Digital vs Conventional Full‐Arch Implant Impressions: A Retrospective Analysis of 36 Edentulous Jaws
Journal of Prosthodontics · 2023-04 · 32 (4) · 325-330
DOI: 10.1111/jopr.13536 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Prosthodontics, online erschienen am 31.05.2022. Verfasst von Panos Papaspyridakos und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Prosthodontics, Tufts University School of Dental Medicine, Boston, MA. Hauptthemen laut MEDLINE: Dental Implants, Jaw, Edentulous. Die Arbeit wurde bisher 64-mal zitiert (Crossref) und nennt 26 Literaturangaben.
Abstract (Originalsprache)
Purpose
There is a paucity of comparative clinical studies assessing the accuracy of full‐arch digital scans versus conventional implant impressions. The aim of this retrospective study was to compare the three‐dimensional (3D) deviations between full‐arch digital scans and conventional implant impressions for edentulous maxillae and mandibles. Materials and methods Twenty‐seven patients (36 edentulous jaws) were treated with one‐piece, screw‐retained implant‐supported fixed complete dental prostheses (IFCDPs). Twenty‐one jaws were maxillary, and 15 were mandibular. Full‐arch conventional impressions and intraoral digital scans with scan bodies and an intraoral scanner had been taken during the impression phase. Following verification of the conventional stone casts, the casts were digitized. The generated standard tessellation language (STL) files from both impression techniques were merged and analyzed with reverse engineering software. The primary aim was to evaluate the accuracy between conventional and digital full‐arch scans, while the effect of the edentulous jaw in 3D accuracy was the secondary aim.
Results
The cumulative 3D (mean ± SD) deviations between virtual casts from intraoral full‐arch digital scans and digitized stone casts generated from conventional implant impressions were found to be 88 ±24 μm. In the maxillary group, the mean ± SD 3D deviation was 85 ±25 μm, compared to 92 ±23 μm for the mandibular group ( p = 0.444).
Conclusion
The 3D implant deviations found between the full‐arch digital and conventional impressions lie within the clinically acceptable threshold. No statistically significant difference was identified between maxillary and mandibular jaws in terms of 3D deviations.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Prosthodontics, Tufts University School of Dental Medicine, Boston, MA.
- Department of Prosthodontics, University of Rochester Eastman Institute for Oral Health, Rochester, NY.
- Department of Public Health, Tufts University School of Dental Medicine, Boston, MA.
ORCID-Profile: Panos Papaspyridakos, Andre De Souza, Elena Sicilia, Sotirios Gotsis, Yo-Wei Chen, Konstantinos Vazouras, Konstantinos Chochlidakis
Zitieren
APA
Papaspyridakos, P., De Souza, A., Finkelman, M., Sicilia, E., Gotsis, S., Chen, Y. W., Vazouras, K., & Chochlidakis, K. (2023). Digital vs Conventional Full‐Arch Implant Impressions: A Retrospective Analysis of 36 Edentulous Jaws. Journal of Prosthodontics, 32(4), 325-330. https://doi.org/10.1111/jopr.13536
Vancouver
Papaspyridakos P, De Souza A, Finkelman M, Sicilia E, Gotsis S, Chen YW, et al. Digital vs Conventional Full‐Arch Implant Impressions: A Retrospective Analysis of 36 Edentulous Jaws. Journal of Prosthodontics. 2023;32(4):325-330. doi:10.1111/jopr.13536
BibTeX
@article{Papaspyridakos2023,
author = {Papaspyridakos, Panos and De Souza, Andre and Finkelman, Matthew and Sicilia, Elena and Gotsis, Sotirios and Chen, Yo-Wei and Vazouras, Konstantinos and Chochlidakis, Konstantinos},
title = {Digital vs Conventional Full‐Arch Implant Impressions: A Retrospective Analysis of 36 Edentulous Jaws},
journal = {Journal of Prosthodontics},
year = {2023},
volume = {32},
number = {4},
pages = {325--330},
doi = {10.1111/jopr.13536}
}
EUVIMED