Efficacy of non-compliant balloon post-dilation in optimization of contemporary stents: A digital stent enhancement study

Jaya Chandrasekhar, Christopher Allada, Simon O'Connor, Moyazur Rahman, Bruce Shadbolt, Ahmad Farshid

IJC Heart & Vessels · 2014

DOI: 10.1016/j.ijchv.2014.03.006 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IJC Heart & Vessels, 2014. Verfasst von Jaya Chandrasekhar und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, The Canberra Hospital, Australia. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 3.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: There is no evidence from randomized trials for the benefit of routine non-compliant balloon (NCB) post-dilation after stent deployment. Despite being the gold standard, intravascular ultrasound is infrequently performed due to time and cost constraints and a suitable alternative technology is required for routine assessment of stent expansion. The purpose of this study was to assess the contribution of NCB post-dilation in optimizing contemporary stents by using digital stent enhancement (DSE). METHODS: We treated 120 patients with stent insertion and assessed the stents with DSE before and after NCB use. Optimal expansion was defined as the minimum stent diameter (MSD) ≥ 90% of the nominal stent diameter, an adaptation of the MUSIC and POSTIT trial criteria. Stent deployment was performed at 12 atm pressure followed by routine NCB post-dilation at ≥ 14 atm. RESULTS: The mean reference diameter on QCA was 2.75 mm (SD 0.63) and mean stent diameter was 3.15 mm (SD 0.46). At a mean stent deployment pressure of 11.7 atm (SD 2.4), only 21% of stents were optimally expanded. After NCB inflation at a mean of 16.9 atm (SD 2.8), MSD increased by 0.26 mm (SD 0.24), optimal stent expansion increased from 21% to 58% and mean stent symmetry ratio increased from 0.83 to 0.87 (p < 0.0001). CONCLUSIONS: Contemporary stents are sub-optimally expanded in the majority of cases after standard deployment compared with nominal sizes. Adjunctive NCB post-dilation optimized an additional 37% of stents. DSE analysis can assist in qualitative and quantitative stent assessments and can potentially facilitate a selective NCB post-dilation strategy to achieve optimal stent expansion.

Schlagwörter

Stichwörter der Autor:innen

Digital stent enhancementNon-compliant balloonOptimal stent deploymentPercutaneous coronary interventionQuantitative coronary angiographyStent expansion

Autor:innen und Institutionen

  • Department of Cardiology, The Canberra Hospital, Australia.
  • Centre for Advances in Epidemiology and Information Technology, The Canberra Hospital, Australia.

Zitieren

APA

Chandrasekhar, J., Allada, C., O'Connor, S., Rahman, M., Shadbolt, B., & Farshid, A. (2014). Efficacy of non-compliant balloon post-dilation in optimization of contemporary stents: A digital stent enhancement study. IJC Heart & Vessels. https://doi.org/10.1016/j.ijchv.2014.03.006

Vancouver

Chandrasekhar J, Allada C, O'Connor S, Rahman M, Shadbolt B, Farshid A. Efficacy of non-compliant balloon post-dilation in optimization of contemporary stents: A digital stent enhancement study. IJC Heart & Vessels. 2014. doi:10.1016/j.ijchv.2014.03.006

BibTeX
@article{Chandrasekhar2014,
  author = {Chandrasekhar, Jaya and Allada, Christopher and O'Connor, Simon and Rahman, Moyazur and Shadbolt, Bruce and Farshid, Ahmad},
  title = {Efficacy of non-compliant balloon post-dilation in optimization of contemporary stents: A digital stent enhancement study},
  journal = {IJC Heart & Vessels},
  year = {2014},
  doi = {10.1016/j.ijchv.2014.03.006}
}
Kostenlos starten →