Comparison of the Accuracy and Clinical Applications of Different Scanners

Elif Pilatin

International Dental Journal · 2026-10 · 76 · 110548

DOI: 10.1016/j.identj.2026.110548 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Dental Journal, 2026-10. Verfasst von Elif Pilatin. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

AIM or PURPOSE The aims of this study were to evaluate the accuracy of wired and wireless devices, compare scanning and data processing times, and assess their clinical impact, including differences between experienced and inexperienced clinicians. The results are intended to support device selection and optimize the use of digital workflows in clinical practice. MATERIALS and METHODS For this study, 10 mandibular and 10 maxillary cast models that had previously mounted on articulators were utilized. Each stone models was scanned five times by an operator with experienced and inexperienced clinicians. In this study, the scanning and data processing times, the overall accuracy assessed through three dimensional point deviations obtained from predetermined landmarks on the upper and lower jaw models and compared using RMS values and the local accuracy evaluated by measuring and comparing the horizontal and vertical linear distances between fixed reference points on the upper and lower arches obtained from bite registration were statistically analyzed. RESULTS The results demonstrated no operator- or scanner-related differences in linear bite registration measurements, while clinical experience significantly reduced scanning time. Wireless Dexis IS3800 showed longer scanning and processing times, whereas AlliedStar scanners exhibited comparable time performance, with scanner-dependent variations in trueness and precision between maxillary and mandibular arches. CONCLUSIONS Statistically significant differences were observed between wired and wireless intraoral scanners in terms of trueness and precision deviation values. Additionally, scanning and data processing times demonstrated significant variations associated with both operator experience and scanner performance.

Zitieren

APA

Pilatin, E. (2026). Comparison of the Accuracy and Clinical Applications of Different Scanners. International Dental Journal, 76, 110548. https://doi.org/10.1016/j.identj.2026.110548

Vancouver

Pilatin E. Comparison of the Accuracy and Clinical Applications of Different Scanners. International Dental Journal. 2026;76:110548. doi:10.1016/j.identj.2026.110548

BibTeX
@article{Pilatin2026,
  author = {Pilatin, Elif},
  title = {Comparison of the Accuracy and Clinical Applications of Different Scanners},
  journal = {International Dental Journal},
  year = {2026},
  volume = {76},
  pages = {110548},
  doi = {10.1016/j.identj.2026.110548}
}
Kostenlos starten →