Long-Term Safety and Efficacy of Intraoperative Leadless Pacemaker Implantation During Valve Surgery
JACC: Clinical Electrophysiology · 2024
DOI: 10.1016/j.jacep.2024.06.018 ↗Kurz gefasst
Fachartikel in der Zeitschrift JACC: Clinical Electrophysiology, 2024. Verfasst von Connor P Oates und 17 weiteren Autor:innen. Beteiligte Einrichtung: Helmsley Electrophysiology Center, Department of Cardiology, Icahn School of Medicine at Mount Sinai, New York, New York, USA. Hauptthemen laut MEDLINE: Pacemaker, Artificial. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 14 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND: Intraoperative implantation of leadless cardiac pacemakers (LCPs) under direct visualization during cardiac surgery is a novel strategy to provide pacing to patients with an elevated risk of postoperative conduction disorders or with a preexisting pacing indication undergoing valve surgery. OBJECTIVES: This study sought to evaluate the long-term safety and efficacy of intraoperative LCP implantation in 100 consecutive patients. METHODS: Retrospective single-center cohort study of consecutive patients (n = 100) who underwent intraoperative LCP implantation during valve surgery. Safety and efficacy were assessed at implantation and follow-up visits. RESULTS: A total of 100 patients (age 68 ± 13 years, 47% female) underwent intraoperative LCP implantation. The surgery involved the tricuspid valve in 99 patients (99%), including tricuspid valve repair in 59 (59%) and tricuspid valve replacement in 40 (40%). Most of the patients (78%) underwent multivalve surgery. The indication for LCP implantation was elevated risk of postoperative atrioventricular block in 54% and preexisting bradyarrhythmias in 46%. LCP implantation was successful in all patients. During a median of 10.6 months (IQR: 2.0-22.7 months) of follow-up, no device-related complications occurred. At 12-month follow-up, the pacing thresholds were acceptable (≤2.0 V at 0.24 milliseconds) in 95% of patients. CONCLUSIONS: Intraoperative LCP implantation under direct visualization is a safe strategy to provide permanent pacing in patients undergoing valve surgery, with a postoperative electrical performance comparable to percutaneously placed LCPs.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Helmsley Electrophysiology Center, Department of Cardiology, Icahn School of Medicine at Mount Sinai, New York, New York, USA.
- Helmsley Electrophysiology Center, Department of Cardiology, Icahn School of Medicine at Mount Sinai, New York, New York, USA; Department of Cardiology, Amsterdam UMC Location AMC, Amsterdam, the Netherlands.
- Helmsley Electrophysiology Center, Department of Cardiology, Icahn School of Medicine at Mount Sinai, New York, New York, USA. Electronic address: marc.miller@mssm.edu.
- Department of Cardiovascular Surgery, Icahn School of Medicine at Mount Sinai, New York, New York, USA.
- Department of Anesthesiology, Icahn School of Medicine at Mount Sinai, New York, New York, USA.
Zitieren
APA
Oates, C. P., Breeman, K. T. N., Miller, M. A., Boateng, P., Patil, A., Musikantow, D. R., Williams, E., El-Hamamsy, I., Montgomery, M. L., Salter, B. S., Rimsukcharoenchai, C., Pandis, D., Weiner, M. M., Dukkipati, S. R., Anyanwu, A., Reddy, V. Y., Adams, D. H., & El-Eshmawi, A. M. (2024). Long-Term Safety and Efficacy of Intraoperative Leadless Pacemaker Implantation During Valve Surgery. JACC: Clinical Electrophysiology. https://doi.org/10.1016/j.jacep.2024.06.018
Vancouver
Oates CP, Breeman KTN, Miller MA, Boateng P, Patil A, Musikantow DR, et al. Long-Term Safety and Efficacy of Intraoperative Leadless Pacemaker Implantation During Valve Surgery. JACC: Clinical Electrophysiology. 2024. doi:10.1016/j.jacep.2024.06.018
BibTeX
@article{Oates2024,
author = {Oates, Connor P and Breeman, Karel T N and Miller, Marc A and Boateng, Percy and Patil, Aarti and Musikantow, Daniel R and Williams, Elbert and El-Hamamsy, Ismail and Montgomery, Morgan L and Salter, Benjamin S and Rimsukcharoenchai, Chartaroon and Pandis, Dimosthenis and Weiner, Menachem M and Dukkipati, Srinivas R and Anyanwu, Anelechi and Reddy, Vivek Y and Adams, David H and El-Eshmawi, Ahmed M},
title = {Long-Term Safety and Efficacy of Intraoperative Leadless Pacemaker Implantation During Valve Surgery},
journal = {JACC: Clinical Electrophysiology},
year = {2024},
doi = {10.1016/j.jacep.2024.06.018}
}
EUVIMED