An anatomical artificial bone implant can improve three-dimensional correction accuracy in open-wedge high tibial osteotomy
The Knee · 2025
DOI: 10.1016/j.knee.2024.10.017 ↗Kurz gefasst
Fachartikel in der Zeitschrift The Knee, 2025. Verfasst von Yugo Morita und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedic Surgery, Graduate School of Medicine, Kyoto University, Kyoto, Japan; Department of Orthopaedic Surgery, Hayashi Hospital, …. Hauptthemen laut MEDLINE: Osteotomy, Tibia, Imaging, Three-Dimensional, Tomography, X-Ray Computed. Die Arbeit nennt 51 Literaturangaben. Gefördert von: AMED.
Abstract (Originalsprache)
BACKGROUND: An anatomical artificial bone implant inserted into the osteotomy gap might be useful for accurate alignment correction during open-wedge high tibial osteotomy (OWHTO). The aims of this study were to evaluate morphological variation in the osteotomy surface, identify an anatomical implant's shape, and verify its usefulness for accurate three-dimensional (3D) correction. METHODS: Virtual OWHTO was performed with preoperative 3D computed tomography data from 100 knees. The tibial contour in the osteotomy plane was analyzed using principal component analysis to determine implant shape. An anatomical artificial bone implant with a 10° correction angle was made with a synthetic bone substitute. Coronal correction accuracy and changes in posterior tibial slope (PTS) and rotation were evaluated on eight cadaver knees that received the anatomical artificial bone implant and clinically on 85 in vivo knees that received conventional wedge-shaped spacers. RESULTS: The single-shape anatomical artificial bone implant was designed to occupy a posteromedial 30 × 25 mm region and had high contour congruency (mean mismatch, 0.73 mm; mean contact area coverage, 97.5%). Gap opening angle with the anatomical artificial bone implant was precise, avoiding excessive PTS change (mean, 0.6°) and rotational change (mean, 0.5°). In contrast, both PTS and rotational change with conventional spacers increased by a mean of 2.9°. CONCLUSIONS: An anatomical artificial bone implant derived from the mean shape of 100 knees had high and consistent contour congruency. The anatomical artificial bone implant inserted with 3D surgical guidance provided accurate gap opening, reducing PTS change to less than 1° during OWHTO.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Orthopaedic Surgery, Graduate School of Medicine, Kyoto University, Kyoto, Japan; Department of Orthopaedic Surgery, Hayashi Hospital, Fukui, Japan.
- Department of Orthopaedic Surgery, Graduate School of Medicine, Kyoto University, Kyoto, Japan. Electronic address: kuriyama@kuhp.kyoto-u.ac.jp.
- Department of Orthopaedic Surgery, Graduate School of Medicine, Kyoto University, Kyoto, Japan.
- Department of Orthopaedic Surgery, Kurashiki Central Hospital, Okayama, Japan.
Förderung
- AMED
Zitieren
APA
Morita, Y., Kuriyama, S., Yamawaki, Y., Nakamura, S., Nishitani, K., Ito, H., & Matsuda, S. (2025). An anatomical artificial bone implant can improve three-dimensional correction accuracy in open-wedge high tibial osteotomy. The Knee. https://doi.org/10.1016/j.knee.2024.10.017
Vancouver
Morita Y, Kuriyama S, Yamawaki Y, Nakamura S, Nishitani K, Ito H, et al. An anatomical artificial bone implant can improve three-dimensional correction accuracy in open-wedge high tibial osteotomy. The Knee. 2025. doi:10.1016/j.knee.2024.10.017
BibTeX
@article{Morita2025,
author = {Morita, Yugo and Kuriyama, Shinichi and Yamawaki, Yusuke and Nakamura, Shinichiro and Nishitani, Kohei and Ito, Hiromu and Matsuda, Shuichi},
title = {An anatomical artificial bone implant can improve three-dimensional correction accuracy in open-wedge high tibial osteotomy},
journal = {The Knee},
year = {2025},
doi = {10.1016/j.knee.2024.10.017}
}
EUVIMED