EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Test–retest stability and angle-specific characteristics of dynamically assessed trunk gravity compensation in isokinetic testing

Sebastian Puschkasch-Möck, Lina Hofmann, Christian Günther, Stanislav Dimitri Siegel, Konstantin Warneke

Journal of Biomechanics Open · 2026

DOI: 10.1016/j.jbmo.2026.100018 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Biomechanics Open, 2026. Verfasst von Sebastian Puschkasch-Möck und 4 weiteren Autor:innen. Die Arbeit nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Dynamic gravity compensation is routinely applied in isokinetic trunk testing to account for segmental weight across the range of motion. However, the test–retest stability and angle-specific characteristics of this device-based compensation procedure remain unclear. This study investigated (1) the between-session stability of dynamically assessed trunk gravity compensation and (2) angle-specific differences between compensation performed with and without inclusion of the participant's trunk. Fifty-one field hockey athletes completed three isokinetic trunk flexion and extension sessions using an ISOMED2000 dynamometer. During the first two sessions, gravity compensation was performed including the trunk; during the third session, compensation was performed using the lever arm only. Compensation torque curves were extracted from raw and compensated torque signals and compared using statistical parametric mapping. Peak torque and the angle of peak torque were additionally analyzed. For trunk extension, compensation curves and peak torque values showed high between-session stability and minimal angle-specific differences between compensation procedures. In contrast, trunk flexion demonstrated significant angle-specific differences in compensation torque, which were reflected in altered torque profiles, peak torque values, and peak torque angles. These findings indicate that dynamically assessed trunk gravity compensation is stable for extension but exhibits angle-dependent variability in flexion. Standardized and clearly reported compensation procedures appear particularly important for trunk flexion testing to ensure methodological consistency.

Zitieren

APA

Puschkasch-Möck, S., Hofmann, L., Günther, C., Siegel, S. D., & Warneke, K. (2026). Test–retest stability and angle-specific characteristics of dynamically assessed trunk gravity compensation in isokinetic testing. Journal of Biomechanics Open. https://doi.org/10.1016/j.jbmo.2026.100018

Vancouver

Puschkasch-Möck S, Hofmann L, Günther C, Siegel SD, Warneke K. Test–retest stability and angle-specific characteristics of dynamically assessed trunk gravity compensation in isokinetic testing. Journal of Biomechanics Open. 2026. doi:10.1016/j.jbmo.2026.100018

BibTeX
@article{PuschkaschMck2026,
  author = {Puschkasch-Möck, Sebastian and Hofmann, Lina and Günther, Christian and Siegel, Stanislav Dimitri and Warneke, Konstantin},
  title = {Test–retest stability and angle-specific characteristics of dynamically assessed trunk gravity compensation in isokinetic testing},
  journal = {Journal of Biomechanics Open},
  year = {2026},
  doi = {10.1016/j.jbmo.2026.100018}
}
Kostenlos starten →