EUVIMEDEUVIMED entdecken
Open Access

ER-detect: A pipeline for robust detection of early evoked responses in BIDS-iEEG electrical stimulation data

Max A van den Boom, Nicholas M Gregg, Gabriela Ojeda Valencia, Brian N Lundstrom, Kai J Miller, Dorien van Blooijs, Geertjan J M Huiskamp, Frans S S Leijten, Gregory A Worrell, Dora Hermes

Journal of Neuroscience Methods · 2025-06 · 418 · 110389

DOI: 10.1016/j.jneumeth.2025.110389 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Neuroscience Methods, 2025-06. Verfasst von Max A van den Boom und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN, USA; Department of Neurosurgery, Mayo Clinic, Rochester, MN, USA. Hauptthemen laut MEDLINE: Electrocorticography, Signal Processing, Computer-Assisted, Evoked Potentials, Cerebral Cortex. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 74 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIMH NIH HHS, NINDS NIH HHS, National Institute of Mental Health.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Human brain connectivity can be measured in different ways. Intracranial EEG (iEEG) measurements during single pulse electrical stimulation provide a unique way to assess the spread of electrical information with millisecond precision. However, the methods used for the detection of responses in cortico-cortical evoked potential (CCEP) data vary across studies, from visual inspection with manual annotation to a variety of automated methods. NEW METHOD: To provide a robust workflow to process CCEP data and detect early evoked responses in a fully automated and reproducible fashion, we developed the Early Response (ER)-detect toolbox. ER-detect is an open-source Python package and Docker application to preprocess BIDS structured iEEG data and detect early evoked CCEP responses. ER-detect can use three early response detection methods, which were validated against 14 manually annotated CCEP datasets from two different clinical sites by four independent raters. RESULTS AND COMPARISON WITH EXISTING METHODS: ER-detect's automated detection performed on par with the inter-rater reliability (Cohen's Kappa of ∼0.6). Moreover, ER-detect was optimized for processing large CCEP datasets, to be used in conjunction with other connectomic investigations. CONCLUSION: ER-detect provides a highly efficient standardized workflow such that iEEG-BIDS data can be processed in a consistent manner and enhance the reproducibility of CCEP based connectivity results for both research and clinical purposes.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ElectrocorticographySignal Processing, Computer-AssistedEvoked PotentialsCerebral CortexElectroencephalographyHumansElectric StimulationReproducibility of ResultsSoftware

Stichwörter der Autor:innen

Automated detection toolboxBIDSCortico-cortical evoked potential (CCEP)Early evoked responsesIntracranial EEG (iEEG)N1

Autor:innen und Institutionen

  • Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN, USA; Department of Neurosurgery, Mayo Clinic, Rochester, MN, USA.
  • Department of Neurology, Mayo Clinic, Rochester, MN, USA.
  • Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN, USA.
  • Department of Neurosurgery, Mayo Clinic, Rochester, MN, USA.
  • Department of Neurology and Neurosurgery, UMC Utrecht Brain Center, University Medical Center Utrecht, Utrecht, Netherlands; Stichting Epilepsie Instellingen Nederland (SEIN), Zwolle, Netherlands.
  • Department of Neurology and Neurosurgery, UMC Utrecht Brain Center, University Medical Center Utrecht, Utrecht, Netherlands.

Förderung

  • NIMH NIH HHS
  • NINDS NIH HHS
  • National Institute of Mental Health
  • Epilepsy Foundation
  • Mayo Clinic
  • Stichting Epilepsie Instellingen Nederland
  • National Institutes of Health

Zitieren

APA

van den Boom, M. A., Gregg, N. M., Ojeda Valencia, G., Lundstrom, B. N., Miller, K. J., van Blooijs, D., Huiskamp, G. J. M., Leijten, F. S. S., Worrell, G. A., & Hermes, D. (2025). ER-detect: A pipeline for robust detection of early evoked responses in BIDS-iEEG electrical stimulation data. Journal of Neuroscience Methods, 418, 110389. https://doi.org/10.1016/j.jneumeth.2025.110389

Vancouver

van den Boom MA, Gregg NM, Ojeda Valencia G, Lundstrom BN, Miller KJ, van Blooijs D, et al. ER-detect: A pipeline for robust detection of early evoked responses in BIDS-iEEG electrical stimulation data. Journal of Neuroscience Methods. 2025;418:110389. doi:10.1016/j.jneumeth.2025.110389

BibTeX
@article{vandenBoom2025,
  author = {van den Boom, Max A and Gregg, Nicholas M and Ojeda Valencia, Gabriela and Lundstrom, Brian N and Miller, Kai J and van Blooijs, Dorien and Huiskamp, Geertjan J M and Leijten, Frans S S and Worrell, Gregory A and Hermes, Dora},
  title = {ER-detect: A pipeline for robust detection of early evoked responses in BIDS-iEEG electrical stimulation data},
  journal = {Journal of Neuroscience Methods},
  year = {2025},
  volume = {418},
  pages = {110389},
  doi = {10.1016/j.jneumeth.2025.110389}
}
Kostenlos starten →