FEM simulation of breast deformation with semi-fluid representation
International Journal of Computer Assisted Radiology and Surgery · 2024
DOI: 10.1007/s11548-024-03288-8 ↗Kurz gefasst
Fachartikel in der Zeitschrift International Journal of Computer Assisted Radiology and Surgery, 2024. Verfasst von Shota Takahashi und 5 weiteren Autor:innen. Beteiligte Einrichtung: Degree Programs in System and Information Engineering, University of Tsukuba, 1-1-1 Tennodai, Tsukuba City, Ibaraki, 305-8573, Japan. Hauptthemen laut MEDLINE: Breast Neoplasms, Finite Element Analysis, Surgery, Computer-Assisted, Computer Simulation. Die Arbeit nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Japan Society for the Promotion of Science, Japan Agency for Medical Research and Development.
Abstract (Originalsprache)
Purpose
In image-guided surgery for breast cancer, the representation of the breast deformation between planning and surgery plays a key role. The breast deforms significantly and behaves as a fluid with some constraints. Concretely, the deep fat layer in the breast deforms fluidly due to its incomplete fixation to the chest wall, while the anchoring structures by fascia avoid excessive deformation. In this study, we propose a method to simulate the semi-fluid deformation of the breast, considering the fluidic properties of the adipose tissue under the constraints of the anchoring structures.
Methods
The proposed method prioritizes anatomical features of the breast, enhancing tissue mobility near the chest wall and modeling the anchoring structure of the fascia along the inframammary fold. To simulate semi-fluid deformation, constraint force from anchoring structure is applied to prone-positioned breast model, using a finite element method.
Results
The results of the evaluation indicate a tumor center registration error of 11.87 ± 4.05 mm. Additionally, we verified how semi-fluid representation affects the registration error. The tumor’s Hausdorff distance decreased from 12.89 ± 6.24 mm to 11.50 ± 4.38 mm with considering semi-fluidity.
Conclusion
The results showed that the use of semi-fluid representation tends to reduce registration errors. Therefore, it was suggested that the proposed method could improve the accuracy of breast posture conversion.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Degree Programs in System and Information Engineering, University of Tsukuba, 1-1-1 Tennodai, Tsukuba City, Ibaraki, 305-8573, Japan.
- Department of General Surgery, Chiba University Graduate School of Medicine, 1-8-1 Inohana Chuo-ku, Chiba City, Chiba, 260-0856, Japan.
- Comprehensive Radiology Center, Chiba University Hospital, 1-8-1 Inohana Chuo-ku, Chiba City, Chiba, 266-8677, Japan.
- Center for Frontier Medical Engineering, Chiba University, 1-33 Yayoi Cho Inage Ku, Chiba City, Chiba, 263-8522, Japan.
- Institute of Systems and Information Engineering, University of Tsukuba, 1-1-1 Tennodai, Tsukuba City, Ibaraki, 305-8573, Japan.
- Institute of Systems and Information Engineering, University of Tsukuba, 1-1-1 Tennodai, Tsukuba City, Ibaraki, 305-8573, Japan. kuroda@iit.tsukuba.ac.jp.
Förderung
- Japan Society for the Promotion of Science
- Japan Agency for Medical Research and Development
Zitieren
APA
Takahashi, S., Fujimoto, H., Nasu, K., Nakaguchi, T., Ienaga, N., & Kuroda, Y. (2024). FEM simulation of breast deformation with semi-fluid representation. International Journal of Computer Assisted Radiology and Surgery. https://doi.org/10.1007/s11548-024-03288-8
Vancouver
Takahashi S, Fujimoto H, Nasu K, Nakaguchi T, Ienaga N, Kuroda Y. FEM simulation of breast deformation with semi-fluid representation. International Journal of Computer Assisted Radiology and Surgery. 2024. doi:10.1007/s11548-024-03288-8
BibTeX
@article{Takahashi2024,
author = {Takahashi, Shota and Fujimoto, Hiroshi and Nasu, Katsuhiro and Nakaguchi, Toshiya and Ienaga, Naoto and Kuroda, Yoshihiro},
title = {FEM simulation of breast deformation with semi-fluid representation},
journal = {International Journal of Computer Assisted Radiology and Surgery},
year = {2024},
doi = {10.1007/s11548-024-03288-8}
}
EUVIMED