Advancing high-resolution 7 T diffusion MRI: Evaluating phase-encoding correction strategies for distortion correction from basic to four-way acquisitions
Magnetic Resonance Imaging · 2026-09 · 131 · 110694
DOI: 10.1016/j.mri.2026.110694 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance Imaging, 2026-09. Verfasst von Kurt G Schilling und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology & Radiological Science, Vanderbilt University Medical Center, Nashville, TN, USA. Electronic address: kurt.g.schilling.1@vumc…. Hauptthemen laut MEDLINE: Diffusion Magnetic Resonance Imaging, Image Processing, Computer-Assisted, Brain, Image Enhancement. Die Arbeit nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NINDS NIH HHS, NIMH NIH HHS, NIBIB NIH HHS.
Abstract (Originalsprache)
PURPOSE: High-resolution 7 T diffusion MRI (dMRI) is limited by image artifacts that compromise anatomical accuracy. The purpose of this study was to systematically evaluate phase-encoding (PE) acquisition and correction strategies to determine which methods best mitigate geometric distortions and improve data reproducibility. METHODS: Five healthy adults were each scanned twice on the NexGen 7 T MRI scanner with ultra-high performance gradients at 0.9 mm isotropic resolution, using a highly oversampled dMRI protocol with four PE directions (AP, PA, RL, LR). From this dataset, we created and processed eleven time-equivalent, 10-min acquisitions, ranging from uncorrected single-PE data to comprehensive 4-way PE schemes. These strategies were quantitatively compared on their geometric alignment with T1-weighted images and on the scan-rescan reproducibility of DTI-derived metrics. RESULTS: (1) All distortion-corrected schemes significantly improved geometric accuracy over uncorrected data; (2) Strategies correcting with a full set of reversed-PE (2-way) diffusion weighted images (DWIs) outperformed the common approach of using only a single reversed b = 0 image; and (3) a 4-way PE acquisition consistently provided the highest image fidelity and reproducibility. The optimized acquisition enabled high-quality reconstruction of both long-range and fine-scale superficial white matter pathways. CONCLUSION: For high-resolution 7 T dMRI, multi-PE acquisition is essential to achieve accurate geometry and stable microstructural estimates (i.e., less residual EPI distortion and better scan-rescan agreement). A 4-way PE scheme provides the most accurate and reproducible results for microstructural and connectivity modeling.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiology & Radiological Science, Vanderbilt University Medical Center, Nashville, TN, USA. Electronic address: kurt.g.schilling.1@vumc.org.
- Helen Wills Neuroscience Institute, University of California, Berkeley, Berkeley, CA, USA; Advanced MRI Technologies, Sebastopol, CA, USA.
- Department of Radiology & Radiological Science, Vanderbilt University Medical Center, Nashville, TN, USA.
- Helen Wills Neuroscience Institute, University of California, Berkeley, Berkeley, CA, USA.
- Helen Wills Neuroscience Institute, University of California, Berkeley, Berkeley, CA, USA; Department of Psychology, University of California, Berkeley, Berkeley, CA, USA.
- Radiology and Biomedical Imaging, University of California, San Francisco, San Francisco, CA, USA; Radiology, San Francisco Veteran Affairs Health Care System, San Francisco, CA, USA.
Förderung
- NINDS NIH HHS
- NIMH NIH HHS
- NIBIB NIH HHS
- National Institutes of Health
Zitieren
APA
Schilling, K. G., Beckett, A. J. S., Amandola, M., Walker, E. B., Feinberg, D. A., Bunge, S. A., & Vu, A. T. (2026). Advancing high-resolution 7 T diffusion MRI: Evaluating phase-encoding correction strategies for distortion correction from basic to four-way acquisitions. Magnetic Resonance Imaging, 131, 110694. https://doi.org/10.1016/j.mri.2026.110694
Vancouver
Schilling KG, Beckett AJS, Amandola M, Walker EB, Feinberg DA, Bunge SA, et al. Advancing high-resolution 7 T diffusion MRI: Evaluating phase-encoding correction strategies for distortion correction from basic to four-way acquisitions. Magnetic Resonance Imaging. 2026;131:110694. doi:10.1016/j.mri.2026.110694
BibTeX
@article{Schilling2026,
author = {Schilling, Kurt G and Beckett, Alexander J S and Amandola, Matthew and Walker, Erica B and Feinberg, David A and Bunge, Silvia A and Vu, An T},
title = {Advancing high-resolution 7 T diffusion MRI: Evaluating phase-encoding correction strategies for distortion correction from basic to four-way acquisitions},
journal = {Magnetic Resonance Imaging},
year = {2026},
volume = {131},
pages = {110694},
doi = {10.1016/j.mri.2026.110694}
}
EUVIMED