EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

End-to-End Deep Learning-Based Motion Correction and Reconstruction for Accelerated Whole-Heart Joint T1/T2 Mapping

Lina Felsner, Carlos Velasco, Andrew Phair, Thomas J Fletcher, Haikun Qi, René M Botnar, Claudia Prieto

Magnetic Resonance Imaging · 2025

DOI: 10.1016/j.mri.2025.110396 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance Imaging, 2025. Verfasst von Lina Felsner und 6 weiteren Autor:innen. Beteiligte Einrichtung: School of Biomedical Engineering and Imaging Science, King's College London, London, United Kingdom. Hauptthemen laut MEDLINE: Deep Learning, Heart, Image Processing, Computer-Assisted, Magnetic Resonance Imaging. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: To accelerate 3D whole-heart joint T1/T2 mapping for myocardial tissue characterization using an end-to-end deep learning algorithm for joint motion estimation and model-based motion-corrected reconstruction of multi-contrast undersampled data. METHODS: A free-breathing high-resolution motion-compensated 3D joint T1/T2 water/fat sequence is employed. The sequence consists of the acquisition of four interleaved volumes with 2-echo encoding, resulting in eight volumes with different contrasts. An end-to-end non-rigid motion-corrected reconstruction network is used to estimate high quality motion-corrected reconstructions from the eight multi-contrast undersampled data for subsequent joint T1/T2 mapping. Reconstruction with the proposed approach was compared against state-of-the-art motion-corrected HD-PROST reconstruction. RESULTS: The proposed approach yields images with good visual agreement compared to the reference reconstructions. The comparison of the quantitative values in the T1 and T2 maps showed the absence of systematic errors, and a small bias of -6.35 ms and -1.8 ms, respectively. The proposed reconstruction time was 24 seconds in comparison to 2.5 hours with motion-corrected HD-PROST, resulting in a reconstruction speed-up of over 370 times. CONCLUSION: In conclusion, this study presents a promising method for efficient whole-heart myocardial tissue characterization. Specifically, the research highlights the potential of the multi-contrast end-to-end deep learning algorithm for joint motion estimation and model-based motion-corrected reconstruction of multi-contrast undersampled data. The findings underscore its ability to compute T1 and T2 values with good agreement when compared to the reference motion-corrected HD-PROST method, while substantially reducing reconstruction time.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Deep LearningHeartImage Processing, Computer-AssistedMagnetic Resonance ImagingHumansAlgorithmsImaging, Three-DimensionalMotion

Stichwörter der Autor:innen

End-to-end deep learning reconstructionMotion-correctionMyocardial tissue characterizationWhole-heart joint T(1)/T(2) mapping

Autor:innen und Institutionen

  • School of Biomedical Engineering and Imaging Science, King's College London, London, United Kingdom.
  • School of Biomedical Engineering, ShanghaiTech University, Shanghai, China.
  • School of Biomedical Engineering and Imaging Science, King's College London, London, United Kingdom; School of Engineering, Pontificia Universidad Católica de Chile, Santiago, Chile; Institute for Biological and Biomedi…

Zitieren

APA

Felsner, L., Velasco, C., Phair, A., Fletcher, T. J., Qi, H., Botnar, R. M., & Prieto, C. (2025). End-to-End Deep Learning-Based Motion Correction and Reconstruction for Accelerated Whole-Heart Joint T1/T2 Mapping. Magnetic Resonance Imaging. https://doi.org/10.1016/j.mri.2025.110396

Vancouver

Felsner L, Velasco C, Phair A, Fletcher TJ, Qi H, Botnar RM, et al. End-to-End Deep Learning-Based Motion Correction and Reconstruction for Accelerated Whole-Heart Joint T1/T2 Mapping. Magnetic Resonance Imaging. 2025. doi:10.1016/j.mri.2025.110396

BibTeX
@article{Felsner2025,
  author = {Felsner, Lina and Velasco, Carlos and Phair, Andrew and Fletcher, Thomas J and Qi, Haikun and Botnar, René M and Prieto, Claudia},
  title = {End-to-End Deep Learning-Based Motion Correction and Reconstruction for Accelerated Whole-Heart Joint T1/T2 Mapping},
  journal = {Magnetic Resonance Imaging},
  year = {2025},
  doi = {10.1016/j.mri.2025.110396}
}
Kostenlos starten →