EUVIMEDEUVIMED entdecken
Crossref

The Effect of Different Intraoral Scanners on The Accuracy of Bite Registration in Edentulous Maxillary and Mandibular Arches.

Vygandas Rutkūnas, Darius Jegelevičius, Agnė Gedrimienė, Liudas Auškalnis, Eyüboğlu, Tan Fırat, Mutlu Özcan, Nadin Al‐Haj Husain, Mykolas Akulauskas, Justinas Pletkus

Open Access CRIS of the University of Bern · 01.07.2024

DOI: 10.48350/196716 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Open Access CRIS of the University of Bern, erschienen am 01.07.2024. Verfasst von Vygandas Rutkūnas und 9 weiteren Autor:innen.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVES The objective of this study was to use in vitro models to examine the bite registration accuracy of four different intraoral scanners (IOS) for edentulous maxillary and mandibular arches. The objective was to assess the trueness and precision of the IOS and determine if there were significant differences between them. METHODS An Asiga Max UV 3D printer was used to print maxillary and mandibular edentulous models based on the shape of Frasaco models (artificial dental arch models). Four dental implants were placed symmetrically in both models using Straumann BLT RC implants. Digital impressions were taken with Primescan, Trios 3, Trios 4, and Medit i500 intraoral scanners (n = 10 for each IOS). Digital bite registrations were made, and scanning data was exported in STL format. The accuracy of the interarch distance (the distance between the metrological spheres attached to the mandibular and maxillary models) was estimated for each IOS. RESULTS The results showed significant differences in trueness and precision between different IOS (p .05). Primescan provided the most accurate results, followed by Medit i500, Trios 3, and Trios 4, respectively. CONCLUSIONS within the limitations of this study, the IOS type affects the accuracy of interocclusal bite registration in in vitro design. Only Primescan achieved clinically acceptable accuracy for the interocclusal recording of edentulous arches. CLINICAL RELEVANCE The comparison of the accuracy of bite registration between different intraoral scanners will help increase the efficiency of the clinical application of digitalized interarch registration.

Schlagwörter

intraoral scannersbite registrationedentulous archinterocclusal registrationdigital impressionstrueness and precisionPrimescanTRIOS 3Trios 4dental implants

Zitieren

APA

Rutkūnas, V., Jegelevičius, D., Gedrimienė, A., Auškalnis, L., Eyüboğlu, Fırat, T., Özcan, M., Husain, N. A., Akulauskas, M., & Pletkus, J. (2024). The Effect of Different Intraoral Scanners on The Accuracy of Bite Registration in Edentulous Maxillary and Mandibular Arches. Open Access CRIS of the University of Bern. https://doi.org/10.48350/196716

Vancouver

Rutkūnas V, Jegelevičius D, Gedrimienė A, Auškalnis L, Eyüboğlu, Fırat T, et al. The Effect of Different Intraoral Scanners on The Accuracy of Bite Registration in Edentulous Maxillary and Mandibular Arches. Open Access CRIS of the University of Bern. 2024. doi:10.48350/196716

BibTeX
@article{Rutknas2024,
  author = {Rutkūnas, Vygandas and Jegelevičius, Darius and Gedrimienė, Agnė and Auškalnis, Liudas and Eyüboğlu and Fırat, Tan and Özcan, Mutlu and Husain, Nadin Al‐Haj and Akulauskas, Mykolas and Pletkus, Justinas},
  title = {The Effect of Different Intraoral Scanners on The Accuracy of Bite Registration in Edentulous Maxillary and Mandibular Arches},
  journal = {Open Access CRIS of the University of Bern},
  year = {2024},
  doi = {10.48350/196716}
}
Kostenlos starten →