EUVIMEDEUVIMED entdecken
Open Access

Goniometric and 3D Motion Analysis in Shoulder ROM Assessment: A Reliability and Agreement Study Comparing Patients With Restricted Shoulder Range of Motion to Healthy Subjects

Sezen Karaşin, Yılmaz Yıldırım, Kadriye Tombak, İlhan Sezer, Özkan Köse, Umut Özsoy

Journal of Chiropractic Medicine · 2025 · 24 (1-4) · 328-336

DOI: 10.1016/j.jcm.2025.08.015 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Chiropractic Medicine, 2025. Verfasst von Sezen Karaşin und 5 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Medicine, Department of Anatomy, Akdeniz University, Antalya, Turkey. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 16 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: Akdeniz Üniversitesi.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

This study aimed to examine the reliability and agreement of goniometric measurements in assessing the range of motion (ROM) within the shoulder joint utilizing a 3D marker-based motion analysis system.

Methods

The study comprised 30 healthy volunteers and 35 patients diagnosed with unilateral restricted shoulder range of motion (ROM). Agreement analysis was conducted using Bland-Altman methods, while intra- and interobserver reliability for flexion, abduction, internal rotation, and external rotation measurements was assessed using the Intraclass Correlation Coefficient (ICC).

Results

When goniometric measurements were compared with the 3D method, ICC values in the patient group were found to be 0.85 for flexion, 0.81 for abduction, 0.80 for external rotation, and 0.74 for internal rotation. In healthy individuals, the values were found to be 0.80, 0.90, 0.56, and 0.69. Additionally, all measurements fell within acceptable limits of agreement, with no significant differences in measurement biases, except for internal rotation.

Conclusion

This study highlights that the goniometer exhibited higher reliability when assessing movements with larger ROM, particularly within heterogeneous groups like those with injured shoulders. However, its reliability decreased when used in homogeneous groups, such as healthy individuals, especially when evaluating movements with narrower ROM, such as rotations. These findings emphasize the need for a nuanced interpretation of results in clinical and research settings when assessing shoulder joint mobility.

Schlagwörter

Stichwörter der Autor:innen

BiomechanicJoint Range of MotionKinematicsShoulder Joint

Autor:innen und Institutionen

  • Faculty of Medicine, Department of Anatomy, Akdeniz University, Antalya, Turkey.
  • Vocational School of Health Services, Physiotherapy Technician Program, Akdeniz University, Antalya, Turkey.
  • Faculty of Medicine, Department of Physical Medicine and Rehabilitation, Akdeniz University, Antalya, Turkey.
  • Department of Orthopedics and Traumatology, Antalya Training and Research Hospital, Antalya, Turkey.

Förderung

  • Akdeniz Üniversitesi

Zitieren

APA

Karaşin, S., Yıldırım, Y., Tombak, K., Sezer, İ., Köse, Ö., & Özsoy, U. (2025). Goniometric and 3D Motion Analysis in Shoulder ROM Assessment: A Reliability and Agreement Study Comparing Patients With Restricted Shoulder Range of Motion to Healthy Subjects. Journal of Chiropractic Medicine, 24(1-4), 328-336. https://doi.org/10.1016/j.jcm.2025.08.015

Vancouver

Karaşin S, Yıldırım Y, Tombak K, Sezer İ, Köse Ö, Özsoy U. Goniometric and 3D Motion Analysis in Shoulder ROM Assessment: A Reliability and Agreement Study Comparing Patients With Restricted Shoulder Range of Motion to Healthy Subjects. Journal of Chiropractic Medicine. 2025;24(1-4):328-336. doi:10.1016/j.jcm.2025.08.015

BibTeX
@article{Karain2025,
  author = {Karaşin, Sezen and Yıldırım, Yılmaz and Tombak, Kadriye and Sezer, İlhan and Köse, Özkan and Özsoy, Umut},
  title = {Goniometric and 3D Motion Analysis in Shoulder ROM Assessment: A Reliability and Agreement Study Comparing Patients With Restricted Shoulder Range of Motion to Healthy Subjects},
  journal = {Journal of Chiropractic Medicine},
  year = {2025},
  volume = {24},
  number = {1-4},
  pages = {328--336},
  doi = {10.1016/j.jcm.2025.08.015}
}
Kostenlos starten →