EUVIMEDEUVIMED entdecken
Crossref

Superior capsular reconstruction using the long head of biceps tendon: a biomechanical assessment of tenodesis location and angle of fixation

Daniel Paccot, Cole T Fleet, James A Johnson, George S Athwal

Journal of Shoulder and Elbow Surgery · 2025-03 · 34 (3) · 688-698

DOI: 10.1016/j.jse.2024.07.007 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Shoulder and Elbow Surgery, 2025-03. Verfasst von Daniel Paccot und 3 weiteren Autor:innen. Beteiligte Einrichtung: Roth | McFarlane Hand and Upper Limb Centre, St Joseph's Health Care, London, ON, Canada. Hauptthemen laut MEDLINE: Tenodesis, Shoulder Joint, Tendons, Rotator Cuff. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 36 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Massive irreparable rotator cuff tears (MIRCTs) treated with superior capsular reconstruction (SCR) using the long head of the biceps tendon have shown satisfactory early results. Different techniques and positions for biceps tenodesis have been described. This study aimed to evaluate the effect of tenodesis location and glenohumeral fixation angle for graft tensioning on the biomechanics of an SCR using a single-strand biceps technique. METHODS: Eight cadaveric shoulders were mounted onto a custom biomechanical simulator that used static tone loads to the deltoid and rotator cuff muscles. All cadavers were first tested in the intact condition, and then in the simulated MIRCT condition by sectioning the tendinous insertions of the supraspinatus and upper border of the infraspinatus. SCR using the long head of the biceps tendon was then evaluated. Three biceps tenodesis locations relative to the greater tuberosity (anterior, middle, and posterior) and 2 glenohumeral fixation angles (0° and 30°) for graft tensioning were tested. An optical tracking system was used to quantify superior-inferior and anterior-posterior humeral head translation relative to the glenoid, whereas the functional abduction force was quantified using a load sensor. All tests were conducted at 0°, 30°, and 60° of glenohumeral abduction in a randomized fashion. RESULTS: When assessing isolated superior humeral head migration, all biceps tenodesis locations were effective at decreasing superior migration, with no tenodesis location significantly better than the other (P = .213). However, biceps grafts tensioned at 30° of glenohumeral abduction were significantly better at reducing proximal humeral migration as compared to graft tensioning at 0° abduction (P = .008). Posterior humeral head translation observed in the MIRCT condition was significantly reduced when tensioning the biceps tendon at 30° of glenohumeral abduction compared with 0° for all tenodesis locations (P ≤ .043). The tenodesis location also significantly influenced posterior humeral head translation (P = .001), with the middle and posterior positions restoring near normal humeral head position when fixed at 30° glenohumeral abduction. All SCR techniques using the biceps tendon improved the functional abduction force relative to the MIRCT condition, although no statistically significant differences were observed relative to the intact condition (P ≥ .448). DISCUSSION: SCR using the long head of the biceps tendon is biomechanically effective in reducing posterosuperior translation of the humeral head in the setting of an MIRCT. Graft tensioning and fixation at 30° of glenohumeral abduction combined with either a middle or posterior tenodesis location on the greater tuberosity most effectively restores near normal time-zero humeral head kinematics.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

TenodesisShoulder JointTendonsRotator CuffJoint CapsuleHumansBiomechanical PhenomenaCadaverMaleAgedFemaleMiddle AgedRotator Cuff InjuriesAged, 80 and over

Stichwörter der Autor:innen

Superior capsule reconstructioncuff tear arthropathyhumeral head migrationlong head bicepsmassive rotator cuff tearsrotator cuff tearshoulder

Autor:innen und Institutionen

  • Roth | McFarlane Hand and Upper Limb Centre, St Joseph's Health Care, London, ON, Canada.
  • Roth | McFarlane Hand and Upper Limb Centre, St Joseph's Health Care, London, ON, Canada; Department of Mechanical and Materials Engineering, Western University, London, ON, Canada.
  • Roth | McFarlane Hand and Upper Limb Centre, St Joseph's Health Care, London, ON, Canada; Department of Surgery, Western University, London, ON, Canada. Electronic address: gsathwal@hotmail.com.

Zitieren

APA

Paccot, D., Fleet, C. T., Johnson, J. A., & Athwal, G. S. (2025). Superior capsular reconstruction using the long head of biceps tendon: a biomechanical assessment of tenodesis location and angle of fixation. Journal of Shoulder and Elbow Surgery, 34(3), 688-698. https://doi.org/10.1016/j.jse.2024.07.007

Vancouver

Paccot D, Fleet CT, Johnson JA, Athwal GS. Superior capsular reconstruction using the long head of biceps tendon: a biomechanical assessment of tenodesis location and angle of fixation. Journal of Shoulder and Elbow Surgery. 2025;34(3):688-698. doi:10.1016/j.jse.2024.07.007

BibTeX
@article{Paccot2025,
  author = {Paccot, Daniel and Fleet, Cole T and Johnson, James A and Athwal, George S},
  title = {Superior capsular reconstruction using the long head of biceps tendon: a biomechanical assessment of tenodesis location and angle of fixation},
  journal = {Journal of Shoulder and Elbow Surgery},
  year = {2025},
  volume = {34},
  number = {3},
  pages = {688--698},
  doi = {10.1016/j.jse.2024.07.007}
}
Kostenlos starten →