Evaluating a novel accelerated free-breathing late gadolinium enhancement imaging sequence for assessment of myocardial injury
Magnetic Resonance Imaging · 2024
DOI: 10.1016/j.mri.2024.01.020 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance Imaging, 2024. Verfasst von Nitish Bhatt und 7 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Medicine, University of Toronto, Toronto, ON, Canada. Hauptthemen laut MEDLINE: Contrast Media, COVID-19. Die Arbeit nennt 33 Literaturangaben.
Abstract (Originalsprache)
INTRODUCTION: Cardiac magnetic resonance imaging (MRI), including late gadolinium enhancement (LGE), plays an important role in the diagnosis and prognostication of ischemic and non-ischemic myocardial injury. Conventional LGE sequences require patients to perform multiple breath-holds and require long acquisition times. In this study, we compare image quality and assessment of myocardial LGE using an accelerated free-breathing sequence to the conventional standard-of-care sequence. METHODS: In this prospective cohort study, a total of 41 patients post Coronavirus 2019 (COVID-19) infection were included. Studies were performed on a 1.5 Tesla scanner with LGE imaging acquired using a conventional inversion recovery rapid gradient echo (conventional LGE) sequence followed by the novel accelerated free-breathing (FB-LGE) sequence. Image quality was visually scored (ordinal scale from 1 to 5) and compared between conventional and free-breathing sequences using the Wilcoxon rank sum test. Presence of per-segment LGE was identified according to the American Heart Association 16-segment myocardial model and compared across both conventional LGE and FB-LGE sequences using a two-sided chi-square test. The perpatient LGE extent was also evaluated using both sequences and compared using the Wilcoxon rank sum test. Interobserver variability in detection of per-segment LGE and per-patient LGE extent was evaluated using Cohen's kappa statistic and interclass correlation (ICC), respectively. RESULTS: The mean acquisition time for the FB-LGE sequence was 17 s compared to 413 s for the conventional LGE sequence (P < 0.001). Assessment of image quality was similar between both sequences (P = 0.19). There were no statistically significant differences in LGE assessed using the FB-LGE versus conventional LGE on a per-segment (P = 0.42) and per-patient (P = 0.06) basis. Interobserver variability in LGE assessment for FB-LGE was good for per-segment (= 0.71) and per-patient extent (ICC = 0.92) analyses. CONCLUSIONS: The accelerated FB-LGE sequence performed comparably to the conventional standard-of-care LGE sequence in a cohort of patients post COVID-19 infection in a fraction of the time and without the need for breath-holding. Such a sequence could impact clinical practice by increasing cardiac MRI throughput and accessibility for frail or acutely ill patients unable to perform breath-holding.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Faculty of Medicine, University of Toronto, Toronto, ON, Canada.
- Schulich Heart Program, Sunnybrook Health Sciences Centre, Toronto, ON, Canada.
- Division of Cardiology, St. Michael's Hospital, Toronto, ON, Canada.
- Schulich Heart Program, Sunnybrook Health Sciences Centre, Toronto, ON, Canada; Physical Sciences Platform, Sunnybrook Research Institute, Toronto, ON, Canada; Department of Medical Biophysics, University of Toronto, To…
- Schulich Heart Program, Sunnybrook Health Sciences Centre, Toronto, ON, Canada. Electronic address: idan.roifman@sunnybrook.ca.
Zitieren
APA
Bhatt, N., Orbach, A., Biswas, L., Strauss, B. H., Connelly, K., Ghugre, N. R., Wright, G. A., & Roifman, I. (2024). Evaluating a novel accelerated free-breathing late gadolinium enhancement imaging sequence for assessment of myocardial injury. Magnetic Resonance Imaging. https://doi.org/10.1016/j.mri.2024.01.020
Vancouver
Bhatt N, Orbach A, Biswas L, Strauss BH, Connelly K, Ghugre NR, et al. Evaluating a novel accelerated free-breathing late gadolinium enhancement imaging sequence for assessment of myocardial injury. Magnetic Resonance Imaging. 2024. doi:10.1016/j.mri.2024.01.020
BibTeX
@article{Bhatt2024,
author = {Bhatt, Nitish and Orbach, Ady and Biswas, Labonny and Strauss, Bradley H and Connelly, Kim and Ghugre, Nilesh R and Wright, Graham A and Roifman, Idan},
title = {Evaluating a novel accelerated free-breathing late gadolinium enhancement imaging sequence for assessment of myocardial injury},
journal = {Magnetic Resonance Imaging},
year = {2024},
doi = {10.1016/j.mri.2024.01.020}
}
EUVIMED