu Kamishima iD

Journal of Magnetic Resonance Imaging · 2025

DOI: 10.1002/jmri.29463 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Magnetic Resonance Imaging, 2025. Verfasst von Yijun Mao und 6 weiteren Autor:innen. Beteiligte Einrichtung: Graduate School of Health Sciences, Hokkaido University, Sapporo, Hokkaido, Japan. Hauptthemen laut MEDLINE: Arthritis, Rheumatoid, Magnetic Resonance Imaging, Contrast Media, Artificial Intelligence. Die Arbeit wurde bisher 14-mal zitiert (Crossref) und nennt 40 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Challenges persist in achieving automatic and efficient inflammation quantification using dynamic contrast‐enhanced (DCE) MRI in rheumatoid arthritis (RA) patients.

Purpose

To investigate an automatic artificial intelligence (AI) approach and an optimized dynamic MRI protocol for quantifying disease activity in RA in whole hands while excluding arterial pixels. Study Type Retrospective. Subjects Twelve RA patients underwent DCE‐MRI with 27 phases for creating the AI model and tested on images with a variable number of phases from 35 RA patients. Field Strength/Sequence 3.0 T/DCE T1‐weighted gradient echo sequence (mDixon, water image). Assessment The model was trained with various DCE‐MRI time‐intensity number of phases. Evaluations were conducted for similarity between AI segmentation and manual outlining in 51 ROIs with synovitis. The relationship between synovial volume via AI segmentation with rheumatoid arthritis magnetic resonance imaging scoring (RAMRIS) across whole hands was then evaluated. The reference standard was determined by an experienced musculoskeletal radiologist. Statistical Test Area under the curve (AUC) of receiver operating characteristic (ROC), Dice and Spearman's rank correlation coefficients, and interclass correlation coefficient (ICC). A P ‐value

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthritis, RheumatoidMagnetic Resonance ImagingContrast MediaArtificial IntelligenceSynovial MembraneHandHumansFemaleMaleMiddle AgedRetrospective StudiesAgedAdultSynovitisROC CurveImage Interpretation, Computer-AssistedImage Processing, Computer-Assisted

Stichwörter der Autor:innen

artificial intelligencedynamic contrast‐enhanced MRIone‐dimensional time‐intensity datarheumatoid arthritis

Substanzen

Contrast Media

Autor:innen und Institutionen

  • Graduate School of Health Sciences, Hokkaido University, Sapporo, Hokkaido, Japan.
  • Faculty of Health Sciences, Hokkaido University, Sapporo, Hokkaido, Japan.
  • AIC Yaesu Clinic, Tokyo, Japan.
  • Global Center for Biomedical Science and Engineering, Hokkaido University, Sapporo, Hokkaido, Japan.

ORCID-Profile: Tamotsu Kamishima

Zitieren

APA

Mao, Y., Imahori, K., Fang, W., Sugimori, H., Kiuch, S., Sutherland, K., & Kamishima, T. (2025). Artificial Intelligence Quantification of Enhanced Synovium Throughout the Entire Hand in Rheumatoid Arthritis on Dynamic Contrast‐Enhanced MRI. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.29463

Vancouver

Mao Y, Imahori K, Fang W, Sugimori H, Kiuch S, Sutherland K, et al. Artificial Intelligence Quantification of Enhanced Synovium Throughout the Entire Hand in Rheumatoid Arthritis on Dynamic Contrast‐Enhanced MRI. Journal of Magnetic Resonance Imaging. 2025. doi:10.1002/jmri.29463

BibTeX
@article{Mao2025,
  author = {Mao, Yijun and Imahori, Kiko and Fang, Wanxuan and Sugimori, Hiroyuki and Kiuch, Shinji and Sutherland, Kenneth and Kamishima, Tamotsu},
  title = {Artificial Intelligence Quantification of Enhanced Synovium Throughout the Entire Hand in Rheumatoid Arthritis on Dynamic Contrast‐Enhanced MRI},
  journal = {Journal of Magnetic Resonance Imaging},
  year = {2025},
  doi = {10.1002/jmri.29463}
}