Fachartikel in der Zeitschrift Technology in Cancer Research & Treatment, 2026. Verfasst von Allison Haertter und 7 weiteren Autor:innen. Beteiligte Einrichtung: New York Proton Center, New York, NY. Hauptthemen laut MEDLINE: Radiotherapy Planning, Computer-Assisted, Radiotherapy, Intensity-Modulated, Whole-Body Irradiation, Lung. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: GE Healthcare.
Abstract (Originalsprache)
Introduction
Halcyon™ O-ring linear accelerators (linacs) provide a robust and efficient radiotherapy option for clinics. Interest in volumetric arc therapy (VMAT) based total body irradiation (TBI) has grown, with most current VMAT TBI protocols employing C-arm linacs; however, the feasibility of Halcyon-based VMAT TBI has been recently hypothesized. This study investigates the planning feasibility and dosimetric quality of VMAT-based, lung-sparing TBI delivered by Halcyon linac to pediatric patients.
Methods
10 pediatric patients (94 – 134 cm in height) previously treated to 12 Gy TBI through traditional 3D planning techniques were retrospectively replanned on a Halcyon linac. 2-3 VMAT plans containing 4-6 isocenters each with 2-2.5 arcs were created to treat the head, abdomen, and legs, with 1-2 static-gantry treatment matching areas being used between VMAT planning regions.
Results
Lung doses were significantly reduced below the clinically significant level of 8 Gy, achieving mean doses of 6.66 ± 0.52 Gy (55.5% ± 4.3%). Target coverage was achieved with D90% of 77.5% ± 12.5% and homogeneity indexes of 0.92 ± 0.1. Planning time took 5-6 hours per patient: 1.5 hours for contouring and field placement and 3.5-4.5 hours for plan optimization and dose calculations. Using a dose rate of 800 MU/min field delivery time took an average of 20.8 ± 7 minutes with average portal dosimetry quality assurance passing rates of 99.6% and 99.9% for 2%/2mm and 3%/3mm gamma analysis metrics.
Conclusion
VMAT lung sparing TBI via Halcyon linacs is feasible and dosimetrically acceptable, with greatest applicability to smaller patients (100 cm) due to the smaller maximum field sizes (28 x 28 cm2) achievable. Future developments in software-based automations for target delineation, multiple field matching, and plan optimization could allow for more practicable treatment of larger patients.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- New York Proton Center, New York, NY.
- Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA.
- Department of Radiation Oncology, University of Pennsylvania, Philadelphia, PA.
- Department of Radiation Oncology, Children's Hospital of Philadelphia, University of Pennsylvania, Philadelphia, PA.
ORCID-Profile: Keshav Goel
Förderung
- GE Healthcare
Zitieren
APA
Haertter, A., Goel, K., Niculcea, J., Li, T., Hill-Kayser, C. E., Plastaras, J., LaRiviere, M. J., & Kim, M. M. (2026). Dosimetric Performance Analysis of Pediatric Based Halcyon™ Volumetric Arc Therapy-Based Lung-Sparing Total Body Irradiation. Technology in Cancer Research & Treatment. https://doi.org/10.1177/15330338261443068
Vancouver
Haertter A, Goel K, Niculcea J, Li T, Hill-Kayser CE, Plastaras J, et al. Dosimetric Performance Analysis of Pediatric Based Halcyon™ Volumetric Arc Therapy-Based Lung-Sparing Total Body Irradiation. Technology in Cancer Research & Treatment. 2026. doi:10.1177/15330338261443068
BibTeX
@article{Haertter2026,
author = {Haertter, Allison and Goel, Keshav and Niculcea, Jacob and Li, Taoran and Hill-Kayser, Christine E and Plastaras, John and LaRiviere, Michael J and Kim, Michele M},
title = {Dosimetric Performance Analysis of Pediatric Based Halcyon™ Volumetric Arc Therapy-Based Lung-Sparing Total Body Irradiation},
journal = {Technology in Cancer Research & Treatment},
year = {2026},
doi = {10.1177/15330338261443068}
}
EUVIMED