High intraoperative accuracy and low complication rate of computer-assisted navigation of the glenoid in total shoulder arthroplasty
Journal of Shoulder and Elbow Surgery · 2023-06 · 32 (6) · S39-S45
DOI: 10.1016/j.jse.2022.12.021 ↗Kurz gefasst
Übersichtsarbeit in der Zeitschrift Journal of Shoulder and Elbow Surgery, 2023-06. Verfasst von Gabriel Larose und 6 weiteren Autor:innen. Beteiligte Einrichtung: Division of Shoulder and Elbow Surgery, Department of Orthopedic Surgery, NYU Langone Orthopedic Hospital, New York, NY, USA. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Shoulder, Shoulder Joint, Surgery, Computer-Assisted, Glenoid Cavity. Die Arbeit wurde bisher 52-mal zitiert (Crossref) und nennt 15 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND: Preoperative planning software with intraoperative guidance technology is increasingly being used to manage complex glenoid deformity in anatomic total shoulder arthroplasty (TSA) and reverse TSA. The aim of this study was to review the intraoperative efficacy and complications of computer-assisted navigation (CAN) surgery for the treatment of glenoid deformity in TSA. METHODS: We performed a retrospective review of all TSAs implanted using a single computer navigation shoulder system. All patients underwent preoperative planning with computed tomography-based preoperative planning software. The starting point on the glenoid and the final version and inclination of the central post (cage) of the glenoid component were reviewed on the intraoperative navigation guidance report and compared with these parameters on the preoperative plan for each patient. The intraoperative accuracy of CAN for glenoid positioning was determined by the deviation of the starting point and final position of the central cage drill in the glenoid compared with the preoperative plan. Data regarding intraoperative complications and the number of times the navigation system was abandoned intraoperatively were collected. RESULTS: A total of 16,723 anatomic TSAs and reverse TSAs performed worldwide with the aforementioned navigation system were included in this review. In 16,368 cases (98%), every step of the navigation procedure was completed without abandoning use of the system intraoperatively. There was minimal deviation in the intraoperative execution of the preoperative plan with respect to version (0.6° ± 1.96°), inclination (0.2° ± 2.04°), and the starting point on the glenoid face (1.90 ± 1.2 mm). In this cohort, 9 coracoid fractures (0.05%) were reported. CONCLUSION AND DISCUSSION: This study demonstrates the safety and efficacy of CAN for glenoid implantation in TSA. Future studies should focus on assessing the impact of CAN on the longevity and survival of glenoid components and improving the cost-effectiveness of this technology.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Division of Shoulder and Elbow Surgery, Department of Orthopedic Surgery, NYU Langone Orthopedic Hospital, New York, NY, USA.
- Exactech, Gainesville, FL, USA.
- Division of Shoulder and Elbow Surgery, Department of Orthopedic Surgery, NYU Langone Orthopedic Hospital, New York, NY, USA. Electronic address: Mandeep.virk@nyulanogne.org.
Zitieren
APA
Larose, G., Greene, A. T., Jung, A., Polakovic, S. V., Davis, N. Z., Zuckerman, J. D., & Virk, M. S. (2023). High intraoperative accuracy and low complication rate of computer-assisted navigation of the glenoid in total shoulder arthroplasty. Journal of Shoulder and Elbow Surgery, 32(6), S39-S45. https://doi.org/10.1016/j.jse.2022.12.021
Vancouver
Larose G, Greene AT, Jung A, Polakovic SV, Davis NZ, Zuckerman JD, et al. High intraoperative accuracy and low complication rate of computer-assisted navigation of the glenoid in total shoulder arthroplasty. Journal of Shoulder and Elbow Surgery. 2023;32(6):S39-S45. doi:10.1016/j.jse.2022.12.021
BibTeX
@article{Larose2023,
author = {Larose, Gabriel and Greene, Alexander T and Jung, Amaury and Polakovic, Sandrine V and Davis, Noah Z and Zuckerman, Joseph D and Virk, Mandeep S},
title = {High intraoperative accuracy and low complication rate of computer-assisted navigation of the glenoid in total shoulder arthroplasty},
journal = {Journal of Shoulder and Elbow Surgery},
year = {2023},
volume = {32},
number = {6},
pages = {S39--S45},
doi = {10.1016/j.jse.2022.12.021}
}
EUVIMED