Smartphone-based particle tracking velocimetry for the in vitro assessment of coronary flows
Medical Engineering & Physics · 2024
DOI: 10.1016/j.medengphy.2024.104144 ↗Kurz gefasst
Fachartikel in der Zeitschrift Medical Engineering & Physics, 2024. Verfasst von Elena Torta und 6 weiteren Autor:innen. Beteiligte Einrichtung: Polito(BIO)Med Lab, Department of Mechanical and Aerospace Engineering, Politecnico di Torino, Turin, Italy. Hauptthemen laut MEDLINE: Smartphone, Cardiovascular Physiological Phenomena. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 52 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Italian Ministry of Education, University and Research, MUR.
Abstract (Originalsprache)
The present study adopts a smartphone-based approach for the experimental characterization of coronary flows. Technically, Particle Tracking Velocimetry (PTV) measurements were performed using a smartphone camera and a low-power continuous wave laser in realistic healthy and stenosed phantoms of left anterior descending artery with inflow Reynolds numbers approximately ranging from 20 to 200. A Lagrangian-Eulerian mapping was performed to convert Lagrangian PTV velocity data to a Eulerian grid. Eulerian velocity and vorticity data obtained from smartphone-based PTV measurements were compared with Particle Image Velocimetry (PIV) measurements performed with a smartphone-based setup and with a conventional setup based on a high-power double-pulsed laser and a CMOS camera. Smartphone-based PTV and PIV velocity flow fields substantially agreed with conventional PIV measurements, with the former characterized by lower average percentage differences than the latter. Discrepancies emerged at high flow regimes, especially at the stenosis throat, due to particle image blur generated by smartphone camera shutter speed and image acquisition frequency. In conclusion, the present findings demonstrate the feasibility of PTV measurements using a smartphone camera and a low-power light source for the in vitro characterization of cardiovascular flows for research, industrial and educational purposes, with advantages in terms of costs, safety and usability.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Polito(BIO)Med Lab, Department of Mechanical and Aerospace Engineering, Politecnico di Torino, Turin, Italy.
- Institute of Fluid Mechanics and Heat Transfer, TU Wien, Vienna, Austria.
- Polito(BIO)Med Lab, Department of Mechanical and Aerospace Engineering, Politecnico di Torino, Turin, Italy. Electronic address: diego.gallo@polito.it.
Förderung
- Italian Ministry of Education, University and Research
- MUR
Zitieren
APA
Torta, E., Griffo, B., Caridi, G. C. A., De Nisco, G., Chiastra, C., Morbiducci, U., & Gallo, D. (2024). Smartphone-based particle tracking velocimetry for the in vitro assessment of coronary flows. Medical Engineering & Physics. https://doi.org/10.1016/j.medengphy.2024.104144
Vancouver
Torta E, Griffo B, Caridi GCA, De Nisco G, Chiastra C, Morbiducci U, et al. Smartphone-based particle tracking velocimetry for the in vitro assessment of coronary flows. Medical Engineering & Physics. 2024. doi:10.1016/j.medengphy.2024.104144
BibTeX
@article{Torta2024,
author = {Torta, Elena and Griffo, Bianca and Caridi, Giuseppe C A and De Nisco, Giuseppe and Chiastra, Claudio and Morbiducci, Umberto and Gallo, Diego},
title = {Smartphone-based particle tracking velocimetry for the in vitro assessment of coronary flows},
journal = {Medical Engineering & Physics},
year = {2024},
doi = {10.1016/j.medengphy.2024.104144}
}
EUVIMED