EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY 4.0

Imaging of the renal allograft vasculature without gadolinium contrast: Intraindividual comparison between relaxation-enhanced angiography without contrast and triggering (REACT) and 4D contrast-enhanced MR-angiography

Carsten Gietzen, Juliana Tristram, Jan Paul Janssen, Marielle Hummels, Johannes Bremm, Kenan Kaya, Thorsten Gietzen, Henry Pennig, Roman Gertz, Thorsten Persigehl, Dirk Stippel, Kilian Weiss und 1 weitere

Magnetic Resonance Imaging · 2025

DOI: 10.1016/j.mri.2025.110423 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Magnetic Resonance Imaging, 2025. Verfasst von Carsten Gietzen und 12 weiteren Autor:innen. Beteiligte Einrichtung: Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany. …. Hauptthemen laut MEDLINE: Magnetic Resonance Angiography, Kidney Transplantation, Imaging, Three-Dimensional, Kidney. Die Arbeit nennt 47 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Medizinische Fakultät, Universität zu Köln.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Complications after kidney transplantation include transplant renal artery stenosis (TRAS), which can be assessed using Doppler ultrasonography, computed tomography angiography, and magnetic resonance angiography (MRA). Contrast-enhanced MRA (CE-MRA) has limitations, including potential allergic reactions, limited use in kidney failure, and uncertain long-term effects of gadolinium retention. PURPOSE: To evaluate Relaxation-Enhanced Angiography without Contrast and Triggering (REACT), a novel 3D isotropic flow-independent non-CE-MRA pulse sequence, for imaging of the renal allograft vasculature by performing an intraindividual comparison to 4D CE-MRA at 3Tesla. METHODS: Forty studies of 39 patients were included in this retrospective, single-centre study. Two board-certified radiologists independently evaluated MRA datasets for TRAS and rated their diagnostic confidence and the image quality of pelvic vessels using 5-point Likert scales (5 = excellent). Apparent signal- and contrast-to-noise ratios (aSNR/aCNR) were measured for arterial and venous graft vessels. RESULTS: REACT (median acquisition time 04:33 min [IQR 3:58-5:20 min]) showed 90.0 % sensitivity and 100.0 % specificity for TRAS in almost perfect agreement (r = 0.97) with 4D CE-MRA (03:41 min [3:38-4:46 min], p = 0.001) and similar diagnostic confidence (REACT: 4.0 [4.0-4.0] vs. 4D CE-MRA: 4.0 [3.0-4.0], p = 0.54). Arterial image quality was comparable (4.0 [3.7-4.4] vs. 4.0 [4.0-4.4], p = 0.49) whereas veins yielded higher scores in REACT (3.2 [3.0-3.5] vs. 2.4 [2.0-3.0], p < 0.001). Transplant renal artery (mean ± SD; 44.5 ± 18.2 vs. 45.9 ± 21.0, p = 0.71; 36.3 ± 15.0 vs. 41.0 ± 20.0, p = 0.16) and vein (37.1 ± 19.8 vs. 30.3 ± 15.2, p = 0.06; 29.4 ± 17.1 vs. 25.0 ± 14.7, p = 0.17) showed no difference in aSNR and aCNR. CONCLUSION: REACT provides accurate detection of TRAS with image quality comparable to 4D CE-MRA, offering a risk-free alternative for imaging after renal transplantation.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Magnetic Resonance AngiographyKidney TransplantationImaging, Three-DimensionalKidneyAllograftsRenal Artery ObstructionHumansMaleFemaleContrast MediaMiddle AgedRetrospective StudiesAdultGadoliniumRenal ArteryAgedReproducibility of Results

Stichwörter der Autor:innen

Contrast-enhanced magnetic resonance angiographyPelvic arteries and veinsRelaxation-enhanced angiography without contrast and triggeringRenal allograft vasculatureTransplant renal artery stenosis

Substanzen

Contrast MediaGadolinium

Autor:innen und Institutionen

  • Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany. Electronic address: Carsten.gietzen@uk-koeln.de.
  • Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany.
  • Department of General, Visceral, Cancer and Transplant Surgery, Faculty of Medicine and University Hospital of Cologne, University of Cologne, Cologne, Germany.
  • Department of Cardiology, Heart Center, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany.
  • Department of Orthopedics and Trauma Surgery, University Hospital Bonn, Bonn, Germany.
  • Philips GmbH, Hamburg, Germany.

Förderung

  • Medizinische Fakultät, Universität zu Köln

Zitieren

APA

Gietzen, C., Tristram, J., Janssen, J. P., Hummels, M., Bremm, J., Kaya, K., Gietzen, T., Pennig, H., Gertz, R., Persigehl, T., Stippel, D., Weiss, K., & Pennig, L. (2025). Imaging of the renal allograft vasculature without gadolinium contrast: Intraindividual comparison between relaxation-enhanced angiography without contrast and triggering (REACT) and 4D contrast-enhanced MR-angiography. Magnetic Resonance Imaging. https://doi.org/10.1016/j.mri.2025.110423

Vancouver

Gietzen C, Tristram J, Janssen JP, Hummels M, Bremm J, Kaya K, et al. Imaging of the renal allograft vasculature without gadolinium contrast: Intraindividual comparison between relaxation-enhanced angiography without contrast and triggering (REACT) and 4D contrast-enhanced MR-angiography. Magnetic Resonance Imaging. 2025. doi:10.1016/j.mri.2025.110423

BibTeX
@article{Gietzen2025,
  author = {Gietzen, Carsten and Tristram, Juliana and Janssen, Jan Paul and Hummels, Marielle and Bremm, Johannes and Kaya, Kenan and Gietzen, Thorsten and Pennig, Henry and Gertz, Roman and Persigehl, Thorsten and Stippel, Dirk and Weiss, Kilian and Pennig, Lenhard},
  title = {Imaging of the renal allograft vasculature without gadolinium contrast: Intraindividual comparison between relaxation-enhanced angiography without contrast and triggering (REACT) and 4D contrast-enhanced MR-angiography},
  journal = {Magnetic Resonance Imaging},
  year = {2025},
  doi = {10.1016/j.mri.2025.110423}
}
Kostenlos starten →