EUVIMEDEUVIMED entdecken
Crossref

Glenoid component placement in reverse shoulder arthroplasty assisted with augmented reality through a head-mounted display leads to low deviation between planned and postoperative parameters

J Tomás Rojas, Bernhard Jost, Claudio Zipeto, Piero Budassi, Matthias A Zumstein

Journal of Shoulder and Elbow Surgery · 2023

DOI: 10.1016/j.jse.2023.05.002 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Shoulder and Elbow Surgery, 2023. Verfasst von J Tomás Rojas und 4 weiteren Autor:innen. Beteiligte Einrichtung: Shoulder, Elbow and Orthopaedic Sports Medicine, Sonnenhof Orthopaedics Center, Bern, Switzerland; Department of Orthopaedics and Trauma Surgery, Hos…. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Shoulder, Augmented Reality, Glenoid Cavity, Shoulder Joint. Die Arbeit wurde bisher 33-mal zitiert (Crossref) und nennt 31 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Navigated augmented reality (AR) through a head-mounted display (HMD) may lead to accurate glenoid component placement in reverse shoulder arthroplasty (RSA). The purpose of this study is to evaluate the deviation between planned, intra- and postoperative inclination, retroversion, entry point, depth, and rotation of the glenoid component placement assisted by a navigated AR through HMD during RSA. METHODS: Both shoulders of 6 fresh frozen human cadavers, free from fractures or other bony pathologies, were used. Preoperative computed tomography (CT) scans were used for the 3-dimensional (3D) planning. The glenoid component placement was assisted using a navigated AR system through an HMD in all specimens. Intraoperative inclination, retroversion, depth, and rotation were measured by the system. A postoperative CT scan was performed. The pre- and postoperative 3D CT scan reconstructions were superimposed to calculate the deviation between planned and postoperative inclination, retroversion, entry point, depth, and rotation of the glenoid component placement. Additionally, a comparison between intra- and postoperative values was calculated. Outliers were defined as >10° inclination, >10° retroversion, >3 mm entry point. RESULTS: The registration algorithm of the scapulae prior to the procedure was correctly completed for all cases. The deviations between planned and postoperative values were 1.0° ± 0.7° for inclination, 1.8° ± 1.3° for retroversion, 1.1 ± 0.4 mm for entry point, 0.7 ± 0.6 mm for depth, and 1.7° ± 1.6° for rotation. The deviation between intra- and postoperative values were 0.9° ± 0.8° for inclination, 1.2° ± 1.1° for retroversion, 0.6 ± 0.5 mm for depth, and 0.3° ± 0.2° for rotation. There were no outliers between planned and postoperative parameters. CONCLUSION: In this study, the use of a navigated AR system through an HMD for RSA led to low deviation between planned and postoperative values and between intra- and postoperative parameters.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, ShoulderAugmented RealityGlenoid CavityShoulder JointSmart GlassesHumansArthroplastyScapula

Stichwörter der Autor:innen

Computer-assisted reverse shoulder arthroplastyaugmented realityglenoid componenthead-mounted displaynavigated reverse shoulder arthroplastysmart glasses

Autor:innen und Institutionen

  • Shoulder, Elbow and Orthopaedic Sports Medicine, Sonnenhof Orthopaedics Center, Bern, Switzerland; Department of Orthopaedics and Trauma Surgery, Hospital San José-Clínica Santa María, Santiago, Chile.
  • Department of Orthopaedics and Trauma Surgery, Kantonsspital, Saint Gallen, Switzerland.
  • Medacta International, Castel San Pietro, Switzerland.
  • Department of Mini-invasive Orthopaedic Surgery, Humanitas Gavazzeni and Humanitas Castelli, Bergamo, Italy.
  • Shoulder, Elbow and Orthopaedic Sports Medicine, Sonnenhof Orthopaedics Center, Bern, Switzerland; Shoulder, Elbow Unit, Sportsclinicnumber1, Bern, Switzerland; Department of Orthopaedic Surgery and Traumatology, Should…

Zitieren

APA

Rojas, J. T., Jost, B., Zipeto, C., Budassi, P., & Zumstein, M. A. (2023). Glenoid component placement in reverse shoulder arthroplasty assisted with augmented reality through a head-mounted display leads to low deviation between planned and postoperative parameters. Journal of Shoulder and Elbow Surgery. https://doi.org/10.1016/j.jse.2023.05.002

Vancouver

Rojas JT, Jost B, Zipeto C, Budassi P, Zumstein MA. Glenoid component placement in reverse shoulder arthroplasty assisted with augmented reality through a head-mounted display leads to low deviation between planned and postoperative parameters. Journal of Shoulder and Elbow Surgery. 2023. doi:10.1016/j.jse.2023.05.002

BibTeX
@article{Rojas2023,
  author = {Rojas, J Tomás and Jost, Bernhard and Zipeto, Claudio and Budassi, Piero and Zumstein, Matthias A},
  title = {Glenoid component placement in reverse shoulder arthroplasty assisted with augmented reality through a head-mounted display leads to low deviation between planned and postoperative parameters},
  journal = {Journal of Shoulder and Elbow Surgery},
  year = {2023},
  doi = {10.1016/j.jse.2023.05.002}
}
Kostenlos starten →