EUVIMEDEUVIMED entdecken
Multizentrische StudieOpen Access · CC BY 4.0

Oxidation and Damage Mechanisms of Second-Generation Highly Cross-Linked Polyethylene Tibial Inserts

Tabitha Derr, Daniel W MacDonald, Arthur L Malkani, Michael A Mont, Nicolas S Piuzzi, Steven M Kurtz

The Journal of Arthroplasty · 2024

DOI: 10.1016/j.arth.2024.06.032 ↗

Kurz gefasst

Multizentrische Studie in der Zeitschrift The Journal of Arthroplasty, 2024. Verfasst von Tabitha Derr und 5 weiteren Autor:innen. Beteiligte Einrichtung: Implant Research Core, Drexel University, Philadelphia, Pennsylvania. Hauptthemen laut MEDLINE: Knee Prosthesis, Arthroplasty, Replacement, Knee, Prosthesis Failure, Reoperation. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: After clinical introduction in 2005, sequentially annealed, highly cross-linked polyethylene (SA HXLPE) was studied for retrievals with short implantation times; however, long-term follow-ups are lacking. The objective of this study was to examine and compare the revision reasons, damage mechanisms, and oxidation indices of SA HXLPE and conventional gamma inert-sterilized (Gamma Inert) ultra-high-molecular-weight polyethylene tibial inserts implanted for >5 years. METHODS: There were 74 total knee arthroplasty tibial inserts (46 SA HXLPEs, 28 Gamma Inerts) implanted for >5 years (mean 7 ± 2 years) retrieved as part of a multicenter retrieval program. Cruciate-retaining implants comprised 44% of the SA HXLPEs and 14% of the Gamma Inerts. Patient factors and revision reasons were collected from revision operating notes. A semiquantitative scoring method was used to assess surface damage mechanisms. Oxidation was measured using Fourier transform infrared microscopy according to American Society for Testing and Materials 2102. Differences between cohorts were assessed with Mann-Whitney U-tests. RESULTS: Loosening (Gamma Inert: 17 of 28, SA HXLPE: 15 of 46) and instability (Gamma Inert: 6 of 28, SA HXLPE: 15 of 46) were the most common revision reasons for both cohorts. The most prevalent surface damage mechanisms were burnishing, pitting, and scratching, with burnishing of the condyles being higher in Gamma Inert components (P = .022). Mean oxidation was higher in the SA HXLPE inserts at the articulating surface (P = .002) and anterior-posterior faces (P = .023). No difference was observed at the backside surface (P = .060). CONCLUSIONS: Revision reasons and surface damage mechanisms were comparable in the Gamma Inert and SA cohorts. Further studies are needed to continue to assess the in vivo damage and clinical relevance, if any, of oxidation in SA HXLPE over longer implantation times, particularly for implants implanted for more than 10 years.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Knee ProsthesisArthroplasty, Replacement, KneeProsthesis FailureReoperationOxidation-ReductionHumansAgedMaleFemaleMiddle AgedPolyethyleneTibiaProsthesis DesignAged, 80 and overPolyethylenes

Stichwörter der Autor:innen

polyethyleneretrieval studiesrevision reasonssurface damagetotal knee arthroplasty

Substanzen

Polyethyleneultra-high molecular weight polyethylenePolyethylenes

Autor:innen und Institutionen

  • Implant Research Core, Drexel University, Philadelphia, Pennsylvania.
  • Department of Orthopaedic Surgery, University of Louisville, Louisville, Kentucky.
  • Department of Orthopaedic Surgery, Sinai Hospital of Baltimore, Rubin Institute for Advanced Orthopedics, Baltimore, Maryland.
  • Department of Orthopaedic Surgery, Cleveland Clinic, Cleveland, Ohio.

Zitieren

APA

Derr, T., MacDonald, D. W., Malkani, A. L., Mont, M. A., Piuzzi, N. S., & Kurtz, S. M. (2024). Oxidation and Damage Mechanisms of Second-Generation Highly Cross-Linked Polyethylene Tibial Inserts. The Journal of Arthroplasty. https://doi.org/10.1016/j.arth.2024.06.032

Vancouver

Derr T, MacDonald DW, Malkani AL, Mont MA, Piuzzi NS, Kurtz SM. Oxidation and Damage Mechanisms of Second-Generation Highly Cross-Linked Polyethylene Tibial Inserts. The Journal of Arthroplasty. 2024. doi:10.1016/j.arth.2024.06.032

BibTeX
@article{Derr2024,
  author = {Derr, Tabitha and MacDonald, Daniel W and Malkani, Arthur L and Mont, Michael A and Piuzzi, Nicolas S and Kurtz, Steven M},
  title = {Oxidation and Damage Mechanisms of Second-Generation Highly Cross-Linked Polyethylene Tibial Inserts},
  journal = {The Journal of Arthroplasty},
  year = {2024},
  doi = {10.1016/j.arth.2024.06.032}
}
Kostenlos starten →