Shoulder Range of Motion Measurement Using Inertial Measurement Unit–Concurrent Validity and Reliability
Sensors · 29.08.2023 · 23 (17) · 7499
DOI: 10.3390/s23177499 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 29.08.2023. Verfasst von Jakub Kaszyński und 3 weiteren Autor:innen. Beteiligte Einrichtung: Rehasport Clinic, Gorecka 30, 60-201 Poznan, Poland. Hauptthemen laut MEDLINE: Shoulder, Upper Extremity. Die Arbeit wurde bisher 27-mal zitiert (Crossref) und nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Centre for Research and Development, the European Union from the European Regional Development Fund under the Operational Program Smart Growth.
Abstract (Originalsprache)
This study aimed to evaluate the reliability of the RSQ Motion sensor and its validity against the Propriometer and electronic goniometer in measuring the active range of motion (ROM) of the shoulder. The study included 15 volunteers (mean age 24.73 ± 3.31) without any clinical symptoms with no history of trauma, disease, or surgery to the upper limb. Four movements were tested: flexion, abduction, external and internal rotation. Validation was assessed in the full range of active shoulder motion. Reliability was revised in full active ROM, a fixed angle of 90 degrees for flexion and abduction, and 45 degrees for internal and external rotation. Each participant was assessed three times: on the first day by both testers and on the second day only by one of the testers. Goniometer and RSQ Motion sensors showed moderate to excellent correlation for all tested movements (ICC 0.61–0.97, LOA < 23 degrees). Analysis of inter-rater reliability showed good to excellent agreement between both testers (ICC 0.74–0.97, LOA 13–35 degrees). Analysis of intra-rater reliability showed moderate to a good agreement (ICC 0.7–0.88, LOA 22–37 degrees). The shoulder internal and external rotation measurement with RSQ Motion sensors is valid and reliable. There is a high level of inter-rater and intra-rater reliability for the RSQ Motion sensors and Propriometer.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Rehasport Clinic, Gorecka 30, 60-201 Poznan, Poland.
- The Faculty of Mechanical Engineering, Institute of Applied Mechanics, Poznan University of Technology, 60-965 Poznan, Poland.
- Orthopaedics, Traumatology and Hand Surgery Department, Poznan University of Medical Sciences, 28 Czerwca 1956, No. 135/147, 61-545 Poznan, Poland.
ORCID-Profile: Jakub Kaszyński, Cezary Baka, Martyna Białecka, Przemysław Lubiatowski
Förderung
- National Centre for Research and Development
- the European Union from the European Regional Development Fund under the Operational Program Smart Growth
Zitieren
APA
Kaszyński, J., Baka, C., Białecka, M., & Lubiatowski, P. (2023). Shoulder Range of Motion Measurement Using Inertial Measurement Unit–Concurrent Validity and Reliability. Sensors, 23(17), 7499. https://doi.org/10.3390/s23177499
Vancouver
Kaszyński J, Baka C, Białecka M, Lubiatowski P. Shoulder Range of Motion Measurement Using Inertial Measurement Unit–Concurrent Validity and Reliability. Sensors. 2023;23(17):7499. doi:10.3390/s23177499
BibTeX
@article{Kaszyski2023,
author = {Kaszyński, Jakub and Baka, Cezary and Białecka, Martyna and Lubiatowski, Przemysław},
title = {Shoulder Range of Motion Measurement Using Inertial Measurement Unit–Concurrent Validity and Reliability},
journal = {Sensors},
year = {2023},
volume = {23},
number = {17},
pages = {7499},
doi = {10.3390/s23177499}
}
EUVIMED