EUVIMEDEUVIMED entdecken
Open Access

Proper reference selection and re-referencing to mitigate bias in single pulse electrical stimulation data

Harvey Huang, Joshua A Adkinson, Michael A Jensen, Mohammed Hasen, Isabel A Danstrom, Kelly R Bijanki, Nicholas M Gregg, Kai J Miller, Sameer A Sheth, Dora Hermes, Eleonora Bartoli

Journal of Neuroscience Methods · 2025

DOI: 10.1016/j.jneumeth.2025.110461 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Neuroscience Methods, 2025. Verfasst von Harvey Huang und 10 weiteren Autor:innen. Beteiligte Einrichtung: Medical Scientist Training Program, Mayo Clinic, Rochester, MN, USA. Electronic address: huang.harvey@mayo.edu. Hauptthemen laut MEDLINE: Electric Stimulation, Electrocorticography, Brain, Electroencephalography. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 15 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIGMS NIH HHS, NINDS NIH HHS, NIMH NIH HHS.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Single pulse electrical stimulation experiments produce brain stimulation evoked potentials used to infer brain connectivity. The choice of recording reference for intracranial electrodes remains non-standardized and can significantly impact data interpretation. When the reference electrode is affected by stimulation or evoked brain activity, it can contaminate the brain stimulation evoked potentials recorded at all other electrodes and influence interpretation of findings. NEW METHOD: This specific issue is highlighted in intracranial EEG datasets from two subjects recorded at separate institutions. We present several intuitive metrics to detect the presence of reference contamination, based on artificial similarity between all channels. We also offer practical guidance on mitigating contamination, by switching to a more neutral reference electrode, or by post hoc re-referencing, per stimulation site, to an adjusted common average that is optimized for bias and noise. RESULTS: Either switching the reference electrode or re-referencing to an adjusted common average effectively mitigated the reference contamination issue. This was evidenced by metrics that indicated increased variability in the latencies and response durations of brain stimulation evoked potentials across the brain, and by increased similarity between experimental runs after re-referencing. CONCLUSION: Overall, this study demonstrates the necessity of clear quality checks and preprocessing steps to ensure accurate interpretation of single pulse electrical stimulation data, and it provides a set of statistics and tools to achieve this.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Electric StimulationElectrocorticographyBrainElectroencephalographyHumansEvoked PotentialsAdultBiasSignal Processing, Computer-AssistedArtifacts

Stichwörter der Autor:innen

Brain connectivityBrain stimulation evoked potentialsCortico-corticalEvoked potentialsIntracranial EEGRe-referencingSingle pulse electrical stimulationStereo-EEG

Autor:innen und Institutionen

  • Medical Scientist Training Program, Mayo Clinic, Rochester, MN, USA. Electronic address: huang.harvey@mayo.edu.
  • Department of Neurosurgery, Baylor College of Medicine, Houston, TX, USA.
  • Medical Scientist Training Program, Mayo Clinic, Rochester, MN, USA.
  • Department of Neurology, Mayo Clinic, Rochester, MN, USA.
  • Department of Neurologic Surgery, Mayo Clinic, Rochester, MN, USA.
  • Department of Neurology, Mayo Clinic, Rochester, MN, USA; Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN, USA. Electronic address: hermes.dora@mayo.edu.

Förderung

  • NIGMS NIH HHS
  • NINDS NIH HHS
  • NIMH NIH HHS
  • NEI NIH HHS
  • National Institute of General Medical Sciences
  • Mayo Clinic
  • Robert and Janice McNair Foundation
  • National Institute of Mental Health

Zitieren

APA

Huang, H., Adkinson, J. A., Jensen, M. A., Hasen, M., Danstrom, I. A., Bijanki, K. R., Gregg, N. M., Miller, K. J., Sheth, S. A., Hermes, D., & Bartoli, E. (2025). Proper reference selection and re-referencing to mitigate bias in single pulse electrical stimulation data. Journal of Neuroscience Methods. https://doi.org/10.1016/j.jneumeth.2025.110461

Vancouver

Huang H, Adkinson JA, Jensen MA, Hasen M, Danstrom IA, Bijanki KR, et al. Proper reference selection and re-referencing to mitigate bias in single pulse electrical stimulation data. Journal of Neuroscience Methods. 2025. doi:10.1016/j.jneumeth.2025.110461

BibTeX
@article{Huang2025,
  author = {Huang, Harvey and Adkinson, Joshua A and Jensen, Michael A and Hasen, Mohammed and Danstrom, Isabel A and Bijanki, Kelly R and Gregg, Nicholas M and Miller, Kai J and Sheth, Sameer A and Hermes, Dora and Bartoli, Eleonora},
  title = {Proper reference selection and re-referencing to mitigate bias in single pulse electrical stimulation data},
  journal = {Journal of Neuroscience Methods},
  year = {2025},
  doi = {10.1016/j.jneumeth.2025.110461}
}
Kostenlos starten →