Quality assessment of automatically planned o-ring linac SBRT plans for pelvic lymph node and lung metastases, evaluating the optimal minimum target size

Katerine Viviana Díaz Hernández, Sergejs Unterkirhers, Uwe Schneider

Medical Dosimetry · 2025

DOI: 10.1016/j.meddos.2025.01.008 ↗

Kurz gefasst

Evaluationsstudie in der Zeitschrift Medical Dosimetry, 2025. Verfasst von Katerine Viviana Díaz Hernández und 2 weiteren Autor:innen. Beteiligte Einrichtung: Medical Physics, Radiotherapy Hirslanden, Witellikerstrasse 40, CH-8032, Zürich, Switzerland; Science Faculty, University of Zürich, Winterthurerstra…. Hauptthemen laut MEDLINE: Radiosurgery, Radiotherapy Planning, Computer-Assisted, Lung Neoplasms, Lymphatic Metastasis. Die Arbeit nennt 33 Literaturangaben. Gefördert von: Varian Medical Systems.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The purpose of this study is to assess the influence of Planning Target Volume (PTV) on the quality of automatic planned O-Ring Halcyon linac stereotactic body radiation therapy (SBRT) plans of pelvic lymph nodes (LN) and lung metastases and to evaluate an absolute PTV volume threshold as a plan quality prediction criterion. A total of 21 pelvic LN and 18 lung clinical treatment plans were replanned for Halcyon with unattended autoplanning. The prescription dose range was 26-40 Gy for LN and between 39-54 Gy for the lung in the mean 3 fractions. The mean/median PTV was 4.0/ 3.6 cm3 for LN and 4.9/ 4.3 cm3 for the lung. The criteria for the plan quality evaluation consisted of using dose metrics for conformity, spillage, and coverage and dose limits on healthy tissue assessment. A statistical study was performed based on systematic Mann-Whitney U test and cluster analysis to evaluate a PTV volume predictor threshold of plan quality. 95% (n = 20) LN and 100% (n = 18) lung plans met all tolerance criteria. For both cohorts of plans, a PTV threshold was determined, indicating a reduction of particular dose indices when below this threshold. Low risk of toxicity in healthy tissues was predicted. A PTV threshold of 4.0 cm3 was estimated as quality criteria in both cohorts of plans. The results of our study demonstrated the promising performance of Halcyon for pelvic and lung SBRT for small tumors, although plan-specific QA is required to verify machine performance during plan delivery.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

RadiosurgeryRadiotherapy Planning, Computer-AssistedLung NeoplasmsLymphatic MetastasisQuality Assurance, Health CarePelvisLungDose Fractionation, RadiationOrgans at RiskFeasibility StudiesHumans

Stichwörter der Autor:innen

Lung metastasesO-ring linacPelvic lymph node metastasisSBRTVMAT

Autor:innen und Institutionen

  • Medical Physics, Radiotherapy Hirslanden, Witellikerstrasse 40, CH-8032, Zürich, Switzerland; Science Faculty, University of Zürich, Winterthurerstrasse 190, CH-8057, Zürich, Switzerland. Electronic address: katerineviv…
  • Medical Physics, Radiotherapy Hirslanden, Witellikerstrasse 40, CH-8032, Zürich, Switzerland.
  • Medical Physics, Radiotherapy Hirslanden, Witellikerstrasse 40, CH-8032, Zürich, Switzerland; Science Faculty, University of Zürich, Winterthurerstrasse 190, CH-8057, Zürich, Switzerland.

Förderung

  • Varian Medical Systems

Zitieren

APA

Díaz Hernández, K. V., Unterkirhers, S., & Schneider, U. (2025). Quality assessment of automatically planned o-ring linac SBRT plans for pelvic lymph node and lung metastases, evaluating the optimal minimum target size. Medical Dosimetry. https://doi.org/10.1016/j.meddos.2025.01.008

Vancouver

Díaz Hernández KV, Unterkirhers S, Schneider U. Quality assessment of automatically planned o-ring linac SBRT plans for pelvic lymph node and lung metastases, evaluating the optimal minimum target size. Medical Dosimetry. 2025. doi:10.1016/j.meddos.2025.01.008

BibTeX
@article{DazHernndez2025,
  author = {Díaz Hernández, Katerine Viviana and Unterkirhers, Sergejs and Schneider, Uwe},
  title = {Quality assessment of automatically planned o-ring linac SBRT plans for pelvic lymph node and lung metastases, evaluating the optimal minimum target size},
  journal = {Medical Dosimetry},
  year = {2025},
  doi = {10.1016/j.meddos.2025.01.008}
}
Kostenlos starten →