EUVIMEDEUVIMED entdecken
Crossref

A Combined Dose and Microdosimetric Modeling Framework Incorporating Volume Effects Correlates with Tissue Sparing in Proton Minibeam Radiation Therapy

G Bordieri, M Missiaggia, M Battestini, G Lattanzi, F Romano, E Scifoni, F G Cordoni

International Journal of Radiation Oncology*Biology*Physics · 2026-09

DOI: 10.1016/j.ijrobp.2026.09.007 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Journal of Radiation Oncology*Biology*Physics, 2026-09. Verfasst von G Bordieri und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Physics, University of Trento, Trento, Italy; Trento Institute for Fundamental Physics and Application (TIFPA), Trento, Italy. Hauptthemen laut MEDLINE: Proton Therapy, Organs at Risk, Organ Sparing Treatments, Radiation Injuries. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 40 Literaturangaben. Gefördert von: INFN.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: Proton minibeam (pMB) radiation therapy delivers highly heterogeneous dose distributions, alternating high-dose peaks and low-dose valleys. This aims to widen the therapeutic window by improving normal tissue sparing while maintaining the same or even better tumor control. The performance of pMB strongly depends on the collimator design and physical parameters. To better understand the physical and radiobiological drivers of this enhanced therapeutic window, we perform a detailed microdosimetric characterization of pMBs and assess their impact. METHODS AND MATERIALS: We characterize radiation quality with microdosimetry through Monte Carlo simulations. Then we extend the Generalized Stochastic Microdosimetric Model (GSM2) to predict the normal tissue complication probability (NTCP) at different depths in water, 1, 2, and 4 cm, for 100-MeV pMBs realized with varying configurations of the collimator. Results are compared with conventional homogeneous field irradiation after dose normalization to the tumor. The developed model is applied by considering tissues as divided into several functional subunits, connected by introducing a seriality parameter. RESULTS: Microdosimetric characterization of pMB irradiation shows differences between peak and valley regions in shaping lineal energy spectra, especially at low depth, whereas radiation quality uniforms progressively closer to the target region (tumor). NTCP calculation results suggest an increased sparing effect for pMB over conventional homogeneous field. A strong dependence is found on the peak-to-valley dose ratio and on the seriality parameter. Predictions indicate substantial sparing from pMB, especially for peak-to-valley dose ratio > 15, including relatively serial organs with seriality around 0.7. All results are consistent with the general trends reported in experimental studies. CONCLUSIONS: This integrated dose-microdosimetric-biological framework elucidates how spatial fractionation, radiation quality, and organ architecture collectively shape tissue sparing in pMB. The findings identify conditions under which pMB may offer NTCP reduction, highlighting the importance of incorporating microdosimetry and tissue seriality in future optimization and clinical translation efforts.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Proton TherapyOrgans at RiskOrgan Sparing TreatmentsRadiation InjuriesRadiometryModels, BiologicalMonte Carlo MethodRadiotherapy DosageHumansStochastic Processes

Autor:innen und Institutionen

  • Department of Physics, University of Trento, Trento, Italy; Trento Institute for Fundamental Physics and Application (TIFPA), Trento, Italy.
  • Trento Institute for Fundamental Physics and Application (TIFPA), Trento, Italy; Department of Physics & Astronomy, Louisiana State University (LSU), Baton Rouge, Louisiana. Electronic address: mmissi2@lsu.edu.
  • Istituto Nazionale Fisica Nucleare (INFN), Sezione di Catania, Catania, Italy.
  • Trento Institute for Fundamental Physics and Application (TIFPA), Trento, Italy.
  • Trento Institute for Fundamental Physics and Application (TIFPA), Trento, Italy; Department of Civil, Environmental and Mechanical Engineering, University of Trento, Trento, Italy; Department of Civil and Environmental…

Förderung

  • INFN

Zitieren

APA

Bordieri, G., Missiaggia, M., Battestini, M., Lattanzi, G., Romano, F., Scifoni, E., & Cordoni, F. G. (2026). A Combined Dose and Microdosimetric Modeling Framework Incorporating Volume Effects Correlates with Tissue Sparing in Proton Minibeam Radiation Therapy. International Journal of Radiation Oncology*Biology*Physics. https://doi.org/10.1016/j.ijrobp.2026.09.007

Vancouver

Bordieri G, Missiaggia M, Battestini M, Lattanzi G, Romano F, Scifoni E, et al. A Combined Dose and Microdosimetric Modeling Framework Incorporating Volume Effects Correlates with Tissue Sparing in Proton Minibeam Radiation Therapy. International Journal of Radiation Oncology*Biology*Physics. 2026. doi:10.1016/j.ijrobp.2026.09.007

BibTeX
@article{Bordieri2026,
  author = {Bordieri, G and Missiaggia, M and Battestini, M and Lattanzi, G and Romano, F and Scifoni, E and Cordoni, F G},
  title = {A Combined Dose and Microdosimetric Modeling Framework Incorporating Volume Effects Correlates with Tissue Sparing in Proton Minibeam Radiation Therapy},
  journal = {International Journal of Radiation Oncology*Biology*Physics},
  year = {2026},
  doi = {10.1016/j.ijrobp.2026.09.007}
}
Kostenlos starten →