EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY-NC-ND 4.0

Real-World Outcomes for the Fifth-Generation Balloon Expandable Transcatheter Heart Valve in the United States

Curtiss T Stinis, Amr E Abbas, Paul Teirstein, Raj R Makkar, Christine J Chung, Vijay Iyer, Philippe Généreux, Robert M Kipperman, John K Harrison, G Chad Hughes, Jefferson M Lyons, Ayaz Rahman und 10 weitere

JACC: Cardiovascular Interventions · 2024-04 · 17 (8) · 1032-1044

DOI: 10.1016/j.jcin.2024.02.015 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift JACC: Cardiovascular Interventions, 2024-04. Verfasst von Curtiss T Stinis und 21 weiteren Autor:innen. Beteiligte Einrichtung: Division of Cardiology, Scripps Clinic, La Jolla, California, USA. Electronic address: STINIS.CURTISS@SCRIPPSHEALTH.ORG. Hauptthemen laut MEDLINE: Aortic Valve, Aortic Valve Stenosis, Balloon Valvuloplasty, Heart Valve Prosthesis. Die Arbeit wurde bisher 70-mal zitiert (Crossref) und nennt 14 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: The fifth-generation SAPIEN 3 Ultra Resilia valve (S3UR) incorporates several design changes as compared with its predecessors, the SAPIEN 3 (S3) and SAPIEN 3 Ultra (S3U) valves, including bovine leaflets treated with a novel process intended to reduce structural valve deterioration via calcification, as well as a taller external skirt on the 29-mm valve size to reduce paravalvular leak (PVL). The clinical performance of S3UR compared with S3 and S3U in a large patient population has not been previously reported. OBJECTIVES: The aim of this study was to compare S3UR to S3/S3U for procedural, in-hospital, and 30-day clinical and echocardiographic outcomes after transcatheter aortic valve replacement (TAVR). METHODS: Patients enrolled in the STS/ACC TVT (Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy) Registry between January 1, 2021, and June 30, 2023, who underwent TAVR with S3UR or S3U/S3 valve platforms were propensity-matched and evaluated for procedural, in-hospital, and 30-day clinical and echocardiographic outcomes. RESULTS: 10,314 S3UR patients were propensity matched with 10,314 patients among 150,539 S3U/S3 patients. At 30 days, there were no statistically significant differences in death, stroke, or bleeding, but a numerically higher hospital readmission rate in the S3UR cohort (8.5% vs 7.7%; P = 0.04). At discharge, S3UR patients exhibited significantly lower mean gradients (9.2 ± 4.6 mm Hg vs 12.0 ± 5.7 mm Hg; P < 0.0001) and larger aortic valve area (2.1 ± 0.7 cm2 vs 1.9 ± 0.6 cm2; P < 0.0001) than patients treated with S3/S3U. The 29-mm valve size exhibited significant reduction in mild PVL (5.3% vs 9.4%; P < 0.0001). CONCLUSIONS: S3UR TAVR is associated with lower mean gradients and lower rates of PVL than earlier generations of balloon expandable transcatheter heart valve platforms.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Aortic ValveAortic Valve StenosisBalloon ValvuloplastyHeart Valve ProsthesisProsthesis DesignRecovery of FunctionRegistriesTranscatheter Aortic Valve ReplacementAgedAged, 80 and overFemaleHumansMaleHemodynamicsPostoperative ComplicationsRetrospective StudiesRisk AssessmentRisk FactorsTime FactorsTreatment OutcomeUnited States

Stichwörter der Autor:innen

bioprosthesesheart valve prosthesispropensity scoretranscatheter aortic valve replacement

Autor:innen und Institutionen

  • Division of Cardiology, Scripps Clinic, La Jolla, California, USA. Electronic address: STINIS.CURTISS@SCRIPPSHEALTH.ORG.
  • Corewell Health East, William Beaumont University Hospital, Royal Oak, Michigan, USA.
  • Division of Cardiology, Scripps Clinic, La Jolla, California, USA.
  • Cedars-Sinai Medical Center, Los Angeles, California, USA.
  • University of Washington Medical Center, Department of Medicine, Division of Cardiology, Seattle, Washington, USA.
  • Jacobs School of Medicine and Biomedical Sciences, University at Buffalo, Buffalo, New York, New York, USA.

Zitieren

APA

Stinis, C. T., Abbas, A. E., Teirstein, P., Makkar, R. R., Chung, C. J., Iyer, V., Généreux, P., Kipperman, R. M., Harrison, J. K., Hughes, G. C., Lyons, J. M., Rahman, A., Kakouros, N., Walker, J., Roberts, D. K., Huang, P. H., Kar, B., Dhoble, A., Logsdon, D. P., …, & McCabe, J. M. (2024). Real-World Outcomes for the Fifth-Generation Balloon Expandable Transcatheter Heart Valve in the United States. JACC: Cardiovascular Interventions, 17(8), 1032-1044. https://doi.org/10.1016/j.jcin.2024.02.015

Vancouver

Stinis CT, Abbas AE, Teirstein P, Makkar RR, Chung CJ, Iyer V, et al. Real-World Outcomes for the Fifth-Generation Balloon Expandable Transcatheter Heart Valve in the United States. JACC: Cardiovascular Interventions. 2024;17(8):1032-1044. doi:10.1016/j.jcin.2024.02.015

BibTeX
@article{Stinis2024,
  author = {Stinis, Curtiss T and Abbas, Amr E and Teirstein, Paul and Makkar, Raj R and Chung, Christine J and Iyer, Vijay and Généreux, Philippe and Kipperman, Robert M and Harrison, John K and Hughes, G Chad and Lyons, Jefferson M and Rahman, Ayaz and Kakouros, Nikolaos and Walker, Jennifer and Roberts, David K and Huang, Pei-Hsiu and Kar, Biswajit and Dhoble, Abhijeet and Logsdon, Daniel P and Khanna, Puneet K and Aragon, Joseph and McCabe, James M},
  title = {Real-World Outcomes for the Fifth-Generation Balloon Expandable Transcatheter Heart Valve in the United States},
  journal = {JACC: Cardiovascular Interventions},
  year = {2024},
  volume = {17},
  number = {8},
  pages = {1032--1044},
  doi = {10.1016/j.jcin.2024.02.015}
}
Kostenlos starten →