EUVIMEDEUVIMED entdecken
Crossref

R-index: A robust metric for IVIM parameter estimation on clinical MRI scanners

Yan Dai, Xun Jia, Yen-Peng Liao, Deng Jie

Magnetic Resonance Imaging · 2026

DOI: 10.1016/j.mri.2025.110560 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance Imaging, 2026. Verfasst von Yan Dai und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, TX, USA. Hauptthemen laut MEDLINE: Signal-To-Noise Ratio, Brain Neoplasms. Die Arbeit nennt 48 Literaturangaben. Gefördert von: NIBIB NIH HHS, NCI NIH HHS, University of Texas Southwestern Medical Center.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: Intravoxel Incoherent Motion (IVIM) model characterizes both water diffusion and perfusion in tissues, providing quantitative biomarkers valuable for tumor characterization. However, parameter estimation through nonlinear fitting of this bi-exponential model is challenging for its ill-posed nature, resulting in poor reproducibility, particularly at low signal to noise ratios (SNRs) in a clinic scenario. This study analyzes the uncertainty of IVIM model fitting, quantifies parameter collinearity, and introduces a new index with enhanced robustness to enhance clinical applicability of the IVIM model. METHODS: The probability distributions of estimated IVIM parameters were evaluated across a clinically relevant range. Collinearity among parameters was assessed and a metric, R-index, was proposed. The R-index linearly combines individual IVIM parameters to mitigate collinearity and reduce estimation uncertainty. Simulation, volunteer, and patient studies were conducted to validate the presence of parameter collinearity and to assess the robustness of the R-index. RESULTS: In simulations under typical clinical conditions (SNR = 20), normalized IVIM parameters exhibited mean standard deviations (Std) of 0.107-0.269 and the expected mean Std for R was 0.120, whereas the R-index showed a lower Std of 0.064. Same-day repeat scans in a healthy volunteer (1.5 T MRI) and multi-day scans in six brain tumor patients (1.5 T MR-Linac) confirmed parameter collinearity: Across the volunteer and patients, the mean Std of R-index was lower than the expected mean Std assuming independence between individual IVIM parameters. CONCLUSIONS: The R-index provides a robust metric for IVIM model fitting under low SNR in typical clinical conditions, offering improved reproducibility and potential for broader clinical applicability.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Signal-To-Noise RatioBrain NeoplasmsMagnetic Resonance ImagingMotionPhantoms, ImagingImage Processing, Computer-AssistedAlgorithmsHumansReproducibility of Results

Stichwörter der Autor:innen

Intravoxel incoherent motion modelModel fittingQuantitative MRIRobustness

Autor:innen und Institutionen

  • Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, TX, USA.
  • Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Baltimore, MD, USA.
  • Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, TX, USA. Electronic address: Jie.Deng@UTSouthwestern.edu.

Förderung

  • NIBIB NIH HHS
  • NCI NIH HHS
  • University of Texas Southwestern Medical Center
  • NIH

Zitieren

APA

Dai, Y., Jia, X., Liao, Y. P., & Jie, D. (2026). R-index: A robust metric for IVIM parameter estimation on clinical MRI scanners. Magnetic Resonance Imaging. https://doi.org/10.1016/j.mri.2025.110560

Vancouver

Dai Y, Jia X, Liao YP, Jie D. R-index: A robust metric for IVIM parameter estimation on clinical MRI scanners. Magnetic Resonance Imaging. 2026. doi:10.1016/j.mri.2025.110560

BibTeX
@article{Dai2026,
  author = {Dai, Yan and Jia, Xun and Liao, Yen-Peng and Jie, Deng},
  title = {R-index: A robust metric for IVIM parameter estimation on clinical MRI scanners},
  journal = {Magnetic Resonance Imaging},
  year = {2026},
  doi = {10.1016/j.mri.2025.110560}
}