Extraoral horizontal scan bodies (exogrammetry) for complete-arch implant rehabilitation: A proof-of-concept
Journal of Dental Implants and Prosthodontics · 2026
DOI: 10.1016/j.jdip.2026.100003 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Dental Implants and Prosthodontics, 2026. Verfasst von Gennaro Ruggiero und 4 weiteren Autor:innen. Die Arbeit nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Purpose
This proof-of-concept describes an extraoral horizontal scan body approach (exogrammetry) for registering complete-arch implant positions.
Methods
A maxillary complete-arch rehabilitation supported by 6 implants was completed at the multi-unit abutment level. Rotational GeoXact extraoral scan bodies (GeoXact; Biotec Srl, Vicenza, Italy) physically relocated the implant-reference geometries from the oral cavity to a concentrated extraoral acquisition field. A separate peri-implant soft-tissue scan was recorded with 5.5-mm MUA Scan Screws (Microimp Srl, Pordenone, Italy), which served as synchronization references for coupling the GeoXact-derived implant positions to the soft-tissue morphology. Antagonist, maxillomandibular relationship, facial, and cone beam computed tomography datasets were integrated into the virtual patient.
Results
All 6 implant positions were transferred through the extraoral geometric workflow and synchronized with the peri-implant soft-tissue dataset. A 3-dimensionally printed verification prosthesis was clinically seated, and the definitive implant-supported prosthesis was delivered without a conventional implant impression. At 6 months, the prosthesis remained stable and functional, with clinically healthy peri-implant soft tissues and no detected biological or mechanical complications.
Conclusions
The extraoral horizontal scan body approach (exogrammetry) enabled complete-arch implant-position transfer by relocating recognizable reference geometries to a concentrated extraoral scanning field. In this clinical application, the workflow also provided an implant-linked landmark field for facebow-like registration of the maxillary spatial orientation within the virtual patient. These findings support the clinical feasibility of the approach while quantitative accuracy and passive fit remain to be validated. Clinical Significance Extraoral relocation of implant-reference geometries may reduce dependence on long intraoral scanning paths and improve accessibility in posterior complete-arch situations.
Zitieren
APA
Ruggiero, G., Zara, E., Zarone, F., Jain, S., & Sorrentino, R. (2026). Extraoral horizontal scan bodies (exogrammetry) for complete-arch implant rehabilitation: A proof-of-concept. Journal of Dental Implants and Prosthodontics. https://doi.org/10.1016/j.jdip.2026.100003
Vancouver
Ruggiero G, Zara E, Zarone F, Jain S, Sorrentino R. Extraoral horizontal scan bodies (exogrammetry) for complete-arch implant rehabilitation: A proof-of-concept. Journal of Dental Implants and Prosthodontics. 2026. doi:10.1016/j.jdip.2026.100003
BibTeX
@article{Ruggiero2026,
author = {Ruggiero, Gennaro and Zara, Enrico and Zarone, Fernando and Jain, Sanjay and Sorrentino, Roberto},
title = {Extraoral horizontal scan bodies (exogrammetry) for complete-arch implant rehabilitation: A proof-of-concept},
journal = {Journal of Dental Implants and Prosthodontics},
year = {2026},
doi = {10.1016/j.jdip.2026.100003}
}
EUVIMED