Effect of Horizontal and Vertical Intraoral Scan Bodies on the Trueness of Complete‐Arch Digital Implant Impressions: A Comparative In Vitro Study With Six Implants
Clinical Oral Implants Research · 2025-09 · 36 (9) · 1136-1145
DOI: 10.1111/clr.14463 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Clinical Oral Implants Research, online erschienen am 11.06.2025. Verfasst von Luís Azevedo und 6 weiteren Autor:innen. Beteiligte Einrichtung: Division of Fixed Prosthodontics and Biomaterials, University Clinics for Dental Medicine, University of Geneva, Geneva, Switzerland. Hauptthemen laut MEDLINE: Dental Impression Technique, Dental Implants, Computer-Aided Design. Die Arbeit wurde bisher 23-mal zitiert (Crossref) und nennt 47 Literaturangaben.
Abstract (Originalsprache)
Objective
To evaluate the interaction between intraoral scan body (ISB) type, operator, and intraoral scanner (IOS) selection on the trueness of complete‐arch digital implant impressions. This study also compared horizontal ISBs (H‐ISBs) and vertical ISBs (V‐ISBs) across four IOS devices. Material and Methods Digital impressions of a definitive mandibular cast with six multi‐unit analogs were made using four H‐ISBs from different manufacturers (denoted as H‐NB, H‐NS, H‐M6, and H‐SF), with a V‐ISB (V‐EA) as the reference. Each ISB was scanned using a desktop scanner and by two operators who scanned each ISB system 10 times using four IOS devices i5D, PS, T3, T4, generating 400 digital impressions. Deviations were measured using root‐mean‐square (RMS) error ( α = 0.05).
Results
All independent variables (operator, IOS, ISB) significantly affected trueness ( p < 0.05). V‐EA with i5D had the lowest trueness (78 [27] μm), while H‐NS on PS showed the highest (12 [3] μm). H‐M6 maintained high trueness across IOS devices. PS was the most stable IOS, while T4 showed the most variability.
Conclusions
Complete‐arch digital impressions are influenced by ISBs, IOSs, and operators. H‐ISBs demonstrated better trueness and consistency across IOSs and operators.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Division of Fixed Prosthodontics and Biomaterials, University Clinics for Dental Medicine, University of Geneva, Geneva, Switzerland.
- Center for Interdisciplinary Research in Health, The Catholic University of Portugal (UCP), Viseu, Portugal.
- Department of Chemical Science and Technologies, University of Rome Tor Vergata, Rome, Italy.
- Faculty of Dental Medicine, The Catholic University of Portugal (UCP), Viseu, Portugal.
- Department of Clinical Science and Translational Medicine, University of Rome Tor Vergata, Rome, Italy.
- Goldstein Center for Esthetic and Implant Dentistry, Department of Restorative Science, The Dental College of Georgia at Augusta University, Augusta, Georgia, USA.
ORCID-Profile: Luís Azevedo, João Pitta, Irena Sailer
Zitieren
APA
Azevedo, L., Laureti, A., Marques, T., Pitta, J., Fehmer, V., Pozzi, A., & Sailer, I. (2025). Effect of Horizontal and Vertical Intraoral Scan Bodies on the Trueness of Complete‐Arch Digital Implant Impressions: A Comparative In Vitro Study With Six Implants. Clinical Oral Implants Research, 36(9), 1136-1145. https://doi.org/10.1111/clr.14463
Vancouver
Azevedo L, Laureti A, Marques T, Pitta J, Fehmer V, Pozzi A, et al. Effect of Horizontal and Vertical Intraoral Scan Bodies on the Trueness of Complete‐Arch Digital Implant Impressions: A Comparative In Vitro Study With Six Implants. Clinical Oral Implants Research. 2025;36(9):1136-1145. doi:10.1111/clr.14463
BibTeX
@article{Azevedo2025,
author = {Azevedo, Luís and Laureti, Andrea and Marques, Tiago and Pitta, João and Fehmer, Vincent and Pozzi, Alessandro and Sailer, Irena},
title = {Effect of Horizontal and Vertical Intraoral Scan Bodies on the Trueness of Complete‐Arch Digital Implant Impressions: A Comparative In Vitro Study With Six Implants},
journal = {Clinical Oral Implants Research},
year = {2025},
volume = {36},
number = {9},
pages = {1136--1145},
doi = {10.1111/clr.14463}
}
EUVIMED