EUVIMEDEUVIMED entdecken
Crossref

Electrogram-guided Bachmann bundle area pacing to correct interatrial block: Initial experience, safety, and feasibility

Muthiah Subramanian, Sachin Yalagudri, Daljeet Saggu, Jasvinder Singh, Dinakar Bootla, Preetam Krishnamoorthy, Sridevi Chennapragda, Calambur Narasimhan

Heart Rhythm · 2025-04 · 22 (4) · 1064-1070

DOI: 10.1016/j.hrthm.2024.08.024 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Heart Rhythm, 2025-04. Verfasst von Muthiah Subramanian und 7 weiteren Autor:innen. Beteiligte Einrichtung: AIG Institute of Cardiac Sciences, Hyderabad, India. Hauptthemen laut MEDLINE: Cardiac Pacing, Artificial, Bundle of His, Interatrial Block, Electrophysiologic Techniques, Cardiac. Die Arbeit wurde bisher 25-mal zitiert (Crossref) und nennt 14 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: A lack of standard Bachmann bundle (BB) capture criteria has affected the clinical impact of Bachmann bundle area pacing (BBAP) in patients with interatrial block (IAB). OBJECTIVE: The purpose of this study was to evaluate the feasibility and safety of electrogram-guided Bachmann bundle pacing (BBP) using sheath assisted, stylet-driven atrial lead implantation. METHODS: Patients with baseline IAB undergoing dual-chamber pacemaker or implantable cardioverter-defibrillator implantation were enrolled in a single-center prospective study. BBAP was attempted in all patients using a Selectra 3D S-40 delivery sheath and Solia S-60 pacing lead. BB capture was confirmed using a combination of fluoroscopy, P-wave morphology, and electrophysiological criteria. These included recording of a high-frequency BB potential and transition between nonselective and selective BB capture during threshold testing. Procedure-related complications, lead parameters, and P-wave morphology were assessed at implantation and follow-up. RESULTS: Permanent BBAP was successful in 32 of the 36 enrolled patients (88.9%). Baseline P-wave duration was 148.5 ± 16.1 ms. Among patients who underwent successful BBP, final paced P-wave duration was 117.8 ± 19.6ms. Correction of partial or complete IAB occurred in 22 patients (91.7%) and 6 patients (75.0%), respectively. BB potentials were recorded in 83.3% of all study patients. Transition from NS to S BB capture could be demonstrated during threshold testing in 22 patients (87.5%). The only major complications were 2 BBAP lead dislodgments within 24 hours and a rise in pacing impedance at 3 weeks in 1 patient. CONCLUSION: BBAP is feasible in a high percentage of patients and is associated with stable capture thresholds during follow-up.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Cardiac Pacing, ArtificialBundle of HisInteratrial BlockElectrophysiologic Techniques, CardiacHumansMaleFemaleFeasibility StudiesProspective StudiesAgedTreatment OutcomeFollow-Up StudiesElectrocardiographyMiddle Aged

Stichwörter der Autor:innen

Atrial resynchronization therapyBachmann bundle potentialInteratrial conduction delayStylet-driven lead implantationbachmann bundle pacing

Autor:innen und Institutionen

  • AIG Institute of Cardiac Sciences, Hyderabad, India.
  • AIG Institute of Cardiac Sciences, Hyderabad, India. Electronic address: calambur1@gmail.com.

Zitieren

APA

Subramanian, M., Yalagudri, S., Saggu, D., Singh, J., Bootla, D., Krishnamoorthy, P., Chennapragda, S., & Narasimhan, C. (2025). Electrogram-guided Bachmann bundle area pacing to correct interatrial block: Initial experience, safety, and feasibility. Heart Rhythm, 22(4), 1064-1070. https://doi.org/10.1016/j.hrthm.2024.08.024

Vancouver

Subramanian M, Yalagudri S, Saggu D, Singh J, Bootla D, Krishnamoorthy P, et al. Electrogram-guided Bachmann bundle area pacing to correct interatrial block: Initial experience, safety, and feasibility. Heart Rhythm. 2025;22(4):1064-1070. doi:10.1016/j.hrthm.2024.08.024

BibTeX
@article{Subramanian2025,
  author = {Subramanian, Muthiah and Yalagudri, Sachin and Saggu, Daljeet and Singh, Jasvinder and Bootla, Dinakar and Krishnamoorthy, Preetam and Chennapragda, Sridevi and Narasimhan, Calambur},
  title = {Electrogram-guided Bachmann bundle area pacing to correct interatrial block: Initial experience, safety, and feasibility},
  journal = {Heart Rhythm},
  year = {2025},
  volume = {22},
  number = {4},
  pages = {1064--1070},
  doi = {10.1016/j.hrthm.2024.08.024}
}