Inconclusive Single-Lead ECGs From Smart-Devices

Corinne Isenegger, Diego Mannhart, Simon Weidlich, Jonas Brügger, Teodor Serban, Fabian Jordan, Philipp Krisai, Sven Knecht, Nicolas Schaerli, Behnam Subin, Luke Mosher, Jeanne du Fay de Lavallaz und 5 weitere

JACC: Clinical Electrophysiology · 2025-09 · 11 (9) · 2003-2011

DOI: 10.1016/j.jacep.2025.04.027 ↗

Kurz gefasst

Fachartikel in der Zeitschrift JACC: Clinical Electrophysiology, 2025-09. Verfasst von Corinne Isenegger und 16 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, University Hospital Basel, Basel, Switzerland; Cardiovascular Research Institute Basel, University Hospital Basel, Universi…. Hauptthemen laut MEDLINE: Electrocardiography, Wearable Electronic Devices, Arrhythmias, Cardiac. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 15 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Multiple smart devices can record single-lead electrocardiograms (SL-ECGs) with automated rhythm classification. The impact of pre-existing baseline ECG anomalies on the accuracy of automated rhythm classification remains largely unknown. OBJECTIVES: This study sought to compare the presence of predefined ECG anomalies and their impact on rhythm classification ability of 5 commercially available FDA and CE-marked wearable smart-devices. METHODS: This prospective study included consecutive patients undergoing electrophysiological procedures at a tertiary referral center. Each participant obtained a 12-lead ECG followed by SL-ECGs with 5 different smart devices (AliveCor KardiaMobile, Apple Watch 6, Fitbit Sense, Samsung Galaxy Watch 3, and Withings ScanWatch). Two independent cardiologists performed manual rhythm classification and assessed the following ECG anomalies: ventricular pacing, conduction delay, low voltage, artifacts, and premature atrial or ventricular complexes. RESULTS: A total of 256 participants were included (29% female, mean age 66 years) generating 1,280 recorded SL-ECGs. Of these, 242 SL-ECGs (19%) were classified as inconclusive by at least 1 smart device. The presence of any ECG anomaly was significantly higher in inconclusive vs conclusive SL-ECGs, with 74% vs 42%; P < 0.001. ORs with 95% CIs for inconclusive classification by ECG anomaly were ventricular pacing 6.35 [3.84-10.61], conduction delay 2.42 [1.82-3.22], low voltage 2.37 [1.75-3.21], minor artifact 1.72 [1.17-2.51], major artifact 10.62 [6.78-16.99], premature atrial complex 2.23 [1.29-3.74], and premature ventricular complex 1.94 [1.29-2.89]. Notable differences were found between the assessed smart devices. CONCLUSIONS: Automated rhythm classification is highly susceptible to baseline ECG anomalies. This study provides insights into the most appropriate patient population for smart device-based arrhythmia monitoring and offers guidance for selecting the optimal smart device tailored to individual patient characteristics.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ElectrocardiographyWearable Electronic DevicesArrhythmias, CardiacHumansFemaleMaleProspective StudiesAgedMiddle AgedAged, 80 and over

Stichwörter der Autor:innen

atrial fibrillationinconclusivesmart devicesmartwatch

Autor:innen und Institutionen

  • Department of Cardiology, University Hospital Basel, Basel, Switzerland; Cardiovascular Research Institute Basel, University Hospital Basel, University of Basel, Basel, Switzerland.
  • Department of Cardiology, University Hospital Basel, Basel, Switzerland; Cardiovascular Research Institute Basel, University Hospital Basel, University of Basel, Basel, Switzerland. Electronic address: patrick.badertsch…

Zitieren

APA

Isenegger, C., Mannhart, D., Weidlich, S., Brügger, J., Serban, T., Jordan, F., Krisai, P., Knecht, S., Schaerli, N., Subin, B., Mosher, L., du Fay de Lavallaz, J., Schaer, B., Mahfoud, F., Kühne, M., Sticherling, C., & Badertscher, P. (2025). Inconclusive Single-Lead ECGs From Smart-Devices. JACC: Clinical Electrophysiology, 11(9), 2003-2011. https://doi.org/10.1016/j.jacep.2025.04.027

Vancouver

Isenegger C, Mannhart D, Weidlich S, Brügger J, Serban T, Jordan F, et al. Inconclusive Single-Lead ECGs From Smart-Devices. JACC: Clinical Electrophysiology. 2025;11(9):2003-2011. doi:10.1016/j.jacep.2025.04.027

BibTeX
@article{Isenegger2025,
  author = {Isenegger, Corinne and Mannhart, Diego and Weidlich, Simon and Brügger, Jonas and Serban, Teodor and Jordan, Fabian and Krisai, Philipp and Knecht, Sven and Schaerli, Nicolas and Subin, Behnam and Mosher, Luke and du Fay de Lavallaz, Jeanne and Schaer, Beat and Mahfoud, Felix and Kühne, Michael and Sticherling, Christian and Badertscher, Patrick},
  title = {Inconclusive Single-Lead ECGs From Smart-Devices},
  journal = {JACC: Clinical Electrophysiology},
  year = {2025},
  volume = {11},
  number = {9},
  pages = {2003--2011},
  doi = {10.1016/j.jacep.2025.04.027}
}
Kostenlos starten →