EUVIMEDEUVIMED entdecken
Crossref

Aseptic survival of the 1.5‐stage exchange arthroplasty for periprosthetic joint infection was acceptable when using an autoclaved femoral component and a new polyethylene insert

Sang Jun Song, Sung Hyun Hwang, Hyun Jae Baek, Cheol Hee Park

Knee Surgery, Sports Traumatology, Arthroscopy · 2023

DOI: 10.1007/s00167-023-07552-3 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Knee Surgery, Sports Traumatology, Arthroscopy, 2023. Verfasst von Sang Jun Song und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedic Surgery, Kyung Hee University College of Medicine, Kyung Hee University Medical Center, 26 Kyunghee-daero, Dongdaemun-gu, S…. Hauptthemen laut MEDLINE: Prosthesis-Related Infections, Arthroplasty, Replacement, Knee, Knee Prosthesis, Prosthesis Failure. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 34 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To investigate the aseptic survival of 1.5‐stage exchange arthroplasty for periprosthetic joint infection (PJI) after total knee arthroplasty (TKA).

Methods

Eighty‐eight cases of 1.5‐stage exchange arthroplasty for PJI without reinfection were retrospectively analysed. The autoclaved femoral component and new polyethylene insert (PE) were implanted using antibiotic mixed cement. The explanted tibial component was not reinserted. The Western Ontario and McMaster Universities Osteoarthritis Index and range of motion were clinically evaluated preoperatively and at the last follow‐up (the last time for the implant in situ). Radiographically, hip–knee–ankle angle (HKA) and component positions were measured preoperatively, postoperatively (1 month after the 1.5‐stage exchange arthroplasty), and at the last follow‐up. The survival rate was analysed using the Kaplan–Meier method, in which failure was defined as reoperation due to aseptic failure. Mean period to failure and failure site were analysed. Factors affecting survival were investigated in terms of demographics and inappropriateness of the postoperative HKA (HKA > 0 ± 3°) and component positions ( α angle > 95 ± 3°, β angle > 90 ± 3°, γ angle > 3 ± 3°, and δ angle > 87 ± 3°).

Results

The spacer in‐situ time was 3.7 years (0.2–6.4). The clinical results improved hip–knee–ankle significantly at the last follow‐up. Radiographically, the average HKA was valgus 0.1° postoperatively. The average α , β , γ , and δ angles of the postoperative component positions were 95.9°, 90.4°, 3.8°, and 86.7°, respectively. The 1‐, 2‐, and 5‐year postoperative survival rates were 90.9%, 86.4%, and 80.6%, respectively. The mean period to failure was 2.0 years (0.2–5.3). There were 18 cases of aseptic loosening (20.8%), occurring on both the femur and tibial sides in 1 knee, and only on the tibial side in 17 knees. Inappropriate coronal position of the PE ( β angle > 90 ± 3°) was a significant factor affecting survival (odds ratio = 5.491; p = 0.011).

Conclusion

The aseptic survival of the 1.5‐stage exchange arthroplasty was acceptable when using an autoclaved femoral component and new PE. The appropriate coronal position of the PE helps ensure favourable survival of 1.5‐stage exchange arthroplasty. Level of evidence IV

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Prosthesis-Related InfectionsArthroplasty, Replacement, KneeKnee ProsthesisProsthesis FailureHumansMaleFemaleAgedRetrospective StudiesReoperationMiddle AgedPolyethyleneAged, 80 and overProsthesis Design

Stichwörter der Autor:innen

1.5-Stage exchange arthroplastyArthroplastyAseptic failureImplant survivalInfectionKneeSurgical procedures

Substanzen

Polyethylene

Autor:innen und Institutionen

  • Department of Orthopaedic Surgery, Kyung Hee University College of Medicine, Kyung Hee University Medical Center, 26 Kyunghee-daero, Dongdaemun-gu, Seoul, 02447, Korea.
  • Department of Orthopaedic Surgery, Kyung Hee University College of Medicine, Kyung Hee University Medical Center, 26 Kyunghee-daero, Dongdaemun-gu, Seoul, 02447, Korea. chpark0224@gmail.com.

Zitieren

APA

Song, S. J., Hwang, S. H., Baek, H. J., & Park, C. H. (2023). Aseptic survival of the 1.5‐stage exchange arthroplasty for periprosthetic joint infection was acceptable when using an autoclaved femoral component and a new polyethylene insert. Knee Surgery, Sports Traumatology, Arthroscopy. https://doi.org/10.1007/s00167-023-07552-3

Vancouver

Song SJ, Hwang SH, Baek HJ, Park CH. Aseptic survival of the 1.5‐stage exchange arthroplasty for periprosthetic joint infection was acceptable when using an autoclaved femoral component and a new polyethylene insert. Knee Surgery, Sports Traumatology, Arthroscopy. 2023. doi:10.1007/s00167-023-07552-3

BibTeX
@article{Song2023,
  author = {Song, Sang Jun and Hwang, Sung Hyun and Baek, Hyun Jae and Park, Cheol Hee},
  title = {Aseptic survival of the 1.5‐stage exchange arthroplasty for periprosthetic joint infection was acceptable when using an autoclaved femoral component and a new polyethylene insert},
  journal = {Knee Surgery, Sports Traumatology, Arthroscopy},
  year = {2023},
  doi = {10.1007/s00167-023-07552-3}
}
Kostenlos starten →