Abstract (Originalsprache)

Aims

Embedded transpapillary self-expandable metal stents (SEMS) often lead to obstructive biliary complications. Endoscopic extraction is generally required and standard approaches often fail. In the current study we describe a newly developed approach to treating refractory embedded SEMS, using balloon dilation-assisted stent extraction or 'BASE'. Our aim was to evaluate the feasibility and outcomes of this technique.

Methods

This is an exploratory single-center retrospective analysis and all consecutive patients undergoing endoscopic balloon-assisted stent extraction were included. During this procedure, a 15mm through-the-scope dilation balloon is inflated in the embedded SEMS and distal bile duct, after which the SEMS and dilation device are both extracted simultaneously by firm continuous traction. Baseline, procedural and follow-up data were collected and analyzed. The AGREE-classification was used for adverse event grading.

Results

Twelve patients with embedded transpapillary SEMS were identified (60.0% female, mean age 70.1 [SD±18.1] years, uncovered SEMS 33.3%) with median SEMS dwell time of 457.5 (IQR 175.8-1042) days. Previous extraction attempts were undertaken in the majority of cases (83.3%), including forceps traction (58.3%) and SEMS-in-SEMS placement (41.7%). Using the balloon-assisted stent extraction or ‘BASE’ technique, successful SEMS extraction was achieved in 10 out of 12 cases (83.3%). Adverse events occurred in 2 patients (Grade I [n=1, 8.3%] – Grade II [n=1, 8.3%]), consisting both of immediate postprocedure episodes of cholangitis, which were both treated successfully with antibiotics. After a median follow-up time of 171 (58-260) days, one biliary re-obstruction occurred for which endoscopic re-evaluation and a negative balloon sweep was performed.

Conclusions

Our data suggest that endoscopic balloon-assisted stent extraction or ‘BASE’ could be considered for extraction of embedded self-expandable metal stents, as it showed high efficacy without any major procedure-related adverse events, using readily available endoscopic tools. Publication History Article published online: 15 April 2024 © 2024. European Society of Gastrointestinal Endoscopy. All rights reserved. Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany

Zitieren

APA

Bronswijk, M., Reekmans, A., & Merwe, S. V. D. (2024). Balloon Dilation-assisted Extraction of Embedded Biliary Self-Expandable Metal Stents: A Proof-of-Concept Study. Endoscopy, 56(S 02 S 02), S263-S264. https://doi.org/10.1055/s-0044-1783309

Vancouver

Bronswijk M, Reekmans A, Merwe SVD. Balloon Dilation-assisted Extraction of Embedded Biliary Self-Expandable Metal Stents: A Proof-of-Concept Study. Endoscopy. 2024;56(S 02 S 02):S263-S264. doi:10.1055/s-0044-1783309

BibTeX
@article{Bronswijk2024,
  author = {Bronswijk, M. and Reekmans, A. and Merwe, S. Van der},
  title = {Balloon Dilation-assisted Extraction of Embedded Biliary Self-Expandable Metal Stents: A Proof-of-Concept Study},
  journal = {Endoscopy},
  year = {2024},
  volume = {56},
  number = {S 02 S 02},
  pages = {S263--S264},
  doi = {10.1055/s-0044-1783309}
}