Physics Considerations for Evaluation of Dose for Dose-Response Models of Pediatric Late Effects From Radiation Therapy: A PENTEC Introductory Review
International Journal of Radiation Oncology*Biology*Physics · 2024
DOI: 10.1016/j.ijrobp.2023.02.060 ↗Kurz gefasst
Übersichtsarbeit in der Zeitschrift International Journal of Radiation Oncology*Biology*Physics, 2024. Verfasst von Arthur J Olch und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology, University of Southern California and Children's Hospital Los Angeles, Los Angeles, California. Electronic address:…. Hauptthemen laut MEDLINE: Dose-Response Relationship, Radiation, Neoplasms, Organs at Risk, Radiation Injuries. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 26 Literaturangaben. Gefördert von: Cancer Research UK.
Abstract (Originalsprache)
PURPOSE: We describe the methods used to estimate the accuracy of dosimetric data found in literature sources used to construct the Pediatric Normal Tissue Effects in the Clinic (PENTEC) dose-response models, summarize these findings of each organ-specific task force, describe some of the dosimetric challenges and the extent to which these efforts affected the final modeling results, and provide guidance on the interpretation of the dose-response results given the various dosimetric uncertainties. METHODS AND MATERIALS: Each of the PENTEC task force medical physicists reviewed all the journal articles used for dose-response modeling to identify, categorize, and quantify dosimetric uncertainties. These uncertainties fell into 6 broad categories. A uniform nomenclature was developed for describing the "dosimetric quality" of the articles used in the PENTEC reviews. Among the multidisciplinary experts in the PENTEC effort, the medical physicists were charged with the dosimetric evaluation, as they are most expert in this subject. RESULTS: The percentage dosimetric uncertainty was estimated for each late effect endpoint for all PENTEC organ reports. Twelve specific sources of dose uncertainty were identified related to the 6 broad categories. The most common reason for organ dose uncertainty was that prescribed dose rather than organ dose was reported. Percentage dose uncertainties ranged from 5% to 200%. Systematic uncertainties were used to correct the dose component of the models. Random uncertainties were also described in each report and in some cases used to modify dose axis error bars. In addition, the potential effects of dose binning were described. CONCLUSIONS: PENTEC reports are designed to provide guidance to radiation oncologists and treatment planners for organ dose constraints. It is critical that these dose constraint recommendations are as accurate as possible, acknowledging the large error bars for many. Achieving this accuracy is important as it enables clinicians to better balance target dose coverage with risk of late effects. Evidence-based dose constraints for pediatric patients have been lacking and, in this regard, PENTEC fills an important unmet need. One must be aware of the limitations of our recommendations, and that for some organ systems, large uncertainties exist in the dose-response model because of clinical endpoint uncertainty, dosimetric uncertainty, or both.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Radiation Oncology, University of Southern California and Children's Hospital Los Angeles, Los Angeles, California. Electronic address: aolch@chla.usc.edu.
- Department of Radiation Oncology, University Medical Center Groningen, University of Groningen, The Netherlands.
- Department of Radiation Oncology, St. Jude Children's Research Hospital, Memphis, Tennessee.
- Department of Medical Physics, Centro di Riferimento Oncologico di Aviano (CRO) IRCCS, Aviano, Italy.
- Department of Radiation Physics, University of Texas MD Anderson Cancer Center, Houston, Texas.
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, New York.
Förderung
- Cancer Research UK
Zitieren
APA
Olch, A. J., van Luijk, P., Hua, C. H., Avanzo, M., Howell, R. M., Yorke, E., Aznar, M. C., & Kry, S. F. (2024). Physics Considerations for Evaluation of Dose for Dose-Response Models of Pediatric Late Effects From Radiation Therapy: A PENTEC Introductory Review. International Journal of Radiation Oncology*Biology*Physics. https://doi.org/10.1016/j.ijrobp.2023.02.060
Vancouver
Olch AJ, van Luijk P, Hua CH, Avanzo M, Howell RM, Yorke E, et al. Physics Considerations for Evaluation of Dose for Dose-Response Models of Pediatric Late Effects From Radiation Therapy: A PENTEC Introductory Review. International Journal of Radiation Oncology*Biology*Physics. 2024. doi:10.1016/j.ijrobp.2023.02.060
BibTeX
@article{Olch2024,
author = {Olch, Arthur J and van Luijk, Peter and Hua, Chia-Ho and Avanzo, Michele and Howell, Rebecca M and Yorke, Ellen and Aznar, Marianne C and Kry, Stephen F},
title = {Physics Considerations for Evaluation of Dose for Dose-Response Models of Pediatric Late Effects From Radiation Therapy: A PENTEC Introductory Review},
journal = {International Journal of Radiation Oncology*Biology*Physics},
year = {2024},
doi = {10.1016/j.ijrobp.2023.02.060}
}
EUVIMED