Reliability and Validity of the Single-Camera Markerless Motion Capture System for Measuring Shoulder Range of Motion in Healthy Individuals and Patients with Adhesive Capsulitis: A Single-Center Study
Sensors · 21.03.2025 · 25 (7) · 1960
DOI: 10.3390/s25071960 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 21.03.2025. Verfasst von Suji Lee und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Acupuncture and Moxibustion Medicine, Kyung Hee University Medical Center, Seoul 02447, Republic of Korea. Hauptthemen laut MEDLINE: Bursitis, Range of Motion, Articular, Shoulder Joint, Shoulder. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Korea Health Industry Development Institute, Ministry of Health & Welfare, Republic of Korea.
Abstract (Originalsprache)
Assessing shoulder joint range of motion (ROM) is essential for diagnosing musculoskeletal disorders and optimizing treatments. This single-center pilot study evaluated the reliability and validity of iBalance, a single-camera markerless motion capture system, for measuring shoulder ROM. Forty participants (30 healthy individuals and 10 patients with adhesive capsulitis) underwent measurements of seven shoulder joint movements. Each movement was assessed three times by two raters using both iBalance and a goniometer, with measurements repeated after 1 week. The iBalance demonstrated excellent inter- and intra-rater reliability for flexion (ICC = 0.93 [0.91–0.95], 0.91 [0.88–0.94]), abduction (ICC = 0.97 [0.95–0.98], 0.93 [0.91–0.95]), and passive abduction (ICC = 0.97 [0.96–0.98], 0.98 [0.97–0.98]). The system also showed strong validity compared to the goniometer for flexion (ICC = 0.85 [0.68–0.92]), abduction (ICC = 0.95 [0.94–0.96]), and passive abduction (ICC = 0.97 [0.96–0.98]). Bland–Altman plots showed high consistency between the two devices for flexion, abduction, and passive abduction, with most data points falling within the limits of agreement. Patients with adhesive capsulitis exhibited greater variability than healthy individuals. No adverse events were reported, supporting the safety of the system. This study highlights the potential of a single-camera markerless motion capture system for diagnosing and treating shoulder joint disorders. The iBalance showed clinical applicability for measuring flexion, abduction, and passive abduction. Future enhancements to the algorithm and the incorporation of advanced metrics could improve its performance, facilitating broader clinical applications for diagnosing complex shoulder conditions.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Acupuncture and Moxibustion Medicine, Kyung Hee University Medical Center, Seoul 02447, Republic of Korea.
- Department of Acupuncture and Moxibustion, College of Korean Medicine, Kyung Hee University, Seoul 05278, Republic of Korea.
- 20th Fighter Wing, Republic of Korea Air Force, Seosan 32024, Republic of Korea.
- Department of Clinical Korean Medicine, Graduate School, Kyung Hee University, Seoul 02447, Republic of Korea.
ORCID-Profile: Suji Lee, Unhyung Lee, Yohwan Kim, Seungjin Noh, Hungu Lee, Seunghoon Lee
Förderung
- Korea Health Industry Development Institute
- Ministry of Health & Welfare, Republic of Korea
Zitieren
APA
Lee, S., Lee, U., Kim, Y., Noh, S., Lee, H., & Lee, S. (2025). Reliability and Validity of the Single-Camera Markerless Motion Capture System for Measuring Shoulder Range of Motion in Healthy Individuals and Patients with Adhesive Capsulitis: A Single-Center Study. Sensors, 25(7), 1960. https://doi.org/10.3390/s25071960
Vancouver
Lee S, Lee U, Kim Y, Noh S, Lee H, Lee S. Reliability and Validity of the Single-Camera Markerless Motion Capture System for Measuring Shoulder Range of Motion in Healthy Individuals and Patients with Adhesive Capsulitis: A Single-Center Study. Sensors. 2025;25(7):1960. doi:10.3390/s25071960
BibTeX
@article{Lee2025,
author = {Lee, Suji and Lee, Unhyung and Kim, Yohwan and Noh, Seungjin and Lee, Hungu and Lee, Seunghoon},
title = {Reliability and Validity of the Single-Camera Markerless Motion Capture System for Measuring Shoulder Range of Motion in Healthy Individuals and Patients with Adhesive Capsulitis: A Single-Center Study},
journal = {Sensors},
year = {2025},
volume = {25},
number = {7},
pages = {1960},
doi = {10.3390/s25071960}
}