EUVIMEDEUVIMED entdecken
Open Access

CARLA: Adjusted common average referencing for cortico-cortical evoked potential data

Harvey Huang, Gabriela Ojeda Valencia, Nicholas M Gregg, Gamaleldin M Osman, Morgan N Montoya, Gregory A Worrell, Kai J Miller, Dora Hermes

Journal of Neuroscience Methods · 2024-07 · 407 · 110153

DOI: 10.1016/j.jneumeth.2024.110153 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Neuroscience Methods, 2024-07. Verfasst von Harvey Huang und 7 weiteren Autor:innen. Beteiligte Einrichtung: Mayo Clinic Medical Scientist Training Program, Rochester, MN, USA. Electronic address: huang.harvey@mayo.edu. Hauptthemen laut MEDLINE: Evoked Potentials, Algorithms, Cerebral Cortex, Signal Processing, Computer-Assisted. Die Arbeit wurde bisher 24-mal zitiert (Crossref) und nennt 34 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIMH NIH HHS, NIGMS NIH HHS, National Institute of Mental Health.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Human brain connectivity can be mapped by single pulse electrical stimulation during intracranial EEG measurements. The raw cortico-cortical evoked potentials (CCEP) are often contaminated by noise. Common average referencing (CAR) removes common noise and preserves response shapes but can introduce bias from responsive channels. We address this issue with an adjusted, adaptive CAR algorithm termed "CAR by Least Anticorrelation (CARLA)". CARLA was tested on simulated CCEP data and real CCEP data collected from four human participants. In CARLA, the channels are ordered by increasing mean cross-trial covariance, and iteratively added to the common average until anticorrelation between any single channel and all re-referenced channels reaches a minimum, as a measure of shared noise. We simulated CCEP data with true responses in 0-45 of 50 total channels. We quantified CARLA's error and found that it erroneously included 0 (median) truly responsive channels in the common average with ≤42 responsive channels, and erroneously excluded ≤2.5 (median) unresponsive channels at all responsiveness levels. On real CCEP data, signal quality was quantified with the mean R2 between all pairs of channels, which represents inter-channel dependency and is low for well-referenced data. CARLA re-referencing produced significantly lower mean R2 than standard CAR, CAR using a fixed bottom quartile of channels by covariance, and no re-referencing. CARLA minimizes bias in re-referenced CCEP data by adaptively selecting the optimal subset of non-responsive channels. It showed high specificity and sensitivity on simulated CCEP data and lowered inter-channel dependency compared to CAR on real CCEP data.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Evoked PotentialsAlgorithmsCerebral CortexSignal Processing, Computer-AssistedHumansMaleElectrocorticographyElectroencephalographyAdultElectric StimulationComputer SimulationFemale

Stichwörter der Autor:innen

Common average referenceCortico-cortical evoked potentialIntracranial EEGRe-referencingSingle pulse electrical stimulationStereo EEG

Autor:innen und Institutionen

  • Mayo Clinic Medical Scientist Training Program, Rochester, MN, USA. Electronic address: huang.harvey@mayo.edu.
  • Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN, USA.
  • Department of Neurology, Mayo Clinic, Rochester, MN, USA.
  • Department of Neurology, Mayo Clinic, Rochester, MN, USA; Division of Child Neurology, Department of Pediatrics, McGovern Medical School at UTHealth, Houston, TX, USA.
  • Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN, USA; Department of Neurology, Mayo Clinic, Rochester, MN, USA.
  • Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN, USA; Department of Neurologic Surgery, Mayo Clinic, Rochester, MN, USA.

Förderung

  • NIMH NIH HHS
  • NIGMS NIH HHS
  • National Institute of Mental Health
  • National Institute of General Medical Sciences
  • Mayo Clinic
  • National Institutes of Health
  • American Epilepsy Society

Zitieren

APA

Huang, H., Ojeda Valencia, G., Gregg, N. M., Osman, G. M., Montoya, M. N., Worrell, G. A., Miller, K. J., & Hermes, D. (2024). CARLA: Adjusted common average referencing for cortico-cortical evoked potential data. Journal of Neuroscience Methods, 407, 110153. https://doi.org/10.1016/j.jneumeth.2024.110153

Vancouver

Huang H, Ojeda Valencia G, Gregg NM, Osman GM, Montoya MN, Worrell GA, et al. CARLA: Adjusted common average referencing for cortico-cortical evoked potential data. Journal of Neuroscience Methods. 2024;407:110153. doi:10.1016/j.jneumeth.2024.110153

BibTeX
@article{Huang2024,
  author = {Huang, Harvey and Ojeda Valencia, Gabriela and Gregg, Nicholas M and Osman, Gamaleldin M and Montoya, Morgan N and Worrell, Gregory A and Miller, Kai J and Hermes, Dora},
  title = {CARLA: Adjusted common average referencing for cortico-cortical evoked potential data},
  journal = {Journal of Neuroscience Methods},
  year = {2024},
  volume = {407},
  pages = {110153},
  doi = {10.1016/j.jneumeth.2024.110153}
}
Kostenlos starten →