Blip-up blip-down circular EPI (BUDA-cEPI) for distortion-free dMRI with rapid unrolled deep learning reconstruction
Magnetic Resonance Imaging · 2025
DOI: 10.1016/j.mri.2024.110277 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance Imaging, 2025. Verfasst von Uten Yarach und 11 weiteren Autor:innen. Beteiligte Einrichtung: Radiologic Technology Department, Associated Medical Sciences, Chiang Mai University, Chiang Mai, Thailand. Hauptthemen laut MEDLINE: Deep Learning, Image Processing, Computer-Assisted, Brain. Die Arbeit nennt 74 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIBIB NIH HHS, NIMH NIH HHS.
Abstract (Originalsprache)
PURPOSE: BUDA-cEPI has been shown to achieve high-quality, high-resolution diffusion magnetic resonance imaging (dMRI) with fast acquisition time, particularly when used in conjunction with S-LORAKS reconstruction. However, this comes at a cost of more complex reconstruction that is computationally prohibitive. In this work we develop rapid reconstruction pipeline for BUDA-cEPI to pave the way for its deployment in routine clinical and neuroscientific applications. The proposed reconstruction includes the development of ML-based unrolled reconstruction as well as rapid ML-based B0 and eddy current estimations that are needed. The architecture of the unroll network was designed so that it can mimic S-LORAKS regularization well, with the addition of virtual coil channels. METHODS: BUDA-cEPI RUN-UP - a model-based framework that incorporates off-resonance and eddy current effects was unrolled through an artificial neural network with only six gradient updates. The unrolled network alternates between data consistency (i.e., forward BUDA-cEPI and its adjoint) and regularization steps where U-Net plays a role as the regularizer. To handle the partial Fourier effect, the virtual coil concept was also introduced into the reconstruction to effectively take advantage of the smooth phase prior and trained to predict the ground-truth images obtained by BUDA-cEPI with S-LORAKS. RESULTS: The introduction of the Virtual Coil concept into the unrolled network was shown to be key to achieving high-quality reconstruction for BUDA-cEPI. With the inclusion of an additional non-diffusion image (b-value = 0 s/mm2), a slight improvement was observed, with the normalized root mean square error further reduced by approximately 5 %. The reconstruction times for S-LORAKS and the proposed unrolled networks were approximately 225 and 3 s per slice, respectively. CONCLUSION: BUDA-cEPI RUN-UP was shown to reduce the reconstruction time by ∼88× when compared to the state-of-the-art technique, while preserving imaging details as demonstrated through DTI application.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Radiologic Technology Department, Associated Medical Sciences, Chiang Mai University, Chiang Mai, Thailand.
- National Nanotechnology Center, National Science and Technology Development Agency, Pathum Thani, Thailand.
- Department of Radiology, Stanford University, Stanford, CA, USA; Department of Electrical Engineering, Stanford University, Stanford, CA, USA.
- Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, Cambridge, MA, USA.
- Department of Computer Engineering, Hongik University, Seoul, South Korea.
- Signal and Image Processing Institute, Ming Hsieh Department of Electrical and Computer Engineering, University of Southern California, Los Angeles, CA, USA.
Förderung
- NIBIB NIH HHS
- NIMH NIH HHS
Zitieren
APA
Yarach, U., Chatnuntawech, I., Liao, C., Teerapittayanon, S., Iyer, S. S., Kim, T. H., Haldar, J., Cho, J., Bilgic, B., Hu, Y., Hargreaves, B., & Setsompop, K. (2025). Blip-up blip-down circular EPI (BUDA-cEPI) for distortion-free dMRI with rapid unrolled deep learning reconstruction. Magnetic Resonance Imaging. https://doi.org/10.1016/j.mri.2024.110277
Vancouver
Yarach U, Chatnuntawech I, Liao C, Teerapittayanon S, Iyer SS, Kim TH, et al. Blip-up blip-down circular EPI (BUDA-cEPI) for distortion-free dMRI with rapid unrolled deep learning reconstruction. Magnetic Resonance Imaging. 2025. doi:10.1016/j.mri.2024.110277
BibTeX
@article{Yarach2025,
author = {Yarach, Uten and Chatnuntawech, Itthi and Liao, Congyu and Teerapittayanon, Surat and Iyer, Siddharth Srinivasan and Kim, Tae Hyung and Haldar, Justin and Cho, Jaejin and Bilgic, Berkin and Hu, Yuxin and Hargreaves, Brian and Setsompop, Kawin},
title = {Blip-up blip-down circular EPI (BUDA-cEPI) for distortion-free dMRI with rapid unrolled deep learning reconstruction},
journal = {Magnetic Resonance Imaging},
year = {2025},
doi = {10.1016/j.mri.2024.110277}
}
EUVIMED