Fallbericht in der Zeitschrift The Knee, 2024. Verfasst von Kai Nie und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Lower Limb Arthroplasty, Liverpool University Hospitals NHS Foundation Trust, Liverpool, United Kingdom. Electronic address: kai.nie@nh…. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Knee, Knee Prosthesis, Polyethylene, Prosthesis Failure. Die Arbeit nennt 16 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

INTRODUCTION: This short paper reports a potential emerging mode of failure in three patients with a bicruciate stabilised (BCS) total knee arthroplasty. METHODS: Three patients presented to our institution with late instability ten years after undergoing total knee arthroplasty (Journey BCS) and were asymptomatic up to this point. Retrieval analysis was performed by an external body commissioned by the NHS and all three cases were reported to the UK Medicines and Healthcare Products Regulatory Agency (MHRA). RESULTS: Two patients were revised through simple exchange with a polyethylene tibial insert. One patient underwent a full revision of femoral and tibial components. Intra-operative findings revealed that the polyethylene post had fractured in an identical manner in all three cases. Retrieval analysis demonstrated posterior impingement and wear of the polyethylene post resulting in fatigue failure. CONCLUSIONS: This short paper highlights a potential emerging mode of failure with Journey BCS that requires wider dissemination to raise awareness among surgeons and calls for long-term follow up of those patients who received this specific implant. Early revision with polyethylene exchange is a successful treatment in patients when femoral and tibial components are well-positioned and well-fixed.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, KneeKnee ProsthesisPolyethyleneProsthesis FailureReoperationProsthesis DesignHumansFemaleAgedMaleMiddle AgedTibiaJoint Instability

Stichwörter der Autor:innen

Bicruciate stabilisedPolyethyleneRetrieval analysisTibial post fractureTotal knee arthroplasty

Substanzen

Polyethylene

Autor:innen und Institutionen

  • Department of Lower Limb Arthroplasty, Liverpool University Hospitals NHS Foundation Trust, Liverpool, United Kingdom. Electronic address: kai.nie@nhs.net.
  • Department of Lower Limb Arthroplasty, Liverpool University Hospitals NHS Foundation Trust, Liverpool, United Kingdom.
  • Department of Lower Limb Arthroplasty, Liverpool University Hospitals NHS Foundation Trust, Liverpool, United Kingdom; Faculty of Health and Life Sciences, The University of Liverpool, United Kingdom.

Zitieren

APA

Nie, K., Guest, D., Davidson, J. S., & Santini, A. J. A. (2024). Tibial polyethylene post fractures at ten-years in a bicruciate stabilised (BCS) total knee arthroplasty design. The Knee. https://doi.org/10.1016/j.knee.2023.12.009

Vancouver

Nie K, Guest D, Davidson JS, Santini AJA. Tibial polyethylene post fractures at ten-years in a bicruciate stabilised (BCS) total knee arthroplasty design. The Knee. 2024. doi:10.1016/j.knee.2023.12.009

BibTeX
@article{Nie2024,
  author = {Nie, Kai and Guest, Dominie and Davidson, John S and Santini, Alasdair J A},
  title = {Tibial polyethylene post fractures at ten-years in a bicruciate stabilised (BCS) total knee arthroplasty design},
  journal = {The Knee},
  year = {2024},
  doi = {10.1016/j.knee.2023.12.009}
}
Kostenlos starten →