EUVIMEDEUVIMED entdecken
Crossref

Effects of water hardness and cleaning agent ratio on the cleaning efficiency in medical device cleaning processes and their interaction

Shanyu Zeng

Journal of Hospital Infection · 2026-07 · 173 · 1-10

DOI: 10.1016/j.jhin.2026.03.034 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Hospital Infection, 2026-07. Verfasst von Shanyu Zeng. Beteiligte Einrichtung: Department of Disinfection Supply Center, West China School of Medicine, Sichuan University, Sichuan University affiliated Chengdu Second People's Ho…. Hauptthemen laut MEDLINE: Water, Equipment and Supplies, Disinfection. Die Arbeit nennt 28 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVE The aim of the study was to investigate the effects of water hardness and cleaning agent ratio on the cleaning efficiency of 304 stainless steel medical devices and their interaction mechanisms, providing a theoretical basis for optimizing medical device cleaning processes. METHODS Single-factor experiments and an L25(52) orthogonal design were employed to study the impact of five levels of water hardness (50-250 mg/L) and cleaning agent ratios (1:50-1:250) on cleaning efficiency. Residual soil was quantified using ultraviolet-visible (UV-Vis) spectrophotometry, surface morphology was observed via scanning electron microscopy, and cleaning efficiency was evaluated through surface tension measurements and dynamic contact angle analysis. Response surface methodology was utilized to optimize the cleaning process parameters. RESULTS As water hardness increased, cleaning efficiency significantly decreased (P < 0.05). At a water hardness of 50 mg/L, the cleaning efficiency was highest (97.5%); it dropped to 65.0% at 250 mg/L. The cleaning agent ratio exhibited an optimal value, with a 1:100 ratio achieving a cleaning efficiency of 95.0%. Analysis of variance (ANOVA) revealed that both water hardness (F = 50.23) and cleaning agent ratio (F = 30.45) significantly influenced cleaning efficiency (P < 0.001), and there was a significant interaction effect (F = 3.67, P = 0.002). Under low hardness water conditions (50-100 mg/L), the effect of cleaning agent ratio on cleaning efficiency was minimal; however, under high hardness conditions (200-250 mg/L), a higher concentration of cleaning agent was necessary to maintain cleaning efficiency. Response surface optimization indicated that a water hardness of 80 mg/L and a cleaning agent ratio of 1:120 yielded the best cleaning performance. CONCLUSION Water hardness significantly affects cleaning efficiency by influencing the effectiveness of surfactants, and there is a notable interaction between water hardness and cleaning agent ratio. Cleaning agent ratios should be appropriately adjusted based on water hardness conditions to achieve optimal cleaning efficiency. Specifically, under low hardness conditions (50-100 mg/L), cleaning agent ratios between 1:50 and 1:150 can achieve cleaning efficiency above 95%, while under high hardness conditions (200-250 mg/L), more concentrated ratios (1:50-1:100) are required to maintain acceptable cleaning efficiency. The findings of this study provide an important practical guidance for enhancing the quality of medical device cleaning and reducing operational costs.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

WaterEquipment and SuppliesDisinfectionStainless SteelSurface PropertiesMicroscopy, Electron, Scanning

Stichwörter der Autor:innen

Cleaning agent ratioInteractionMedical device cleaningResponse surface optimizationWater hardness

Substanzen

WaterStainless Steel

Autor:innen und Institutionen

  • Department of Disinfection Supply Center, West China School of Medicine, Sichuan University, Sichuan University affiliated Chengdu Second People's Hospital, Chengdu Second People's Hospital, Chengdu, Sichuan Province, 6…

Zitieren

APA

Zeng, S. (2026). Effects of water hardness and cleaning agent ratio on the cleaning efficiency in medical device cleaning processes and their interaction. Journal of Hospital Infection, 173, 1-10. https://doi.org/10.1016/j.jhin.2026.03.034

Vancouver

Zeng S. Effects of water hardness and cleaning agent ratio on the cleaning efficiency in medical device cleaning processes and their interaction. Journal of Hospital Infection. 2026;173:1-10. doi:10.1016/j.jhin.2026.03.034

BibTeX
@article{Zeng2026,
  author = {Zeng, Shanyu},
  title = {Effects of water hardness and cleaning agent ratio on the cleaning efficiency in medical device cleaning processes and their interaction},
  journal = {Journal of Hospital Infection},
  year = {2026},
  volume = {173},
  pages = {1--10},
  doi = {10.1016/j.jhin.2026.03.034}
}
Kostenlos starten →