EUVIMEDEUVIMED entdecken
Crossref

Accuracy of medial opening wedge high tibial osteotomy using patient-specific instrumentation: a randomised cadaveric study

Stephan Meschian-Coretti, Juan Miguel Gómez-Palomo, Juan José García-Vera, Pablo Salinas-Sánchez, Marc Stefan Dawid-Milner, Elvira Montañez-Heredia

European Journal of Orthopaedic Surgery & Traumatology · 2025

DOI: 10.1007/s00590-025-04585-x ↗

Kurz gefasst

Fachartikel in der Zeitschrift European Journal of Orthopaedic Surgery & Traumatology, 2025. Verfasst von Stephan Meschian-Coretti und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedic Surgery, HM Santa Elena Hospital, Málaga, Spain. Hauptthemen laut MEDLINE: Osteotomy, Surgery, Computer-Assisted, Tibia. Die Arbeit nennt 14 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: To determine whether patient-specific instrumentation (PSI) reduces the angular deviation between planned and executed osteotomy lines, compared with the conventional freehand technique, using direct three-dimensional analysis of pre- and postoperative CT models. METHODS: A randomised study was conducted on 18 fresh-frozen human tibiae. Specimens were assigned to either PSI-assisted or conventional osteotomy groups. Osteotomies were planned on 3D CT models and executed by experienced surgeons. Pre- and postoperative CT scans were used to assess osteotomy angles and the distance from the cut to the joint line. The primary outcome was the difference between planned and executed osteotomy angles in the anteroposterior (AP) and lateral planes. Secondary outcomes included deviation in cut location and variability in results. RESULTS: Baseline characteristics were comparable between groups. PSI significantly reduced angular deviation in both the AP (2.8° ± 2.0 vs. 6.1° ± 5.6; p = 0.003) and lateral planes (2.1° ± 1.5 vs. 5.8° ± 6.0; p = 0.001). No significant difference was observed in the distance to the joint line (p = 0.136). The PSI group showed greater consistency and fewer outliers compared to the conventional group. CONCLUSION: PSI significantly enhances the accuracy and reproducibility of osteotomy execution in medial opening wedge HTO compared with the freehand technique. These findings are limited to a cadaveric model and reflect technical accuracy at the cut level; any clinical impact requires confirmation in prospective in vivo studies. CLINICAL RELEVANCE: In this experimental cadaveric model, PSI demonstrated improved cut-level accuracy; potential clinical benefits remain to be established in patient cohorts. LEVEL OF EVIDENCE: Level II - Randomised cadaveric study.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

OsteotomySurgery, Computer-AssistedTibiaAgedFemaleHumansMaleMiddle AgedCadaverImaging, Three-DimensionalTomography, X-Ray ComputedRandom Allocation

Stichwörter der Autor:innen

3D planningCadaveric studyHigh tibial osteotomyMedial opening wedgeOsteotomy accuracyPatient-specific instrumentationSurgical precision

Autor:innen und Institutionen

  • Department of Orthopaedic Surgery, HM Santa Elena Hospital, Málaga, Spain.
  • Biomedical Research Institute of Málaga (IBIMA), Málaga, Spain.
  • Biomedical Research Institute of Málaga (IBIMA), Málaga, Spain. jmgomezpalomo@gmail.com.
  • Department of Orthopedic Surgery and Traumatology, Virgen de la Victoria University Hospital, Málaga, Spain. jmgomezpalomo@gmail.com.
  • Department of Orthopedic Surgery and Traumatology, Virgen de la Victoria University Hospital, Málaga, Spain.
  • Faculty of Medicine, University of Malaga, Málaga, Spain.

Zitieren

APA

Meschian-Coretti, S., Gómez-Palomo, J. M., García-Vera, J. J., Salinas-Sánchez, P., Dawid-Milner, M. S., & Montañez-Heredia, E. (2025). Accuracy of medial opening wedge high tibial osteotomy using patient-specific instrumentation: a randomised cadaveric study. European Journal of Orthopaedic Surgery & Traumatology. https://doi.org/10.1007/s00590-025-04585-x

Vancouver

Meschian-Coretti S, Gómez-Palomo JM, García-Vera JJ, Salinas-Sánchez P, Dawid-Milner MS, Montañez-Heredia E. Accuracy of medial opening wedge high tibial osteotomy using patient-specific instrumentation: a randomised cadaveric study. European Journal of Orthopaedic Surgery & Traumatology. 2025. doi:10.1007/s00590-025-04585-x

BibTeX
@article{MeschianCoretti2025,
  author = {Meschian-Coretti, Stephan and Gómez-Palomo, Juan Miguel and García-Vera, Juan José and Salinas-Sánchez, Pablo and Dawid-Milner, Marc Stefan and Montañez-Heredia, Elvira},
  title = {Accuracy of medial opening wedge high tibial osteotomy using patient-specific instrumentation: a randomised cadaveric study},
  journal = {European Journal of Orthopaedic Surgery & Traumatology},
  year = {2025},
  doi = {10.1007/s00590-025-04585-x}
}
Kostenlos starten →