EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY 4.0

Comparing regularized Kelvinlet functions and the finite element method for registration of medical images to sparse organ data

Morgan J Ringel, Jon S Heiselman, Winona L Richey, Ingrid M Meszoely, William R Jarnagin, Michael I Miga

Medical Image Analysis · 2024

DOI: 10.1016/j.media.2024.103221 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Medical Image Analysis, 2024. Verfasst von Morgan J Ringel und 5 weiteren Autor:innen. Beteiligte Einrichtung: Vanderbilt University, Department of Biomedical Engineering, Nashville, TN, USA; Vanderbilt Institute for Surgery and Engineering, Nashville, TN, USA…. Hauptthemen laut MEDLINE: Finite Element Analysis, Algorithms, Phantoms, Imaging, Liver. Die Arbeit wurde bisher 15-mal zitiert (Crossref) und nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NCI NIH HHS, NIBIB NIH HHS, NIH HHS.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Image-guided surgery collocates patient-specific data with the physical environment to facilitate surgical decision making. Unfortunately, these guidance systems commonly become compromised by intraoperative soft-tissue deformations. Nonrigid image-to-physical registration methods have been proposed to compensate for deformations, but clinical utility requires compatibility of these techniques with data sparsity and temporal constraints in the operating room. While finite element models can be effective in sparse data scenarios, computation time remains a limitation to widespread deployment. This paper proposes a registration algorithm that uses regularized Kelvinlets, which are analytical solutions to linear elasticity in an infinite domain, to overcome these barriers. This algorithm is demonstrated and compared to finite element-based registration on two datasets: a phantom liver deformation dataset and an in vivo breast deformation dataset. The regularized Kelvinlets algorithm resulted in a significant reduction in computation time compared to the finite element method. Accuracy as evaluated by target registration error was comparable between methods. Average target registration errors were 4.6 ± 1.0 and 3.2 ± 0.8 mm on the liver dataset and 5.4 ± 1.4 and 6.4 ± 1.5 mm on the breast dataset for the regularized Kelvinlets and finite element method, respectively. Limitations of regularized Kelvinlets include the lack of organ-specific geometry and the assumptions of linear elasticity and infinitesimal strain. Despite limitations, this work demonstrates the generalizability of regularized Kelvinlets registration on two soft-tissue elastic organs. This method may improve and accelerate registration for image-guided surgery, and it shows the potential of using regularized Kelvinlets on medical imaging data.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Finite Element AnalysisAlgorithmsPhantoms, ImagingLiverHumansFemaleSurgery, Computer-AssistedBreastReproducibility of ResultsImage Interpretation, Computer-AssistedSensitivity and Specificity

Stichwörter der Autor:innen

BiomechanicsImage-guidanceRegistrationSparse data

Autor:innen und Institutionen

  • Vanderbilt University, Department of Biomedical Engineering, Nashville, TN, USA; Vanderbilt Institute for Surgery and Engineering, Nashville, TN, USA. Electronic address: morgan.j.ringel@Vanderbilt.edu.
  • Vanderbilt University, Department of Biomedical Engineering, Nashville, TN, USA; Vanderbilt Institute for Surgery and Engineering, Nashville, TN, USA; Memorial Sloan-Kettering Cancer Center, Department of Surgery, New Y…
  • Vanderbilt University, Department of Biomedical Engineering, Nashville, TN, USA; Vanderbilt Institute for Surgery and Engineering, Nashville, TN, USA.
  • Vanderbilt University Medical Center, Division of Surgical Oncology, Nashville, TN, USA.
  • Memorial Sloan-Kettering Cancer Center, Department of Surgery, New York, NY, USA.

Förderung

  • NCI NIH HHS
  • NIBIB NIH HHS
  • NIH HHS

Zitieren

APA

Ringel, M. J., Heiselman, J. S., Richey, W. L., Meszoely, I. M., Jarnagin, W. R., & Miga, M. I. (2024). Comparing regularized Kelvinlet functions and the finite element method for registration of medical images to sparse organ data. Medical Image Analysis. https://doi.org/10.1016/j.media.2024.103221

Vancouver

Ringel MJ, Heiselman JS, Richey WL, Meszoely IM, Jarnagin WR, Miga MI. Comparing regularized Kelvinlet functions and the finite element method for registration of medical images to sparse organ data. Medical Image Analysis. 2024. doi:10.1016/j.media.2024.103221

BibTeX
@article{Ringel2024,
  author = {Ringel, Morgan J and Heiselman, Jon S and Richey, Winona L and Meszoely, Ingrid M and Jarnagin, William R and Miga, Michael I},
  title = {Comparing regularized Kelvinlet functions and the finite element method for registration of medical images to sparse organ data},
  journal = {Medical Image Analysis},
  year = {2024},
  doi = {10.1016/j.media.2024.103221}
}
Kostenlos starten →