Biomechanical and clinical evaluations of superior capsular reconstruction using autologous tendon for irreparable rotator cuff tear
Frontiers in Bioengineering and Biotechnology · 13.05.2026 · 14
DOI: 10.3389/fbioe.2026.1801212 ↗Kurz gefasst
Fachartikel in der Zeitschrift Frontiers in Bioengineering and Biotechnology, online erschienen am 13.05.2026. Verfasst von Xiping Jiang und 11 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopedics, Shanghai Sixth People's Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, Shanghai, China. Die Arbeit nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Introduction
To evaluate the biomechanical and clinical outcomes of superior capsular reconstruction (SCR) with autologous tendon (AT) for the irreparable rotator cuff tears (IRCTs).
Methods
Ten fresh-frozen human upper limb specimens were used to create three models (intact, rotator cuff-deficient, and reconstruction). Superior translation of the humeral head and subacromial pressure were measured at different abduction angles under standardized loading. Mechanical comparability between tendons was also evaluated by measuring cross-sectional area and basic tensile properties. For clinical evaluation, a prospective case series of nine patients with IRCTs tears who underwent SCR with AT was conducted. Shoulder joint range of motion, American Shoulder and Elbow Surgeons (ASES), and Constant-Murley (CM) were recorded before surgery, at 6 months and 12 months after surgery. Magnetic resonance imaging (MRI) was performed preoperatively, the day after surgery, and at 6 months.
Results
The reconstruction reduced superior translation of the humeral head and subacromial pressure compared with the rotator cuff-deficient condition. No significant differences were observed in basic mechanical properties between the tested tendons. ASES scores improved significantly at both 6 and 12 months after surgery, whereas Constant score did not remain statistically significant in the 12-month pairwise comparison after adjustment for multiple comparisons. No significant differences were observed in shoulder joint range of motion. MRI showed 6/9 (67%) patients had reduced thickness of the implanted peroneus longus tendon (PLT) graft at 6 months postoperatively, while the PLT grafts of the other patients remained intact.
Conclusion
SCR with AT may help restore superior glenohumeral stability under controlled biomechanical conditions and shows promising preliminary clinical results in patients with IRCTs.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Orthopedics, Shanghai Sixth People's Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, Shanghai, China.
- Department of Orthopedics, Jinshan District Central Hospital affiliated to Shanghai University of Medicine & Health Sciences, Shanghai, China.
- Department of Orthopedics, Sichuan Provincial People's Hospital, School of Medicine, University of Electronic Science and Technology of China, Chengdu, China.
Zitieren
APA
Jiang, X., Zhang, X., Liu, P., Chen, Q., Yuan, C., Li, C., Liu, W., Song, W., Wang, X., Yu, W., Hu, Q., & He, Y. (2026). Biomechanical and clinical evaluations of superior capsular reconstruction using autologous tendon for irreparable rotator cuff tear. Frontiers in Bioengineering and Biotechnology, 14. https://doi.org/10.3389/fbioe.2026.1801212
Vancouver
Jiang X, Zhang X, Liu P, Chen Q, Yuan C, Li C, et al. Biomechanical and clinical evaluations of superior capsular reconstruction using autologous tendon for irreparable rotator cuff tear. Frontiers in Bioengineering and Biotechnology. 2026;14. doi:10.3389/fbioe.2026.1801212
BibTeX
@article{Jiang2026,
author = {Jiang, Xiping and Zhang, Xiaofeng and Liu, Pan and Chen, Qi and Yuan, Chenrui and Li, Chenkai and Liu, Wencai and Song, Wei and Wang, Xin and Yu, Weilin and Hu, Qingxiang and He, Yaohua},
title = {Biomechanical and clinical evaluations of superior capsular reconstruction using autologous tendon for irreparable rotator cuff tear},
journal = {Frontiers in Bioengineering and Biotechnology},
year = {2026},
volume = {14},
doi = {10.3389/fbioe.2026.1801212}
}
EUVIMED