Abstract (Originalsprache)
AIM or PURPOSE Accurate implant impressions are crucial for passive fit and long-term success of implant-supported prostheses. However, achieving accurate impressions in completely edentulous full-arch restorations remains challenging. Therefore, this in vitro study aimed to compare conventional and digital implant impression accuracy in an All-on-4 edentulous mandibular model and to evaluate the influence of scan body orientation on digital impressions. MATERIALS and METHODS A completely edentulous mandibular model was digitally designed using dental CAD software. Four implants were planned according to the All-on-4 treatment concept, with anterior implants placed axially and posterior implants tilted 30 degrees mesially. The fabricated model was scanned ten times and the mean reference model obtained from these scans was used as the reference model. In the conventional group, impressions were taken using an open-tray technique with elastomeric impression material. In the digital workflow, scan bodies were attached to the implants and impressions were obtained using an intraoral scanner. Digital impressions were performed with vertical and horizontal scan bodies. Each impression technique was repeated ten times. The scans were exported as STL files and superimposed with the reference dataset using best-fit alignment to evaluate three-dimensional implant positional deviations using deviation analysis software. RESULTS A total of 30 impressions were obtained across the three groups. Three-dimensional deviation analysis revealed significant differences in implant positional accuracy among the impression techniques (p
Zitieren
APA
Aşıcı, E. S., Şahin, C., & Ekinci, E. (2026). Conventional vs Digital Implant Impressions: Vertical and Horizontal Scan Bodies. International Dental Journal, 76, 110565. https://doi.org/10.1016/j.identj.2026.110565
Vancouver
Aşıcı ES, Şahin C, Ekinci E. Conventional vs Digital Implant Impressions: Vertical and Horizontal Scan Bodies. International Dental Journal. 2026;76:110565. doi:10.1016/j.identj.2026.110565
BibTeX
@article{Ac2026,
author = {Aşıcı, Elif Selen and Şahin, Cem and Ekinci, Enes},
title = {Conventional vs Digital Implant Impressions: Vertical and Horizontal Scan Bodies},
journal = {International Dental Journal},
year = {2026},
volume = {76},
pages = {110565},
doi = {10.1016/j.identj.2026.110565}
}