EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Non-contrast free-breathing 2D CINE compressed SENSE T1-TFE cardiovascular MRI at 3T in sedated young children for assessment of congenital heart disease

Inka Ristow iD, Caroline-Viktoria Hancken-Pauschinger, Shuo Zhang, Maria Stark iD, Michael G Kaul, Carsten Rickers, Jochen Herrmann iD, Gerhard Adam, Peter Bannas, Lennart Well, Julius Matthias Weinrich

PLOS ONE · 08.02.2024 · 19 (2) · e0297314

DOI: 10.1371/journal.pone.0297314 ↗

Kurz gefasst

Fachartikel in der Zeitschrift PLOS ONE, online erschienen am 08.02.2024. Verfasst von Inka Ristow und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany. Hauptthemen laut MEDLINE: Contrast Media, Heart Defects, Congenital. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 51 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Cardiac MRI is a crucial tool for assessing congenital heart disease (CHD). However, its application remains challenging in young children when performed at 3T. The aim of this retrospective single center study was to compare a non-contrast free-breathing 2D CINE T1-weighted TFE-sequence with compressed sensing (FB 2D CINE CS T1-TFE) with 3D imaging for diagnostic accuracy of CHD, image quality, and vessel diameter measurements in sedated young children. FB 2D CINE CS T1-TFE was compared with a 3D non-contrast whole-heart sequence (3D WH) and 3D contrast-enhanced MR angiography (3D CE-MRA) at 3T in 37 CHD patients (20♂, 1.5±1.4 years). Two radiologists independently assessed image quality, type of CHD, and diagnostic confidence. Diameters and measures of contrast and sharpness of the aorta and pulmonary vessels were determined. A non-parametric multi-factorial approach was used to estimate diagnostic accuracy for the diagnosis of CHD. Linear mixed models were calculated to compare contrast and vessel sharpness. Krippendorff’s alpha was determined to quantify vessel diameter agreement. FB 2D CINE CS T1-TFE was rated superior regarding image quality, diagnostic confidence, and diagnostic sensitivity for both intra- and extracardiac pathologies compared to 3D WH and 3D CE-MRA (all p

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Contrast MediaHeart Defects, CongenitalChildHumansChild, PreschoolRetrospective StudiesImaging, Three-DimensionalMagnetic Resonance ImagingMagnetic Resonance AngiographyReproducibility of Results

Substanzen

Contrast Media

Autor:innen und Institutionen

  • Department of Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany.
  • Department of Diagnostic and Interventional Radiology and Nuclear Medicine, Section of Pediatric Radiology, University Medical Center Hamburg-Eppendorf, Hamburg, Germany.
  • Philips GmbH Market DACH, Hamburg, Germany.
  • Institute of Medical Biometry and Epidemiology, University Medical Center Hamburg-Eppendorf, Hamburg, Germany.
  • University Heart Center, Adult Congenital Heart Disease Unit, University Medical Center Hamburg-Eppendorf, Hamburg, Germany.

ORCID-Profile: Inka Ristow, Maria Stark, Jochen Herrmann

Zitieren

APA

Ristow, I., Hancken-Pauschinger, C. V., Zhang, S., Stark, M., Kaul, M. G., Rickers, C., Herrmann, J., Adam, G., Bannas, P., Well, L., & Weinrich, J. M. (2024). Non-contrast free-breathing 2D CINE compressed SENSE T1-TFE cardiovascular MRI at 3T in sedated young children for assessment of congenital heart disease. PLOS ONE, 19(2), e0297314. https://doi.org/10.1371/journal.pone.0297314

Vancouver

Ristow I, Hancken-Pauschinger CV, Zhang S, Stark M, Kaul MG, Rickers C, et al. Non-contrast free-breathing 2D CINE compressed SENSE T1-TFE cardiovascular MRI at 3T in sedated young children for assessment of congenital heart disease. PLOS ONE. 2024;19(2):e0297314. doi:10.1371/journal.pone.0297314

BibTeX
@article{Ristow2024,
  author = {Ristow, Inka and Hancken-Pauschinger, Caroline-Viktoria and Zhang, Shuo and Stark, Maria and Kaul, Michael G and Rickers, Carsten and Herrmann, Jochen and Adam, Gerhard and Bannas, Peter and Well, Lennart and Weinrich, Julius Matthias},
  title = {Non-contrast free-breathing 2D CINE compressed SENSE T1-TFE cardiovascular MRI at 3T in sedated young children for assessment of congenital heart disease},
  journal = {PLOS ONE},
  year = {2024},
  volume = {19},
  number = {2},
  pages = {e0297314},
  doi = {10.1371/journal.pone.0297314}
}
Kostenlos starten →