A biomechanical study to optimize superior capsular reconstruction operative technique
JSES International · 2024-05 · 8 (3) · 451-458
DOI: 10.1016/j.jseint.2023.06.005 ↗Kurz gefasst
Fachartikel in der Zeitschrift JSES International, 2024-05. Verfasst von Suhas P Dasari und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedics and Sports Medicine, University of Washington, Seattle, WA, USA. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Background
The goals of this study were to optimize superior capsular reconstruction by assessing the relative fixation strength of 4 suture anchors; evaluating 3 glenoid neck locations for fixation strength and bone mineral density (BMD); determining if there is a correlation between BMD and fixation strength; and determining which portal sites have optimal access to the posterosuperior and anterosuperior glenoid neck for anchor placement.
Methods
Twenty cadaveric specimens were randomized into 4 groups: all-suture anchor (FiberTak), conventional 3.0-mm knotless suture anchor (SutureTak), 3.9-mm knotless PEEK (polyetheretherketone) Corkscrew anchor, and 4.5-mm Bio-Corkscrew anchor. Each specimen was prepared with 3 anchors into the glenoid: an anterosuperior anchor, superior anchor, and posterosuperior anchor. All anchors were inserted into the superior glenoid neck 5 mm from the glenoid rim. A materials testing system performed cyclic testing (250 cycles) followed by load-to-failure testing at 12.5 mm/s. Cyclic elongation, first cycle excursion, maximum load, and stiffness were recorded. Using custom software, BMD was calculated at each anchor location. This software was also used to assess access to the posterosuperior and anterosuperior glenoid neck from standard arthroscopic portal positions.
Results
There was no significant difference in cyclic elongation (P = .546), first cycle excursion (P = .476), maximum load (P = .817), or stiffness (P = .309) among glenoid anchor positions. Cyclic elongation was significantly longer in the PEEK Corkscrew group relative to the other implants (P ≤ .002). First cycle excursion was significantly greater in the FiberTak group relative to all other implants (P ≤ .008). For load-to-failure testing, the Bio-Corkscrew group achieved the highest maximum load (P ≤ .001). No other differences in cyclic or failure testing were observed between the groups. No differences in stiffness testing were observed (P = .133). The superior glenoid rim had the greatest BMD (P = .003), but there was no correlation between BMD and cyclic/load outcomes. The posterior portal (80% of specimens) and the anterior portal (60% of specimens) demonstrated the best access to the posterosuperior and anterosuperior glenoid neck, respectively.
Conclusion
The 4.5-mm Bio-Corkscrew anchor provided the most robust fixation to the glenoid during superior capsular reconstruction as it demonstrated the strongest maximum load, had minimal elongation, had minimal first cycle excursion, and did not fail during cyclic testing. The superior glenoid neck had the highest BMD; however, there was no correlation between BMD or glenoid anchor location and biomechanical outcomes. The posterior portal and anterior portal provided optimal access to the posterosuperior glenoid neck and anterosuperior glenoid neck, respectively.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Orthopaedics and Sports Medicine, University of Washington, Seattle, WA, USA.
- Sidney Kimmel Medical College, Philadelphia, PA, USA.
- Oregon Shoulder Institute, Medford, OR, USA.
- Division of Sports Medicine, Midwest Orthopaedics at Rush, Department of Orthopaedic Surgery, Rush University Medical Center, Chicago, IL USA.
- Atrium Health Wake Forest Baptist, Wake Forest University School of Medicine, Winston-Salem, NC, USA.
Zitieren
APA
Dasari, S. P., Vadhera, A. S., Menendez, M. E., Khan, Z. A., Inoue, N., Shewman, E., Waterman, B. R., Garrigues, G. E., Cole, B. J., & Verma, N. N. (2024). A biomechanical study to optimize superior capsular reconstruction operative technique. JSES International, 8(3), 451-458. https://doi.org/10.1016/j.jseint.2023.06.005
Vancouver
Dasari SP, Vadhera AS, Menendez ME, Khan ZA, Inoue N, Shewman E, et al. A biomechanical study to optimize superior capsular reconstruction operative technique. JSES International. 2024;8(3):451-458. doi:10.1016/j.jseint.2023.06.005
BibTeX
@article{Dasari2024,
author = {Dasari, Suhas P and Vadhera, Amar S and Menendez, Mariano E and Khan, Zeeshan A and Inoue, Nozomu and Shewman, Elizabeth and Waterman, Brian R and Garrigues, Grant E and Cole, Brian J and Verma, Nikhil N},
title = {A biomechanical study to optimize superior capsular reconstruction operative technique},
journal = {JSES International},
year = {2024},
volume = {8},
number = {3},
pages = {451--458},
doi = {10.1016/j.jseint.2023.06.005}
}
EUVIMED