EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Inter- and intra-site reliability of forearm sweating induced by pilocarpine iontophoresis

Hui Wang, Lu Meng, Junto Otsuka, Hanano Kato, Tatsuro Amano

The Journal of Physiological Sciences · 2026-11 · 76 (3) · 100089

DOI: 10.1016/j.jphyss.2026.100089 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Journal of Physiological Sciences, 2026-11. Verfasst von Hui Wang und 4 weiteren Autor:innen. Beteiligte Einrichtung: Laboratory for Exercise and Environmental Physiology, Faculty of Education, Niigata University, Niigata, Japan. Die Arbeit nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Japan Society for the Promotion of Science.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

We examined the inter- and intra-site reliability of pilocarpine-induced forearm sweat rate at three concentrations. Under thermoneutral conditions, 10 males and 4 females received 0.001%, 0.01%, and 1% pilocarpine via iontophoresis at the lateral and medial left forearm and the medial right forearm. Sweat rate was measured for 30 min. Inter-site (right vs. left medial) and intra-site (left lateral vs. medial) comparisons were assessed using intraclass correlation (ICC) and coefficient of variation (CV). Inter-site comparisons showed significant correlations at 0.01% and 1% (both p < 0.001, r ≥ 0.688) with good agreement (ICC ≥ 0.79, CV ≤ 21.5%), whereas 0.001% showed poorer reliability (CV = 47.3%). Intra-site reliability was highest at 1% (ICC = 0.89, CV = 16.5%) and lower at 0.01% and 0.001%. These findings indicate that inter-site comparisons of pilocarpine-induced sweating at 1% and 0.01% concentrations provide reliable responses for sweat mechanism studies (e.g., with and without antagonist administration).

Schlagwörter

Stichwörter der Autor:innen

Measurement errorReliabilitySweat rate

Autor:innen und Institutionen

  • Laboratory for Exercise and Environmental Physiology, Faculty of Education, Niigata University, Niigata, Japan.
  • Laboratory for Exercise and Environmental Physiology, Faculty of Education, Niigata University, Niigata, Japan; School of Human and Social Sciences, Fukuoka Prefectural University, Fukuoka, Japan.
  • Laboratory for Exercise and Environmental Physiology, Faculty of Education, Niigata University, Niigata, Japan. Electronic address: amano@ed.niigata-u.ac.jp.

Förderung

  • Japan Society for the Promotion of Science

Zitieren

APA

Wang, H., Meng, L., Otsuka, J., Kato, H., & Amano, T. (2026). Inter- and intra-site reliability of forearm sweating induced by pilocarpine iontophoresis. The Journal of Physiological Sciences, 76(3), 100089. https://doi.org/10.1016/j.jphyss.2026.100089

Vancouver

Wang H, Meng L, Otsuka J, Kato H, Amano T. Inter- and intra-site reliability of forearm sweating induced by pilocarpine iontophoresis. The Journal of Physiological Sciences. 2026;76(3):100089. doi:10.1016/j.jphyss.2026.100089

BibTeX
@article{Wang2026,
  author = {Wang, Hui and Meng, Lu and Otsuka, Junto and Kato, Hanano and Amano, Tatsuro},
  title = {Inter- and intra-site reliability of forearm sweating induced by pilocarpine iontophoresis},
  journal = {The Journal of Physiological Sciences},
  year = {2026},
  volume = {76},
  number = {3},
  pages = {100089},
  doi = {10.1016/j.jphyss.2026.100089}
}
Kostenlos starten →